100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Endocutters Part 1 Questions and Answers correct

Beoordeling
-
Verkocht
-
Pagina's
3
Cijfer
A+
Geüpload op
15-02-2025
Geschreven in
2024/2025

Endocutters Part 1 Questions and Answers correct Echelon Endopath stapler comes in these 3 different shaft lengths 280, 340, 440 mm Once the battery is inserted into the Echelon Flex Powered Stapler, it will begin draining and will mostly drained after 24 hours True What should a surgeon do if the vessel extends beyond the cut line markings of the Echelon PVS when the device is closed? Do not use the instrument under these circumstances One way compression can be achieved by the 3-point gap control knife construct that pulls the anvil and the channel into the correct gap to achieve appropriate staple height. Which of the following staplers have this mechanism in its design Echelon Endopath Stapler Echelon Flex GST comes in both 45 and 60 mm options True The GST systems powered platform allows ____ less movement at the end effector during firing on thick tissue as compared to manual staplers 88% Which features of the Echelon Flex PVS enable greater access and control than the competition (select all that apply) ALL OF THEM: 83% less distal tip movement 9mm shaft diameter 50 degree articulation Advanced placement tip 7mm Anvil Echelon Flex Endopath stapler cannot be articulated with the jaws closed True The ATS45 stapler comes packaged without a reload True The Echelon Flex GST system has ___ x less tissue slippage 4X The Echelon Flex Powered has ____ full control in the event of a power loss Manual override The following reload colors are available with the ATS45 Stapler White, Blue, Green The 3 main design changes in the GST system are Atraumatic pocket extensions, asymmetrical staple legs with bent tips, closed bottom cartridge channel How many rows of staples does the Echelon Flex PVS lay on each side of the cut line 2 rows The motor on the Echelon Powered stapler automatically adjusts speed when encountering more resistance True The Echelon Flex Endopath stapler can be fired a maximum of 12 times Which of the following features of the GST system provide stability and help control tissue movement (select all that apply) ALL OF THEM: pre-compression reloads with gripping ridge surface closed channel design powered firing The Echelon Endopath stapler, Echelon Flex Endopath stapler and Echelon Flex Powered Stapler are compatible with all existing Echelon cartridges. True Which of these factors can push staple legs proximally and laterally as they are ejected from the staple pockets, causing staple malformation Tisse Slippage Approximately how many pounds of lateral pressure is needed to articulate the Echelon Flex Endopath Stapler 1 What are the key benefits of the Echelon Flex GST System as it relates to reduced tissue slippage (Select all that apply) -Potentially reduce the number of reloads used in the procedure -Less sensitivity to the effects of various tissue thickness means reliable staple formation across a range of tissue thickness. Misalignment of the staple legs with _____ can also result from deflection of the ____ as a result of ____ placed on the stapling system Anvil pockets, cartridge channel, high loads What are the different techniques for articulating the Echelon Flex Endopath Stapler inside the body (select all that apply) Grasper body wall hand assisted The cartridge side of the end effector of the Echelon Flex Powered Plus stapler has a closed knife channel because It reduces the likelihood of bowing the cartridge deck laterally outwards and causing individual staples to miss anvil pockets during the firing sequence To ensure optimal staple formation, the anvil must be properly aligned with which of the following during firing Cartridge Channel

Meer zien Lees minder
Instelling
ECHELON
Vak
ECHELON








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
ECHELON
Vak
ECHELON

Documentinformatie

Geüpload op
15 februari 2025
Aantal pagina's
3
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Endocutters Part 1 Questions and
Answers correct

Echelon Endopath stapler comes in these 3 different shaft lengths - answer 280,
340, 440 mm

Once the battery is inserted into the Echelon Flex Powered Stapler, it will begin draining
and will mostly drained after 24 hours - answer True

What should a surgeon do if the vessel extends beyond the cut line markings of the
Echelon PVS when the device is closed? - answer Do not use the instrument under
these circumstances

One way compression can be achieved by the 3-point gap control knife construct that
pulls the anvil and the channel into the correct gap to achieve appropriate staple height.
Which of the following staplers have this mechanism in its design - answer Echelon
Endopath Stapler

Echelon Flex GST comes in both 45 and 60 mm options - answer True

The GST systems powered platform allows ____ less movement at the end effector
during firing on thick tissue as compared to manual staplers - answer 88%

Which features of the Echelon Flex PVS enable greater access and control than the
competition (select all that apply) - answer ALL OF THEM:
83% less distal tip movement
9mm shaft diameter
50 degree articulation
Advanced placement tip
7mm Anvil

Echelon Flex Endopath stapler cannot be articulated with the jaws closed - answer
True

The ATS45 stapler comes packaged without a reload - answer True

The Echelon Flex GST system has ___ x less tissue slippage - answer 4X

The Echelon Flex Powered has ____ full control in the event of a power loss - answer
Manual override
€11,40
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Pogba119 Harvard University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
48
Lid sinds
1 jaar
Aantal volgers
2
Documenten
4870
Laatst verkocht
1 maand geleden
NURSING TEST

BEST EDUCATIONAL RESOURCES FOR STUDENTS

3,9

9 beoordelingen

5
4
4
2
3
2
2
0
1
1

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen