100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Surgical Technology Certification Exam Questions & Verified Answers | 100% Pass Rate Guaranteed | Latest Updated Version

Beoordeling
-
Verkocht
-
Pagina's
48
Cijfer
A+
Geüpload op
02-12-2024
Geschreven in
2024/2025

The surgeon asks that multiple suture and hernia mesh that were not on the preference card be opened during the repair of a large umbilical hernia. The surgical technologist should recognize that: a. items on the preference card are only to be changed by the surgeon or the unit clerk b. sterile supply associates who stock the hernia mesh are responsible for adding hernia mesh to the preference card c. preference card changes are unnecessary; both hernia mesh and suture are case dependent. d. suture may be case dependent, but the hernia mesh is integral to the procedure and should be added to the preference card Ans Answer: D Which of the following precautions should be taken by the surgical team when working with polymethyl methacrylate as a bone cement? a. wear latex free gloves, as polymethyl methacrylate interacts negatively with latex b. remove contact lenses as polymethyl methacrylate can melt contact lenses and cause corneal burns c. make sure the patient does not have a latex allergy because polymethyl methacrylate and latex have the same chemical properties d. Limit the # of sponges on the field as polymethyl methacrylate can negatively interact with the cotton fibers in the sponges. Ans Answer: B Which of the following daily tests must be performed on the pre-vacuum sterilizer before using it? a. Gravity b. Biological indicator c. Bowie-Dick d. Chemical indicator Ans Page 2 of 48 | © copyright 2024/2025 | Grade A+ Master01 | Dec, 2024/2025 | Latest update Answer: C What is the minimum exposure time in a flash sterilizer for unwrapped instruments? a. 1 minute b. 3 minutes c. 5 minutes d. 7 minutes Ans Answer: B [pre-vac] no lumen - 3 minutes ; lumen - 4 minutes Which of the following is the correct temperature for the flash sterilizer operation? a. 132*C (270*F) b. 126*C (260*F) c. 135*C (275*F) d. 129*C (265*F) Ans Answer: A Which of the following is the proper temperature and time that the chamber of a steam sterilizer must reach in order to ensure that all spores have been eliminated? a. 270*F for 4 minutes b. 350*F for 4 minutes c. 240*F for 10 minutes d. 350*F for 10 mintues Ans Answer: A [pre-vac] temp: 270*F ; time: 3-4 minutes ; pressure: 27 psi The Sterrad sterilization system most commonly uses which of the following chemical solutions? a. hydrogen peroxide b. gluteraldehyde c. alcohol d. peracetic acid Ans Answer: A [Sterrad] make sure its plugged in - needs electricity Page 3 of 48 | © copyright 2024/2025 | Grade A+ Master01 | Dec, 2024/2025 | Latest update Which of the following is used to achieve high level disinfection with a minimum exposure time of 20-45 minutes? a. chlorine bleach compounds b. gluteraldehyde c. hydrogen peroxide d. iodine and iodophors Ans Answer: B During decontamination of a flexible endoscope, which of the following tests should be given to inspect the proper function of the endoscope and to ensure that it can be properly sterilized? a. leak test b. electrical component test c. bacteria swab test d. fiber optic light test Ans Answer: A Which of the fol

Meer zien Lees minder
Instelling
Surgical Technology Certification
Vak
Surgical Technology Certification











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Surgical Technology Certification
Vak
Surgical Technology Certification

Documentinformatie

Geüpload op
2 december 2024
Aantal pagina's
48
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Page 1 of 48 | © copyright 2024/2025 | Grade A+




Surgical Technology Certification Exam
Questions & Verified Answers 2024-2025 |
100% Pass Rate Guaranteed | Latest Updated
Version

The surgeon asks that multiple suture and hernia mesh that were not on the
preference card be opened during the repair of a large umbilical hernia. The
surgical technologist should recognize that:
a. items on the preference card are only to be changed by the surgeon or the
unit clerk
b. sterile supply associates who stock the hernia mesh are responsible for
adding hernia mesh to the preference card
c. preference card changes are unnecessary; both hernia mesh and suture are
case dependent.
d. suture may be case dependent, but the hernia mesh is integral to the
procedure and should be added to the preference card
Ans

Answer: D

Which of the following precautions should be taken by the surgical team when
working with polymethyl methacrylate as a bone cement?
a. wear latex free gloves, as polymethyl methacrylate interacts negatively with
latex
b. remove contact lenses as polymethyl methacrylate can melt contact lenses
and cause corneal burns
c. make sure the patient does not have a latex allergy because polymethyl
methacrylate and latex have the same chemical properties
d. Limit the # of sponges on the field as polymethyl methacrylate can
negatively interact with the cotton fibers in the sponges.
Ans

Answer: B

Which of the following daily tests must be performed on the pre-vacuum
sterilizer before using it?
a. Gravity
b. Biological indicator
c. Bowie-Dick
d. Chemical indicator
Ans


Master01 | Dec, 2024/2025 | Latest update

,Page 2 of 48 | © copyright 2024/2025 | Grade A+

Answer: C

What is the minimum exposure time in a flash sterilizer for unwrapped
instruments?
a. 1 minute
b. 3 minutes
c. 5 minutes
d. 7 minutes
Ans

Answer: B

[pre-vac] no lumen - 3 minutes ; lumen - 4 minutes

Which of the following is the correct temperature for the flash sterilizer
operation?
a. 132*C (270*F)
b. 126*C (260*F)
c. 135*C (275*F)
d. 129*C (265*F)
Ans

Answer: A

Which of the following is the proper temperature and time that the chamber of
a steam sterilizer must reach in order to ensure that all spores have been
eliminated?
a. 270*F for 4 minutes
b. 350*F for 4 minutes
c. 240*F for 10 minutes
d. 350*F for 10 mintues
Ans

Answer: A

[pre-vac] temp: 270*F ; time: 3-4 minutes ; pressure: 27 psi

The Sterrad sterilization system most commonly uses which of the following
chemical solutions?
a. hydrogen peroxide
b. gluteraldehyde
c. alcohol
d. peracetic acid
Ans

Answer: A

[Sterrad] make sure its plugged in - needs electricity



Master01 | Dec, 2024/2025 | Latest update

,Page 3 of 48 | © copyright 2024/2025 | Grade A+


Which of the following is used to achieve high level disinfection with a
minimum exposure time of 20-45 minutes?
a. chlorine bleach compounds
b. gluteraldehyde
c. hydrogen peroxide
d. iodine and iodophors
Ans

Answer: B

During decontamination of a flexible endoscope, which of the following tests
should be given to inspect the proper function of the endoscope and to ensure
that it can be properly sterilized?
a. leak test
b. electrical component test
c. bacteria swab test
d. fiber optic light test
Ans

Answer: A

Which of the following is the fastest method of sterilization?
a. gas
b. steam
c. steris
d. dry heat
Ans

Answer: B

Which of the following is the correct temperature for pre-vacuum sterilization?
a. 212*F
b. 170*F
c. 300*F
d. 270*F
Ans

Answer: D

Which of the following tests is specifically meant to test and monitor the
efficiency of the high - vacuum steam sterilizer?
a. biological indicator test
b. DART test
c. chemical indicator test
d. EtO test
Ans




Master01 | Dec, 2024/2025 | Latest update

, Page 4 of 48 | © copyright 2024/2025 | Grade A+

Answer: B

DART test = Bowie Dick test

The surgical team must verify each package is properly labeled with
a. date of processing and method of sterilization
b. date of processing and indicator
c. method of sterilization and expiration date
d. indicator and expiration date
Ans

Answer: B

How many times a day should a DART test be preformed?
a. with every load
b. every shift change
c. once every 24 hours
d. weekly
Ans

Answer: C

How often must a biological control test be run?
a. every day
b. every cycle
c. once a week
d. once a month
Ans

Answer: A

[pg. 163]

The Bowie-Dick test for pre-vacuum sterilizers checks for which of the
following conditions?
a. that the appropriate steam level was reached
b. air leaks in the sterilizer chamber
c. broken sterilizer jacket
d. that the sterilizer is ready to process instruments
Ans

Answer: B

lot control numbers should be placed on each package sterilized and on the...
a. sterilizer maintenance record
b. sterilization load record
c. nursing documentation
d. cover of the patient's chart
Ans

Master01 | Dec, 2024/2025 | Latest update

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Graders Chamberlian School of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
499
Lid sinds
2 jaar
Aantal volgers
167
Documenten
26051
Laatst verkocht
1 dag geleden
Study Smart

Your one-stop resource for high-quality, exam-focused study materials. Here, you'll find expertly crafted summaries, past exam papers, notes, and assignments tailored to help you succeed in your courses. Every document is written with clarity, accuracy, and exam performance in mind—saving you hours of studying and helping you boost your grades. ✅ Clear and well-structured content ✅ Covers key exam topics and common questions ✅ Trusted by students for academic success ✅ Instant downloads and affordable prices Whether you're cramming for finals or just staying ahead in class, my materials are designed to make your studying smarter, not harder. Take a look around and get the edge you need!

Lees meer Lees minder
3,8

120 beoordelingen

5
53
4
26
3
21
2
4
1
16

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen