Sonographers should be aware of work-related musculoskeletal disorders. Best practice while scanning is to avoid abducting the arm more than how many degrees? a. 50 b. 90 c. 30 d. 40 -Correct Answer c. 30 Which action demonstrates best practice during ultrasound exams regarding the ALARA principle? a. The exposure time should be extended during the exam. b. use the lowest possible output power that provides a diagnostic image. c. use the lowest possible gain. d. Ensure that the time gain compensation (TGC is within acceptable limits. -Correct Answer b. use the lowest possible output power that provides a diagnostic image Which type of cavitation is the most concerning cause of bioeffects? a. Transient b. Absorption c. Stable d. Thermal -Correct Answer a. transient Assuming an unfocused ultrasound beam, the American Institute of ultrasound in Medicine's "statement on Mammalian Biological Effects of ultrasound In vivo" has confirmed that no bioeffects have been noted when the spatial pulse temporal average (SPTA) intensity is less than which value? a. 1 mW/cm2 b. 100 W/cm2 c. 1 W/cm2 d. 100 mW/cm2 -Correct Answer d. 100 mW/cm2 A sonographer notices that the mechanical index (MI) is too high during an ultrasound. What would be the MOST appropriate modification that the sonographer can make? a. decrease receiver gain b. increase period c. decrease the output power d. decrease the frequency of the transducer -Correct Answer c. decrease the output power Select the technique that will generate the LEAST amount of exposure to the patient. a. Spectral Doppler b. Color flow Doppler c. Grayscale d. M-mode -Correct Answer c. grayscale When a vibrating string or fluid pump is used to test system performance, what parameter is being tested? a. Dead zone b. Doppler velocities c. Contrast resolution d. Grayscale sensitivity -Correct Answer b. Doppler velocities A tissue-equivalent phantom is used to ensure the efficiency of the ultrasound machine. Choose the resolution that is NOT tested with this phantom. a. Temporal b. Contrast c. Axial d. Horizontal -Correct Answer a. temporal Which performance check describes the ability of the ultrasound machine to correctly visualize signals that are weaker than others? a. Accuracy b. Specificity c. Reliability d. Sensitivity -Correct Answer d. sensitivity What is the name of the recent technological advancement that is used on tissues such as the liver, breast, prostate, and thyroid to assess the stiffness of tissue or to better assess lesions? a. Contrast-enhanced ultrasound b. Fusion imaging c. Elastography d. Harmonics -Correct Answer c. elastography Which choice is NOT a true statement regarding this filling defect within the gallbladder? a. The filling defect displays a significant amount of attenuation. b. it has created an enhancement artifact. c. It has created a shadowing artifact d. Regions deeper than the filling defect are obscured. -Correct Answer b. it has created an enhancement artifact Which type of artifact appears echogenic and stems from gas bubbles as they vibrate due to the interaction with the ultrasound beam? a. Ring-down artifact b. edge shadow c. Crosstalk d. Slice thickness -Correct Answer a. ring-down artifact

Meer zien Lees minder
Instelling
ARDMS .
Vak
ARDMS .










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
ARDMS .
Vak
ARDMS .

Documentinformatie

Geüpload op
1 november 2024
Aantal pagina's
16
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

ARDMS Abdomen Exam



ARDMS practice test questions and
answers 2024-2025
Sonographers should be aware of work-related musculoskeletal disorders. Best practice
while scanning is to avoid abducting the arm more than how many degrees?
a. 50
b. 90
c. 30
d. 40 -Correct Answer ✔c. 30

Which action demonstrates best practice during ultrasound exams regarding the ALARA
principle?
a. The exposure time should be extended during the exam.
b. use the lowest possible output power that provides a diagnostic image.
c. use the lowest possible gain.
d. Ensure that the time gain compensation (TGC is within acceptable limits. -Correct
Answer ✔b. use the lowest possible output power that provides a diagnostic image

Which type of cavitation is the most concerning cause of bioeffects?
a. Transient
b. Absorption
c. Stable
d. Thermal -Correct Answer ✔a. transient

Assuming an unfocused ultrasound beam, the American Institute of ultrasound in
Medicine's "statement on Mammalian Biological Effects of ultrasound In vivo" has
confirmed that no bioeffects have been noted when the spatial pulse temporal average
(SPTA) intensity is less than which value?
a. 1 mW/cm2
b. 100 W/cm2
c. 1 W/cm2
d. 100 mW/cm2 -Correct Answer ✔d. 100 mW/cm2

A sonographer notices that the mechanical index (MI) is too high during an ultrasound.
What would be the MOST appropriate modification that the sonographer can make?
a. decrease receiver gain
b. increase period
c. decrease the output power
d. decrease the frequency of the transducer -Correct Answer ✔c. decrease the output
power

Select the technique that will generate the LEAST amount of exposure to the
patient.
a. Spectral Doppler


ARDMS Abdomen Exam

,ARDMS Abdomen Exam


b. Color flow Doppler
c. Grayscale
d. M-mode -Correct Answer ✔c. grayscale

When a vibrating string or fluid pump is used to test system performance,
what parameter is being tested?
a. Dead zone
b. Doppler velocities
c. Contrast resolution
d. Grayscale sensitivity -Correct Answer ✔b. Doppler velocities

A tissue-equivalent phantom is used to ensure the efficiency of the
ultrasound machine. Choose the resolution that is NOT tested with this
phantom.
a. Temporal
b. Contrast
c. Axial
d. Horizontal -Correct Answer ✔a. temporal

Which performance check describes the ability of the ultrasound machine
to correctly visualize signals that are weaker than others?
a. Accuracy
b. Specificity
c. Reliability
d. Sensitivity -Correct Answer ✔d. sensitivity

What is the name of the recent technological advancement that is used on tissues such
as the liver, breast, prostate, and thyroid to assess the stiffness of tissue or to better
assess lesions?
a. Contrast-enhanced ultrasound
b. Fusion imaging
c. Elastography
d. Harmonics -Correct Answer ✔c. elastography

Which choice is NOT a true statement regarding this filling defect within the gallbladder?
a. The filling defect displays a significant amount of attenuation.
b. it has created an enhancement artifact.
c. It has created a shadowing artifact
d. Regions deeper than the filling defect are obscured. -Correct Answer ✔b. it has
created an enhancement artifact

Which type of artifact appears echogenic and stems from gas bubbles as they vibrate
due to the interaction with the ultrasound beam?
a. Ring-down artifact
b. edge shadow
c. Crosstalk

ARDMS Abdomen Exam

, ARDMS Abdomen Exam


d. Slice thickness -Correct Answer ✔a. ring-down artifact

What is the fundamental reason that the power and intensity of the ultrasound beam
diminish as it travels through tissue?
a. Absorption
b. Cavitation
c. Obstruction
d. Acoustic impedance -Correct Answer ✔a. absorption

Select the modification that the sonographer can make to decrease the amount of
attenuation as the ultrasound beam travels through tissues.
a. Increase the imaging depth.
b. Increase the frequency of the transducer.
c. Decrease the output power.
d. Decrease the frequency of the transducer. -Correct Answer ✔d. decrease the
frequency of the transducer

Choose the ultrasound system function that enables the sonographer to
adapt to the amount of attenuation that occurs with increasing depth.
a. Focusing
b. Receiver gain
c. TGC
d. Output power -Correct Answer ✔c. TGC

Assume that a sound beam is traveling in soft tissue. Calculate the
attenuation coefficient if the frequency is 12 MHz.
a. 12dB/cm
b. 6 dB/cm
c. 8 dB/cm
d. 10 dB/cm -Correct Answer ✔b. 6 dB/cm

What is NOT a component of attenuation?
a. Reflection
b. Scattering
c. Resolution
d. Absorption -Correct Answer ✔c. resolution

Impedance is NOT influenced by which component?
a. The frequency of the transducer
b. Density
c. Propagation speed
d. Stiffness -Correct Answer ✔a. the frequency of the transducer

For reflection to take place, which situation must exist?
a. The border of two different tissues must have different impedances.


ARDMS Abdomen Exam
€13,22
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
PossibleA Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
988
Lid sinds
4 jaar
Aantal volgers
650
Documenten
12721
Laatst verkocht
1 dag geleden
POSSIBLEA QUALITY UPDATED EXAMS

Choose quality study materials for nursing schools to ensure success in your studies and future career. "Welcome to PossibleA - your perfect study assistant! Here you will find Quality sheets, study materials, exams, quizzes, tests, and notes to prepare for exams and study successfully. Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers and checked for quality. Our quality sheets are an easy and quick way to remember key points and definitions. And our study materials, tests, and quizzes will help you absorb the material and prepare for exams. Our store also has notes and lecture summaries that will help you save time and make the learning process more efficient.

Lees meer Lees minder
3,9

141 beoordelingen

5
74
4
25
3
20
2
1
1
21

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen