Electrical Level 3 Module 1 Load Calculations and Branch Feeder Circuits questions and 100% verified correct answers According to the NEC®, the ampacity of branch circuit conductors must be derated when there are more than how many current-carrying conductors in a raceway? - Correct Answer 3 Air conditioning overcurrent protective devices can never exceed what percentage of the motor-rated load current or the branch circuit selection current (whichever is greater)? - Correct Answer 225% Conductors must be derated when installed in conduit - Correct Answer on or above rooftops Continuous loads are calculated at what percentage of the maximum current rating of the overcurrent device? - Correct Answer 80% For a given load and length, the branch circuit voltage drop should not exceed - Correct Answer 3% For resistance welders, the rating for the overcurrent protection device should not exceed what percentage of the primary current rating of the welder? - Correct Answer 300% Show window lighting is calculated at 200VA per linear foot plus - Correct Answer 125% The allowable ampacity for eleven No. 12 THHN copper conductors in a cable must be adjusted by - Correct Answer 50% The load for 10' of multi-outlet assembly used to supply several loads simultaneously is - Correct Answer 1,800VA The maximum size dual-element fuse for a 40hp, 3Ø, 460V motor with a Design Letter D is - Correct Answer 100A What is the demand load for one household range with a nameplate rating of 11.75kW, 240V, 1Ø? - Correct Answer 8kW What is the current-carrying capacity for No. 6 THWN aluminum conductors in conduit run through an ambient temperature of 38°C? - Correct Answer 44 Amps What is the lighting load on a 120V circuit for six 100W incandescent lights and four fluorescent fixtures with a ballast rating of 1.5A, all operating continuously for 8 hours per day? 13.75A - Correct Answer 13.75A What is the load center distance for a 208V, four-wire, three-phase branch circuit with fixed noncontinuous loads from the source of 60A at 45', 40A at 60', 30A at 75', and 25A at 100' - Correct Answer 63.55' What is the load center length for a branch circuit consisting of noncontinuous loads of 125A at 80', 75A at 110', and 50A at 100'? - Correct Answer 93' What is the load center length for a branch circuit with noncontinuous loads of 20A at 60' and 50A at 125'? - Correct Answer 106.43' What is the load for 55' of show window using the linear foot method? - Correct Answer 13,750VA

Meer zien Lees minder
Instelling
Ahip
Vak
Ahip








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Ahip
Vak
Ahip

Documentinformatie

Geüpload op
7 november 2024
Aantal pagina's
2
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Electrical Level 3 Module 1 Load Calculations
and Branch Feeder Circuits questions and 100%
verified correct answers
According to the NEC®, the ampacity of branch circuit conductors must be derated
when there are more than how many current-carrying conductors in a raceway? -
Correct Answer 3
Air conditioning overcurrent protective devices can never exceed what percentage of
the motor-rated load current or the branch circuit selection current (whichever is
greater)? - Correct Answer 225%
Conductors must be derated when installed in conduit - Correct Answer on or above
rooftops
Continuous loads are calculated at what percentage of the maximum current rating of
the overcurrent device? - Correct Answer 80%
For a given load and length, the branch circuit voltage drop should not exceed - Correct
Answer 3%
For resistance welders, the rating for the overcurrent protection device should not
exceed what percentage of the primary current rating of the welder? - Correct Answer
300%
Show window lighting is calculated at 200VA per linear foot plus - Correct Answer 125%
The allowable ampacity for eleven No. 12 THHN copper conductors in a cable must be
adjusted by - Correct Answer 50%
The load for 10' of multi-outlet assembly used to supply several loads simultaneously is
- Correct Answer 1,800VA
The maximum size dual-element fuse for a 40hp, 3Ø, 460V motor with a Design Letter
D is - Correct Answer 100A
What is the demand load for one household range with a nameplate rating of 11.75kW,
240V, 1Ø? - Correct Answer 8kW
What is the current-carrying capacity for No. 6 THWN aluminum conductors in conduit
run through an ambient temperature of 38°C? - Correct Answer 44 Amps
What is the lighting load on a 120V circuit for six 100W incandescent lights and four
fluorescent fixtures with a ballast rating of 1.5A, all operating continuously for 8 hours
per day? 13.75A - Correct Answer 13.75A
What is the load center distance for a 208V, four-wire, three-phase branch circuit with
fixed noncontinuous loads from the source of 60A at 45', 40A at 60', 30A at 75', and 25A
at 100' - Correct Answer 63.55'
What is the load center length for a branch circuit consisting of noncontinuous loads of
125A at 80', 75A at 110', and 50A at 100'? - Correct Answer 93'
What is the load center length for a branch circuit with noncontinuous loads of 20A at
60' and 50A at 125'? - Correct Answer 106.43'
What is the load for 55' of show window using the linear foot method? - Correct Answer
13,750VA
€9,55
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
comfortwanjau

Maak kennis met de verkoper

Seller avatar
comfortwanjau Abraham Lincoln University, School Of Law
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
0
Lid sinds
1 jaar
Aantal volgers
0
Documenten
111
Laatst verkocht
-

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen