GENERAL X-RAY MACHINE OPERATOR EXAM STUDY GUIDE
QUESTIONS WITH COMPLETE SOLUTIONS
Collimator definition -- Answer ✔✔ A box-like device attached under the tube housing
L. L. L. L. L. L. L. L. L. L. L. L.
that allows the limited operator to vary the size of the radiation field (a variable aperture)
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
Detent -- Answer ✔✔ A mechanism that tends to stop a moving part in a specific location
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
Computed radiography (CR) -- Answer ✔✔ Sometimes called "filmless systems" which
L. L. L. L. L. L. L. L. L. L.
produce images via a digital format using computer technology, eliminating the need for
L. L. L. L. L. L. L. L. L. L. L. L. L.
darkrooms
L.
Image receptor system (IR) -- Answer ✔✔ Consists of the X-ray film and the film holder,
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
also known as a cassette
L. L. L. L. L.
Central ray -- Answer ✔✔ A line in the center of the X-ray beam and perpendicular to
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
the long axis of the X-ray tube
L. L. L. L. L. L. L.
Attenuation -- Answer ✔✔ the absorption of x-ray beam by matter L. L. L. L. L. L. L. L. L. L.
Control booth -- Answer ✔✔ The portion of the X-ray room that is protected from
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
scatter radiation and safe during exposures
L. L. L. L. L. L.
Grid or bucky -- Answer ✔✔ A device to protect the film from being fogged by scatter
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
radiation
L.
Remnant (exit) radiation -- Answer ✔✔ the resulting beam that exits from the patient and
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
creates image
L. L.
Tube port -- Answer ✔✔ An opening in the X-ray tube where X-rays that are traveling in
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
a useful direction exit
L. L. L. L.
,Scatter radiation -- Answer ✔✔ photons that interact with the body's matter and travel in
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
a different direction
L. L. L.
Primary radiation -- Answer ✔✔ The X-ray beam that leaves the tube and is
L. L. L. L. L. L. L. L. L. L. L. L. L.
unattenuated, except by air
L. L. L. L.
Longitudinal -- Answer ✔✔ Tube motion along the long axis of the table L. L. L. L. L. L. L. L. L. L. L. L.
Transverse -- Answer ✔✔ Tube motion across the table, at right angles to longitudinal
L. L. L. L. L. L. L. L. L. L. L. L. L.
Vertical -- Answer ✔✔ Tube motion up and down, increasing or decreasing the distance
L. L. L. L. L. L. L. L. L. L. L. L. L.
between the tube and the table
L. L. L. L. L. L.
Angle (tilt, roll) -- Answer ✔✔ Permits angulation of the tube along the longitudinal axis of
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
the table
L. L.
Rotation -- Answer ✔✔ Allows the entire tube stand to turn on its axis
L. L. L. L. L. L. L. L. L. L. L. L. L.
X-Ray tube -- Answer ✔✔ the source of x-rays
L. L. L. L. L. L. L. L.
Phosphor material -- Answer ✔✔ Used in a closed cassette rather than on film to obtain
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
computed radiography (CR) images
L. L. L. L.
Ceiling support system -- Answer ✔✔ most common, has 2 sets of rails that allow for
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
lateral and longitudinal movement, lock and raise and lower to obtain the correct
L. L. L. L. L. L. L. L. L. L. L. L. L.
distances
L.
Floor to ceiling support system -- Answer ✔✔ Has a single column with rollers at each
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
end, one attached to the ceiling-mounted rail and the other attached to a floor-mounted
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
rail
L.
What are the three parts of the external part of the x-ray tube? -- Answer ✔✔ support
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
structure, protective housing, and glass or metal enclosure
L. L. L. L. L. L. L. L.
, What are the internal parts of the x-ray tube? -- Answer ✔✔ cathode and anode
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
Cathode -- Answer ✔✔ a negatively charged electrode that is the source of electrons in
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
an electrical device
L. L. L.
Anode -- Answer ✔✔ a positively charged electrode by which electrons leave an
L. L. L. L. L. L. L. L. L. L. L. L.
electrical device. It conducts electricity and radiates heat and contains the target.
L. L. L. L. L. L. L. L. L. L. L. L.
Thermionic emission -- Answer ✔✔ is the giving off of electrons from the surface of a hot
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
metal
L.
(tungsten filament) L.
Glass or metal enclosure -- Answer ✔✔ Encloses the entire cathode and anode assembly
L. L. L. L. L. L. L. L. L. L. L. L. L.
except the stator
L. L. L.
Focusing cup -- Answer ✔✔ a recessed area where the filament lies, directing the
L. L. L. L. L. L. L. L. L. L. L. L. L.
electrons toward the anode
L. L. L. L.
What are the primary parts of the cathode? -- Answer ✔✔ filament and focusing cup
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
Filament -- Answer ✔✔ a very tightly wound wire, when heated up it allows electrons to
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
become free
L. L.
Anode target -- Answer ✔✔ area of the anode struck by the electrons from the cathode
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
Protective housing -- Answer ✔✔ a protective barrier against leakage and scatter
L. L. L. L. L. L. L. L. L. L. L.
radiation. It additionally isolates high voltages and aids in tube cooling.
L. L. L. L. L. L. L. L. L. L. L.
Tube window -- Answer ✔✔ where the primary beam exits the tube
L. L. L. L. L. L. L. L. L. L. L.
Stationary anode -- Answer ✔✔ a nonmoving anode, usually found in dental & small
L. L. L. L. L. L. L. L. L. L. L. L. L.
portable radiography units
L. L. L.
Rotating anode -- Answer ✔✔ an anode that turns on an axis to increase x-ray
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
production while dissipating heat
L. L. L. L.
QUESTIONS WITH COMPLETE SOLUTIONS
Collimator definition -- Answer ✔✔ A box-like device attached under the tube housing
L. L. L. L. L. L. L. L. L. L. L. L.
that allows the limited operator to vary the size of the radiation field (a variable aperture)
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
Detent -- Answer ✔✔ A mechanism that tends to stop a moving part in a specific location
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
Computed radiography (CR) -- Answer ✔✔ Sometimes called "filmless systems" which
L. L. L. L. L. L. L. L. L. L.
produce images via a digital format using computer technology, eliminating the need for
L. L. L. L. L. L. L. L. L. L. L. L. L.
darkrooms
L.
Image receptor system (IR) -- Answer ✔✔ Consists of the X-ray film and the film holder,
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
also known as a cassette
L. L. L. L. L.
Central ray -- Answer ✔✔ A line in the center of the X-ray beam and perpendicular to
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
the long axis of the X-ray tube
L. L. L. L. L. L. L.
Attenuation -- Answer ✔✔ the absorption of x-ray beam by matter L. L. L. L. L. L. L. L. L. L.
Control booth -- Answer ✔✔ The portion of the X-ray room that is protected from
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
scatter radiation and safe during exposures
L. L. L. L. L. L.
Grid or bucky -- Answer ✔✔ A device to protect the film from being fogged by scatter
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
radiation
L.
Remnant (exit) radiation -- Answer ✔✔ the resulting beam that exits from the patient and
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
creates image
L. L.
Tube port -- Answer ✔✔ An opening in the X-ray tube where X-rays that are traveling in
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
a useful direction exit
L. L. L. L.
,Scatter radiation -- Answer ✔✔ photons that interact with the body's matter and travel in
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
a different direction
L. L. L.
Primary radiation -- Answer ✔✔ The X-ray beam that leaves the tube and is
L. L. L. L. L. L. L. L. L. L. L. L. L.
unattenuated, except by air
L. L. L. L.
Longitudinal -- Answer ✔✔ Tube motion along the long axis of the table L. L. L. L. L. L. L. L. L. L. L. L.
Transverse -- Answer ✔✔ Tube motion across the table, at right angles to longitudinal
L. L. L. L. L. L. L. L. L. L. L. L. L.
Vertical -- Answer ✔✔ Tube motion up and down, increasing or decreasing the distance
L. L. L. L. L. L. L. L. L. L. L. L. L.
between the tube and the table
L. L. L. L. L. L.
Angle (tilt, roll) -- Answer ✔✔ Permits angulation of the tube along the longitudinal axis of
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
the table
L. L.
Rotation -- Answer ✔✔ Allows the entire tube stand to turn on its axis
L. L. L. L. L. L. L. L. L. L. L. L. L.
X-Ray tube -- Answer ✔✔ the source of x-rays
L. L. L. L. L. L. L. L.
Phosphor material -- Answer ✔✔ Used in a closed cassette rather than on film to obtain
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
computed radiography (CR) images
L. L. L. L.
Ceiling support system -- Answer ✔✔ most common, has 2 sets of rails that allow for
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
lateral and longitudinal movement, lock and raise and lower to obtain the correct
L. L. L. L. L. L. L. L. L. L. L. L. L.
distances
L.
Floor to ceiling support system -- Answer ✔✔ Has a single column with rollers at each
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
end, one attached to the ceiling-mounted rail and the other attached to a floor-mounted
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
rail
L.
What are the three parts of the external part of the x-ray tube? -- Answer ✔✔ support
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
structure, protective housing, and glass or metal enclosure
L. L. L. L. L. L. L. L.
, What are the internal parts of the x-ray tube? -- Answer ✔✔ cathode and anode
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
Cathode -- Answer ✔✔ a negatively charged electrode that is the source of electrons in
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
an electrical device
L. L. L.
Anode -- Answer ✔✔ a positively charged electrode by which electrons leave an
L. L. L. L. L. L. L. L. L. L. L. L.
electrical device. It conducts electricity and radiates heat and contains the target.
L. L. L. L. L. L. L. L. L. L. L. L.
Thermionic emission -- Answer ✔✔ is the giving off of electrons from the surface of a hot
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
metal
L.
(tungsten filament) L.
Glass or metal enclosure -- Answer ✔✔ Encloses the entire cathode and anode assembly
L. L. L. L. L. L. L. L. L. L. L. L. L.
except the stator
L. L. L.
Focusing cup -- Answer ✔✔ a recessed area where the filament lies, directing the
L. L. L. L. L. L. L. L. L. L. L. L. L.
electrons toward the anode
L. L. L. L.
What are the primary parts of the cathode? -- Answer ✔✔ filament and focusing cup
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
Filament -- Answer ✔✔ a very tightly wound wire, when heated up it allows electrons to
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
become free
L. L.
Anode target -- Answer ✔✔ area of the anode struck by the electrons from the cathode
L. L. L. L. L. L. L. L. L. L. L. L. L. L. L.
Protective housing -- Answer ✔✔ a protective barrier against leakage and scatter
L. L. L. L. L. L. L. L. L. L. L.
radiation. It additionally isolates high voltages and aids in tube cooling.
L. L. L. L. L. L. L. L. L. L. L.
Tube window -- Answer ✔✔ where the primary beam exits the tube
L. L. L. L. L. L. L. L. L. L. L.
Stationary anode -- Answer ✔✔ a nonmoving anode, usually found in dental & small
L. L. L. L. L. L. L. L. L. L. L. L. L.
portable radiography units
L. L. L.
Rotating anode -- Answer ✔✔ an anode that turns on an axis to increase x-ray
L. L. L. L. L. L. L. L. L. L. L. L. L. L.
production while dissipating heat
L. L. L. L.