100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

ARRT MRI REGISTRY EXAM Complete Questions and Correct Answers (2024/2025) FINAL EXAM Already Graded

Beoordeling
-
Verkocht
-
Pagina's
31
Cijfer
A+
Geüpload op
17-11-2024
Geschreven in
2024/2025

ARRT MRI REGISTRY EXAM Complete Questions and Correct Answers (2024/2025) FINAL EXAM Already Graded Which of the following parameter adjustments will LENGTHEN scan time in an MR pulse sequence? I. Decrease TR II. Increase TR III. Increase ETL IV. Decrease ETL V. Decrease NEX VI. Increase NEX VII. Enable Half-fourier VIII. Increase parallel imaging factor IX. Decrease parallel imaging factor X. Enable anti-aliasing - ANSWER II, IV, VI and IX Which of the following parameter adjustments help to improve SNR in an MR image? I. Increase TR II.Reduce Phase Matrix III. Reduce Pixel Size IV. Increase FOV V. Reduce rBW VI. Increase rBW VII. Increase NSA VIII. Decrease NSA IX. Increase ETL X. Decrease ETL - ANSWER I, II, IV, V, VII and X In a fast spin echo sequence with a 25 cm FOV, 224 x 320 matrix, TR 2500, 100 TE, 3mm slice thickness, 12 ETL and 4 NEX, the scan time would be: A. 2 minutes 6 seconds B. 3 minutes 7 seconds C. 3 minutes 11 seconds D. 4 minutes 27 seconds E. 4 minutes 44 seconds - ANSWER 3 minutes 7 seconds The phase encoding step is performed: A. During frequency encoding B. In place of frequency encoding C. Prior to frequency encoding D. Following frequency encoding - ANSWER Prior to frequency encoding Permanent magnets with a vertical magnetic field use surface coils that are: A. Phased array B. Linear C. Quadrature D. Solenoids - ANSWER Solenoids Gradient echo sequences can yield either T1 or T2* characteristics, with influences caused by all of the following EXCEPT: A. Chemical shift B. Inhomogeneity C. Susceptibility D. Inversion time - ANSWER Inversion time In what orientation would a tear of the collateral ligaments of the knee be best visualized? A. Sagittal B. Axial C. Transverse D. Coronal E. None of the above - ANSWER Coronal RF energy used in MRI is classified as: A. Low energy, nonionizing radiation B. Low energy, ionizing radiation C. High energy, nonionizing radiation D. High energy, ionizing radiation - ANSWER Low energy, nonionizing radiation On T1 weighted images of the spine, the CSF (cerebrospinal fluid) appears: A. Isointense to the spinal cord B. Hypointense to the spinal cord C. Hyperintense to the spinal cord D. None of the above - ANSWER Hypointense to the spinal cord Single order gradient moment nulling does not compensate for: A. Constant velocity flow B. Accelerated flow C. Reverse flow D. B and C - ANSWER B and C The gradient rise time is defined as the: A. Time it takes longitudinal magnetization to regrow B. Time between TI and initial RF pulse C. Speed rate of ascent or descent of a gradient from zero to its maximum amplitude D. Time it takes for the gradient to reach its full amplitude - ANSWER Time it takes for the gradient to reach its full amplitude In an MRA sequence, the removal of signal from vessels is accomplished by: A. Spectral presaturation B. Spatial presaturation C. Gradient moment nulling D. B and C E. None of the above - ANSWER Spatial prostration CSF suppression is performed with which type of technique? A. FLAIR B. STIR C. SPGR D. FISP - ANSWER FLAIR Magnetic field inhomogeneity is expressed in: A. Watts per kilogram B. Gauss per centimeter C. Parts per million D. Tesla per meter - ANSWER Parts per million

Meer zien Lees minder
Instelling
ARRT MRI REGISTRY
Vak
ARRT MRI REGISTRY











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
ARRT MRI REGISTRY
Vak
ARRT MRI REGISTRY

Documentinformatie

Geüpload op
17 november 2024
Aantal pagina's
31
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

ARRT MRI REGISTRY EXAM
Complete Questions and Correct Answers
(2024/2025) FINAL EXAM
Already Graded
Which of the following parameter adjustments will LENGTHEN scan time in an
MR pulse sequence?
I. Decrease TR
II. Increase TR
III. Increase ETL
IV. Decrease ETL
V. Decrease NEX
VI. Increase NEX
VII. Enable Half-fourier
VIII. Increase parallel imaging factor
IX. Decrease parallel imaging factor
X. Enable anti-aliasing - ANSWER ✔ II, IV, VI and IX

Which of the following parameter adjustments help to improve SNR in an MR
image?
I. Increase TR
II.Reduce Phase Matrix
III. Reduce Pixel Size
IV. Increase FOV
V. Reduce rBW
VI. Increase rBW
VII. Increase NSA
VIII. Decrease NSA
IX. Increase ETL
X. Decrease ETL - ANSWER ✔ I, II, IV, V, VII and X

In a fast spin echo sequence with a 25 cm FOV, 224 x 320 matrix, TR 2500, 100
TE, 3mm slice thickness, 12 ETL and 4 NEX, the scan time would be:
A. 2 minutes 6 seconds
B. 3 minutes 7 seconds
C. 3 minutes 11 seconds
D. 4 minutes 27 seconds

,E. 4 minutes 44 seconds - ANSWER ✔ 3 minutes 7 seconds

The phase encoding step is performed:
A. During frequency encoding
B. In place of frequency encoding
C. Prior to frequency encoding
D. Following frequency encoding - ANSWER ✔ Prior to frequency encoding

Permanent magnets with a vertical magnetic field use surface coils that are:
A. Phased array
B. Linear
C. Quadrature
D. Solenoids - ANSWER ✔ Solenoids

Gradient echo sequences can yield either T1 or T2* characteristics, with
influences caused by all of the following EXCEPT:
A. Chemical shift
B. Inhomogeneity
C. Susceptibility
D. Inversion time - ANSWER ✔ Inversion time

In what orientation would a tear of the collateral ligaments of the knee be best
visualized?
A. Sagittal
B. Axial
C. Transverse
D. Coronal
E. None of the above - ANSWER ✔ Coronal

RF energy used in MRI is classified as:
A. Low energy, nonionizing radiation
B. Low energy, ionizing radiation
C. High energy, nonionizing radiation
D. High energy, ionizing radiation - ANSWER ✔ Low energy, nonionizing
radiation

On T1 weighted images of the spine, the CSF (cerebrospinal fluid) appears:
A. Isointense to the spinal cord
B. Hypointense to the spinal cord

,C. Hyperintense to the spinal cord
D. None of the above - ANSWER ✔ Hypointense to the spinal cord

Single order gradient moment nulling does not compensate for:
A. Constant velocity flow
B. Accelerated flow
C. Reverse flow
D. B and C - ANSWER ✔ B and C

The gradient rise time is defined as the:
A. Time it takes longitudinal magnetization to regrow
B. Time between TI and initial RF pulse
C. Speed rate of ascent or descent of a gradient from zero to its maximum
amplitude
D. Time it takes for the gradient to reach its full amplitude - ANSWER ✔ Time it
takes for the gradient to reach its full amplitude

In an MRA sequence, the removal of signal from vessels is accomplished by:
A. Spectral presaturation
B. Spatial presaturation
C. Gradient moment nulling
D. B and C
E. None of the above - ANSWER ✔ Spatial presaturation

CSF suppression is performed with which type of technique?
A. FLAIR
B. STIR
C. SPGR
D. FISP - ANSWER ✔ FLAIR

Magnetic field inhomogeneity is expressed in:
A. Watts per kilogram
B. Gauss per centimeter
C. Parts per million
D. Tesla per meter - ANSWER ✔ Parts per million

During dynamic enhanced imaging for vasculature or visceral structures, contrast
is administered and k-space is filled with __________ to ensure that the contrast
enhancement is well visualized.

, A. Centric
B. Linear
C. Reverse centric
D. Reverse linear - ANSWER ✔ Centric

To produce a high quality reformatted image, the:
A. Acquisition voxel should be anisotropic
B. Acquisition voxel should be isotropic
C. NEX >4 should be utilized
D. Acquisition voxel should be rectangular - ANSWER ✔ Acquisition voxel
should be isotropic

When imaging a hemorrhagic infarct in the brain, which pulse sequence would
demonstrate the magnetic susceptibility effects better?
A. Spin echo
B. Fast spin echo
C. Inversion recovery
D. Gradient echo
E. Multi echo spin echo
F. FLAIR - ANSWER ✔ Gradient echo

Due to the lack of 180° RF refocusing pulse, the gradient echo sequence is more
susceptible to magnetic field inhomogeneities, such as hemosiderin from blood
products. The hemosiderin is highly magnetic because it is principally iron.

Which of the following sequences is the most insensitive to magnetic field
inhomogeneity?
A. RF spoiled gradient echo
B. Spin echo
C. Steady state rephased gradient echo
D. Echo planar - ANSWER ✔ Spin echo

The MRI system component that provides the ability to perform spatial encoding
is the:
A. Shim system
B. Main magnet
C. Gradient system
D. Radiofrequency system - ANSWER ✔ Gradient system

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
SmartscoreAaron Chicago State University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
36
Lid sinds
1 jaar
Aantal volgers
3
Documenten
3090
Laatst verkocht
2 weken geleden
SMARTSCORES LIBRARY

Get top-tier academic support for Psychology, Nursing, Business, Engineering, HRM, Math, and more. Our team of professional tutors delivers high-quality homework, quiz, and exam assistance—ensuring scholarly excellence and grade-boosting results. Trust our collaborative expertise to help you succeed in any course at U.S.A Institutions.

3,8

4 beoordelingen

5
2
4
1
3
0
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen