FLS Modules UPDATED Exam Questions and CORRECT Answers Laproscopic instruments diameter and length ranges - CORRECT ANSWER - 2-10mm, 30-45cm hopkins rod lens - CORRECT ANSWER - light has to travel back through the rod to capture the image. decreasing light in the camera for... - CORRECT ANSWER - decreasing diameter, increasing scope angle (ie 5mm and 30 degree has less light than 10mm 0 degree

Meer zien Lees minder
Instelling
FLS
Vak
FLS










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
FLS
Vak
FLS

Documentinformatie

Geüpload op
26 januari 2025
Aantal pagina's
19
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

FLS Modules UPDATED Exam Questions
and CORRECT Answers
Laproscopic instruments diameter and length ranges - CORRECT ANSWER - 2-10mm,
30-45cm


hopkins rod lens - CORRECT ANSWER - light has to travel back through the rod to
capture the image.


decreasing light in the camera for... - CORRECT ANSWER - decreasing diameter,
increasing scope angle (ie 5mm and 30 degree has less light than 10mm 0 degree)


When is zero degree scope most useful - CORRECT ANSWER - when working in a small
area directly in line with the scope and ports, like the pelvis


how to check fiber optics light connection - CORRECT ANSWER - black dots= broken
fibers


why does it fog up? - CORRECT ANSWER - temperature and humidity discrepancy
between the OR and body


tools for defogging - CORRECT ANSWER - FRED antifog (must dry before putting back
in), put laparoscope in hot water


methods to clean a smudged lens - CORRECT ANSWER - gently wipe on clean tissue
(liver, uterus, bowel), remove scope and clean with hot water and gauze


Insufflation gas type and reasoning - CORRECT ANSWER - CO2- readily available,
inexpensive, non combustable, warmed and humidified better

,high flow insufflation - CORRECT ANSWER - 10 or more L per minute



preventing loss of pneumo with suctioning - CORRECT ANSWER - keep suction tip
below the fluid level


most common light source - CORRECT ANSWER - 300W xenon lamp



Troubleshooting steps: gas preOP - CORRECT ANSWER - 1. check that co2 tank is full
2. check co2 tank gasket is secured
3. check that spare co2 tank is available in the OR


troubleshooting steps: image - CORRECT ANSWER - 1. check that the monitor is
plugged in and turned on 2. check that all cables are connected securely


troubleshooting steps: loss of working space: insufflator settings: measured pressure is the same
or higher than the preset pressure - CORRECT ANSWER - 1. the patient may not be
adequately relaxed or there is a mechanical block of gas flow
2. inspect abdomen for rhythmic muscle contraction and palpate the abdomen for firmness
3. check port valves to make sure they are open
4. check for kinks in tubing and make sure no one is standing on them


troubleshooting steps: loss of working space: insufflator settings: low pressure and high flow rate
- CORRECT ANSWER - 1. there is a leak in the insufflation circuit
2. check that the tubing has not become disconnected from insufflator or port
3. check that all valves are closed
4. check all port sites for leaking co2
5. check for foley catheter bag distention or bowel distention

, troubleshooting steps: loss of working space: insufflator settings: low pressure and no flow -
CORRECT ANSWER - 1. make sure that the insufflator power is on
2. check gas level in the tank


troubleshooting steps: loss of working space: complete loss of operative image - CORRECT
ANSWER - 1. check for disconnected power cords, video cables
2. check for blown light source bulb
3. check for disconnected light cable


Monopolar electrosurgery curcuit - CORRECT ANSWER - electrical surgical unit--
>active electrode-->patient tissue-->dispersive electrode (grounding pad)


low frequency from wall source to high frequency at active electrode


monopolar: tissue coagulation - CORRECT ANSWER - occurs as a result of tissue heating
and protein denaturation.


monopolar: desiccation - CORRECT ANSWER - tissue temp rises--->water is evaporated
from the tissue--> increased impedance---> electricity stops flowing because of increased
resistance-->tissue turns brown, bubbles and steams.


Hemostasis due to fibrous binding between dehydrated, denatured cells of vessel endothelium


monopolar: current density - CORRECT ANSWER - amount of current flowing through
cross sectional area.


directly proportional to power, inversely related to tissue resistance


ie larger the area, less current density
€9,18
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
MGRADES Stanford University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1074
Lid sinds
1 jaar
Aantal volgers
102
Documenten
68976
Laatst verkocht
1 dag geleden
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3,8

170 beoordelingen

5
73
4
30
3
45
2
8
1
14

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen