What NFPA Standard covers Sprinkler Systems? - ANSWERNFPA 13 What is the max travel distance to an exit in a sprinkler protected education building? - ANSWER200 ft What is Fire Resistance? - ANSWERThe ability of a structural assembly to maintain its load-bearing ability under fire conditions What is a beam? - ANSWERA horizontal structure member used between posts, columns, or walls. What is the activation temperature of an Orange Head Sprinkler? - ANSWER500-575 Degrees F (Classification is Ultra High) How often should extinguishers of 150lbs or less be hydrostatically tested? - ANSWER12 years (larger ones do not have to be tested) What is the name of a beam that supports other beams? - ANSWERGirder An inspector CANNOT be held liable for acts they consider necessary to fulfill their responsibilities but CAN be held liable for? - ANSWERThe manner in which they perform acts What are the three classes of Standpipe Systems? - ANSWERClass 1: Fire personnel only Class 2: Residential use (1 1/2" outlet) Class 3: Both (2.5" and 1.5") What is the name of the test used to rate flame spread? - ANSWERSteiner Tunnel Test

Meer zien Lees minder
Instelling
FLORIDA STATE FIRE INSPECTOR
Vak
FLORIDA STATE FIRE INSPECTOR









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
FLORIDA STATE FIRE INSPECTOR
Vak
FLORIDA STATE FIRE INSPECTOR

Documentinformatie

Geüpload op
3 maart 2025
Aantal pagina's
13
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

FLORIDA STATE FIRE INSPECTOR
2024 REVISED QUESTIONS AND
ANSWERS(GRADED A+)
What NFPA Standard covers Sprinkler Systems? - ANSWERNFPA 13

What is the max travel distance to an exit in a sprinkler protected education building?
- ANSWER200 ft

What is Fire Resistance? - ANSWERThe ability of a structural assembly to maintain
its load-bearing ability under fire conditions

What is a beam? - ANSWERA horizontal structure member used between posts,
columns, or walls.

What is the activation temperature of an Orange Head Sprinkler? - ANSWER500-
575 Degrees F (Classification is Ultra High)
How often should extinguishers of 150lbs or less be hydrostatically tested? -
ANSWER12 years (larger ones do not have to be tested)

What is the name of a beam that supports other beams? - ANSWERGirder

An inspector CANNOT be held liable for acts they consider necessary to fulfill their
responsibilities but CAN be held liable for? - ANSWERThe manner in which they
perform acts

What are the three classes of Standpipe Systems? - ANSWERClass 1: Fire
personnel only
Class 2: Residential use (1 1/2" outlet)
Class 3: Both (2.5" and 1.5")

What is the name of the test used to rate flame spread? - ANSWERSteiner Tunnel
Test

Who has the ultimate authority to make changes in fire codes? - ANSWERThe AHJ

What is the discharge size of the inspectors Test Connection? - ANSWERThe
discharge orifice shall be equal in size to the smallest sprinkler in the system

How often are pumps tested and run for standpipes? - ANSWERWeekly

What is the distance required between explosives and the unpacking area
(magazine)? - ANSWER50 feet

What type of sprinkler head hangs down? - ANSWERPendant

, How often are fire service elevators tested? - ANSWERMonthly

What is fire load? - ANSWERThe max amount of heat that can be produced if all the
combustible materials in a given area burn

Rate of Rise detectors depend on what? - ANSWERThe accelerator unbalances the
air pressure within the system

What type of material si Halon ineffective on? - ANSWERSelf-Oxidizing

What is the maximum travel distance for a Class D extinguisher - ANSWER75 feet
(Same as Class A)

What is the minimum clearance from combustible materials for cooking equipment? -
ANSWER18 Inches

What are the two common types of extinguishing agents in hood systems? -
ANSWERPotassium Carbonate, Potassium Acetate

What is the minimum distance between above ground flammable or combustible
storage tanks - ANSWER3 feet

What are the four basic components of a dry chemical extinguishing system? -
ANSWERStorage tank, Piping, Nozzle, Actuating Mechanism

What two materials is flame spread rating based on? - ANSWERAsbestos Cement
Board (0 rating) Red Oak Wood (100 rating)

Balconies and Mezzanines with a load greater than 100 must have how many means
of egress? - ANSWERNo less than two (same as floor)

What NFPA code covers Combustible and Flammable Liquids? - ANSWERNFPA 30

What is the minimum distance needed between LPG and other flammable liquid
storage tanks? - ANSWER20 feet

What are the three parts of Means of Egress - ANSWERExit access, Exit, Exit
discharge

What NFPA standard covers Standard for Professional Qualifications for Fire
Inspector? - ANSWERNFPA 1031

What is a Boiling Point (definition) - ANSWERTemperature at which the vapor
pressure of the liquid is equal to the external pressure applied to it.

What is chipboard - ANSWERWood chips glued together to make flat sheets

What type of valve limits flow in one direction? - ANSWERCheck Valves

Bricks laid lengthwise are called what course? - ANSWERStretcher Course

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
nursingismylife West Virginia University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
250
Lid sinds
2 jaar
Aantal volgers
174
Documenten
9126
Laatst verkocht
3 dagen geleden

3,6

38 beoordelingen

5
14
4
12
3
3
2
1
1
8

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen