Technicians maintaining, servicing, repairing, or disposing of low-pressure appliances must be certified as: - Type III or Universal Technician The owner &/or operator of the equipment is responsible for keeping: - records including: leak inspections & any completed leak repair verification tests It's the _______ &/or ___________ responsibility to obtain service records from the servicing company doing any work on an appliancem - owner &/ or operator As of 11/14/94, the sale of _______ & _________ refrigerants is restricted to certified technicians - CFC & HCFC As of 1/1/18, the sale of _______ & ________ are also restricted to certified technicians - hfcs & hfos Low-pressure systems are semi-hermetic & operate below: - atmospheric pressure (in a vacuum) Leaks in the gaskets or fittings will cause ___ & _________ to enter the system - air & moisture Leaks must be repaired to reduce the operation of the ________ unit & ______ of refrigerant - purge / loss Leak checking a charged, _____-__________ refrigeration unit is to pressurize the system using controlled hot water or heater blankets - low-pressure When controlled hot water or heater blankets are not feasible on leak checking a charged, low-pressure unit, use __________ to increase system pressure - nitrogen When pressurizing a system, don't exceed _____ psig - 10 Exceeding ____ psig can cause the rupture disk to fail - 10 When leak testing a _______ _____, be certain the water has been removed before placing the leak detector probe through the: - water box / drain valve To leak test a tube, use a ____________ tube test kit - hydrostatic Systems with open drive compressors are prone to leaks at the: - shaft seal Controlled hot water or heating blankets can be used to raise the pressure in a ______-_________ for the purpose of opening the system for a: - low-pressure / non-major repair What does a "major repair" under EPA regulations: - any maintenance, service, or repair involving the removal of the following: compressor, condenser, evaporator, or any auxiliary heat exchanger coil Starting in 2019, EPA regulations require that systems containing more than _____ lbs of refrigerant be repaired when the annual leak rate exceeds a ___________ of the refrigerant charge - 50 / percentage The appliance must be checked after each ________ to verify the leak was successfully repaired - repair Comfort cooling & other types of appliances (ex: humidifiers): - 10% Commerical refrigeration: - 20% Industrial process refrigeration: - 30% When the leak rate exceeds the ______________ percentage on a low-pressure system, the system owner must repair the appliance enough to bring the leak rate below the: - maximum / threshold, or retrofit or retire the appliance An appliance may be ______________ if it's ______ _______ & the leaking section or component is isolated & ___________ of refrigerant to the ______ required level - mothballed / shut down / evacuated / EPA's Refrigerant charge of ______ lbs or greater has exceeded the threshold leak rate, it'll be _____________ or _____________ using a refrigerant exempt from the venting prohibition, owners or operators have _____ months to replace/retrofit the appliance - 50 / retrofitted or replaced / 18 LOW-PRESSURE APPLIANCE LEAKING ABOVE THE LEAK RATE THRESHOLD MUST BE REPAIRED so that it leaks below the threshold & the INITIAL VERIFICATION TEST CONDUCT WITHIN _____ DAYS UNLESS GRANTED ADDITIONAL TIME - 30 INITIAL LEAK-TEST VERIFICATION must be performed WITHIN _____ days (or _______ days if an industrial process shutdown is required) of an appliance exceeding the appliance leak rate. - 30 / 120 The FOLLOW-UP LEAK-TEST MUST BE PERFORMED WITHIN ____ days of the initial leak-test - 10 Each time a system is topped off or recharged the leak-rate must be: - recalculated The deadline to replace or retrofit an appliance ______ __ ________ when a certified service TECHNICIAN IS NOT AVAILABLE to do the work - CANNOT BE EXTENDED ALL RECORDS FOR LEAK INSPECTIONS, INITIAL VERIFICATION, VERIFICATION TESTS, & RECORDS OF RECOVERED REFRIGERANT FROM EQUIPMENT WITH ___ to ____ lbs OF REFRIGERANT MUST BE KEPT FOR ___ YEARS JUST AS IN TYPE II APPLIANCES - 5 to 50 / 3 A recovery unit's high-pressure CUT-OUT IS SET FOR ____ PSIG when evacuating the refrigerant from a low-pressure chiller & a rupture disc on a low-pressure recovery vessel relieves at ____ psig - 10 / 15 Refrigerant recovery from a system using _______ or _______ starts with _________ removal & is followed by ______ recovery - R-11 or R-123 / liquid / vapor A SUBSTANTIAL AMOUNT OF _______ WILL REMAIN in the appliance after all _________ is removed - vapor / liquid An AVERAGE 350 TON, R-123 CHILLER AT 0 PSIG STILL CONTAINS APPROXIMATELY ______ LBS of ______ AFTER ALL THE _________ HAS BEEN REMOVED - 100 / vapor / liquid Most low-pressure recovery machines utilize a water-cooled condenser that's connected to the: - potable or municipal water supply When recovering refrigerant, the system water pumps, the recovery compressor, & the RECOVERY CONDENSER WATER SHOULD ALL BE ON CIRCULATING WATER TO PREVENT: - freezing INCREASING THE TEMPERATURE in an equipment room WILL AID IN FASTER: - recovery A chiller is suspected of tubes leaks, the water sides of the ______________ & ______________ should be drained prior to recovering the refrigerant - evaporator & condenser ASHRAE Guideline 3 states that if the pressure in a system rises from ___ mm Hg to a level above _____ mm Hg during vacuum testing, the system should be leaked checked - 1 / 2.5 When REMOVING OIL FROM A LOW-PRESSURE SYSTEM, a tempt of _______ °F should be ATTAINED TO REDUCE THE AMOUNT OF REFRIGERANT IN THE OIL - 130 Refrigerant is added through the ___________ access point on the system such as the ____________ valve. HOWEVER, introducing ________ refrigerant into a deep vacuum will cause the refrigerant to _____ freezing water in the tubes - lowest / evaporator / liquid / boil Initial charging is in the _______ phase to a pressure _____ enough to increase the saturation tempt of refrigerant above the ____________ tempt of water - vapor / high / freezing Low-pressure refrigeration systems with refrigerants such as ________ REQUIRE A VAPOR PRESSURE EQUAL TO A SATURATION TEMPT OF _____°F OR HIGHER, TO PREVENT FREEZING of water-tubes when charging - R-123 / 36 Topping off a system: - adding refrigerant due to a leak & must be accounted for in the leak-rate calculation Adding refrigerant to a system that's ______, retrofitted, or adjusted for seasonal variance does not need to be accounted for in the leak-rate calculation - new Recovery or recycling equipment manufactured or imported before or after 11/15/93, must be able to achieve a recovery level of: - 25 mm Hg absolute Once the required vacuum has been achieved, the technician should wait for a few minutes & monitor the system: - pressure If the pressure ________, indicating that there's refrigerant remaining in the system, recovery must be: - rises / repeated When leaks in an appliance make EVACUATION to the prescribed level ___________, the appliance should be evacuated to the lowest attainable level prior to a: - unattainable / major repair To use of a LARGE VACUUM PUMP could cause trapped water to: - freeze During EVACUATION of systems with large amounts of ________, it may be necessary to increase pressure by introducing __________ to counteract freezing - water / nitrogen If a strong odor is detected during the recovery process, a ______________ ______-____ may have occurred - compressor burn-out When recovering refrigerant from a system that experienced a compressor burn-out, watch for signs of contamination in the ____ & perform an oil test - oil / Low-pressure chillers using R-123 operate below atmospheric pressure, require a: - purge unit What's the primary purpose of a purge unit? - removes non-condensables from the system A centrifugal chiller's purge unit takes its suction from the top of the _____________, separates air & other non-condensables from the refrigerant, & then returns the refrigerant back to the: - condenser / evaporator Although a high efficiency purge unit discharges a low percentage of refrigerant with the air they remove, frequent purging & subsequent refrigerant loss can indicate: - a leak is allowing air into the system High discharge pressure can indicate: - air in the system Excessive moisture collection in a purge unit can indicate: - tube leakage

Meer zien Lees minder
Instelling
EPA 608 - Type III
Vak
EPA 608 - Type III








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
EPA 608 - Type III
Vak
EPA 608 - Type III

Documentinformatie

Geüpload op
11 november 2024
Aantal pagina's
4
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

EPA 608 - TYPE III TEST AND VERIFIED ANSWERS

Technicians maintaining, servicing, repairing, or disposing of low-pressure appliances must
be certified as: - Type III or Universal Technician

The owner &/or operator of the equipment is responsible for keeping: - records including:
leak inspections & any completed leak repair verification tests

It's the _______ &/or ___________ responsibility to obtain service records from the servicing
company doing any work on an appliancem - owner &/ or operator

As of 11/14/94, the sale of _______ & _________ refrigerants is restricted to certified
technicians - CFC & HCFC

As of 1/1/18, the sale of _______ & ________ are also restricted to certified technicians - hfcs &
hfos

Low-pressure systems are semi-hermetic & operate below: - atmospheric pressure (in a
vacuum)

Leaks in the gaskets or fittings will cause ___ & _________ to enter the system - air & moisture

Leaks must be repaired to reduce the operation of the ________ unit & ______ of refrigerant -
purge / loss

Leak checking a charged, _____-__________ refrigeration unit is to pressurize the system using
controlled hot water or heater blankets - low-pressure

When controlled hot water or heater blankets are not feasible on leak checking a charged,
low-pressure unit, use __________ to increase system pressure - nitrogen

When pressurizing a system, don't exceed _____ psig - 10

Exceeding ____ psig can cause the rupture disk to fail - 10

When leak testing a _______ _____, be certain the water has been removed before placing the
leak detector probe through the: - water box / drain valve

To leak test a tube, use a ____________ tube test kit - hydrostatic

Systems with open drive compressors are prone to leaks at the: - shaft seal

Controlled hot water or heating blankets can be used to raise the pressure in a ______-
_________ for the purpose of opening the system for a: - low-pressure / non-major repair

What does a "major repair" under EPA regulations: - any maintenance, service, or repair
involving the removal of the following: compressor, condenser, evaporator, or any auxiliary
heat exchanger coil

Starting in 2019, EPA regulations require that systems containing more than _____ lbs of
refrigerant be repaired when the annual leak rate exceeds a ___________ of the refrigerant
charge - 50 / percentage

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TOPDOCTOR Abacus College, Oxford
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
10
Lid sinds
2 jaar
Aantal volgers
5
Documenten
3393
Laatst verkocht
1 maand geleden
TOPGRADER!!

Looking for relevant and updated study material to help you ace your exams? TOPTIERGRADES has your back!!! I have essential exams, test-banks, study bites, assignments all graded A+, Have Complete solutions, and are updated regularly. Please feel free to message me if you are looking for a specific test bank that is not listed on my profile or want a test bank or exam sent to you directly as google doc link. In the event that any of the materials have an issue, please let me know and I\'ll do my best to resolve it or provide an alternative. Thank You & All The Very BEST!!!!!

Lees meer Lees minder
5,0

1 beoordelingen

5
1
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen