PROPANE PRACTICE TESTS QUESTIONS &
ANSWERS
According to the Two Permanent Openings Method one opening must commence within
____ and one must commence within ___ of the enclosure - Answers :12 inches of the
top 12 inches of the bottom

Room heaters shall NOT be installed in what occupancies? - Answers :Health care and
Residential board and care.

Define a type B-W gas vent: - Answers :It shall not have a listed capacity NOT LESS
than that of the listed vented wall furnace to which it is connected.

Listed vented wall furnaces shall use which type of venting system? - Answers :Type B-
W gas vent

NO portion of a venting system shall extend or pass through any.... - Answers
:Fabricated air duct OR Furnace plenum

Type 1 and Type 2 clothes dryers shall be exhausted to the ________. - Answers
:Outside

Ventilating hoods and exhaust systems shall be ________ installed in commercial
applications and to vent industrial equipment. - Answers :Permitted to vent gas
appliances

What appliances are NOT required to be vented? - Answers :Counter appliances or
Direct gas-fired make-up air heaters

What is the correct spacing of supports for 3/4" or 1" steel pipe? - Answers :Every 8 feet

Regarding indoor combustion air, what method states the minimum volume shall be 50
cube feet per 1000 Btu/hour? - Answers :Standard method

All dispensers shall be installed on what type of foundation? - Answers :Concrete

The number of containers in a building undergoing minor renovations shall NOT exceed
the ________ assigned to using the LP-gas. - Answers :Number of workers and shall
not exceed ______ lbs in size

Aboveground containers shall be ________. - Answers :Painted

All regulators for outdoor installations shall be designed, _______ or protected so that
operation will not be affected by the elements. - Answers :Installed

,The exit terminals of mechanical draft systems shall not be LESS than ___________
when located adjacent to public walkways. - Answers :7 ft above finished ground level

Forced draft systems and all portions of induced draft systems under positive pressure
during operation shall be designed and installed so as to _____________. - Answers
:Prevent leakage of flue gases into the building

Mechanical draft systems shall be _______ . - Answers :Listed

A chimney for residential type or low heat appliances shall extend at least 2 feet higher
than any portion of a building within a horizontal distance of _______. - Answers :10
feet

Category I Vented appliance - Answers :An appliance that operates with a non-positive
vent static pressure and with a vent gas temperature that avoids excessive condensate
production in the vent.

Temperature sensitive elements of emergency shutoff valves shall NOT be ________ . -
Answers :Painted

In a piping system where condensation of vapor can occur, piping shall be _______, or
means shall be provided for re-vaporizing the condensate. - Answers :sloped back to
the container

What is the minimum cover that should be maintained over all underground metallic
piping? - Answers :12 inches

Polyethylene piping systems shall be limited to vapor service not exceeding ________. -
Answers :30 psig

A listed __________ shall be installed at the discharge end of the transfer hose at
vehicle fuel dispensers. - Answers :Quick-acting shutoff valve

Metallic pipe joints shall be permitted to be ____________ using proper pipe and
fittings. - Answers :Welded or Brazed

Flexible metallic connectors shall NOT exceed _________ in overall length when used
with liquid or vapor piping on stationary containers of 2000 gallon w.c. or less. -
Answers :5 feet

Hose length at a motor fuel dispensing station may NOT exceed _____________
unless approved by AHJ. - Answers :18 feet

, Unlisted air-conditioning appliances shall be installed with clearances from combustible
material of NOT less than ____________ above the appliance and at the sides, front,
and rear. - Answers :18 inches

The _______ employed for operating the automatic main gas control valve, automatic
pilot, room temperature thermostat, limit control, other electrical devices used with the
appliances shall be in accordance with the wiring diagrams certified or approved by the
original appliance manufacturer. - Answers :Electrical circuit

The sediment trap shall be installed as close to the inlet of the equipment as practical at
the ___________. - Answers :Time of equipment installation

With regard to the indoor use of nonmetallic gas hose connectors, an equipment shutoff
valve shall be installed where the connector is ________. - Answers :Attached to the
building piping

The cross-sectional area of the common vent shall be _______________ the cross-
sectional area of the largest connector. - Answers :Equal to or greater than

Appliances and equipment shall be furnished either with load distributing bases or with
a sufficient number of ________ to prevent damage to either the building structure or
the appliance and the equipment. - Answers :Supports

___________ shall be located so as NOT to interfere with proper circulation of
combustion, ventilation, and dilution air. - Answers :Appliances

All air handled by a non-circulating direct gas-fired industrial air heaters shall be
___________. - Answers :Ducted directly from outdoors

Gas piping serving heating gas appliances shall be permitted to also serve
_____________ where heating and cooling equipment cannot be operated
simultaneously. - Answers :Cooling equipment

Equipment connected to a piping systemshall have an accessible approved manual
shutoff valve with a ___________. - Answers :Non-displaceable valve member

Steam and hot water boilers, shall be provided with approved ___________ for shutting
down the burner to prevent boiler steam pressure exceeding the maximum allowable
working pressure or temperature. - Answers :Automatic limiting devices

A vertical distance of NOT less than ______ shall be provided between the top of all
food service hot plates and griddles and combustible material. - Answers :48 inches

Listed floor-mounted food service equipment, such as restaraunts, shall be installed at
least _________ from combustible material. - Answers :6 inches

Geschreven voor

Instelling
Lp installers
Vak
Lp installers

Documentinformatie

Geüpload op
22 maart 2025
Aantal pagina's
16
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Greaterheights Birkbeck, University of London
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1140
Lid sinds
3 jaar
Aantal volgers
882
Documenten
19493
Laatst verkocht
15 uur geleden

4,0

220 beoordelingen

5
120
4
43
3
24
2
11
1
22

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen