100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

California Fluoroscopy Test Questions and Answers- 100% pass

Beoordeling
-
Verkocht
2
Pagina's
107
Cijfer
A+
Geüpload op
16-10-2024
Geschreven in
2024/2025

California Fluoroscopy Test Questions and Answers- 100% pass An image intensifiers photocathode causes ___ to be given off in direct proportion to the intensity of the fluorescent light: a. remnant radiation b. electrons c. x-rays d. light photons - Answer-electrons What fluoroscopic television system device decodes the video signal into a visible image? a. Vidicon camera b. Camera control unit c. Television monitor d. Electron gun - Answer-Television Monitor Which of the following materials are used in the construction of a fluoroscopic tabletop? 1. Lead 2. Aluminum EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 2/107 3. Bakelite 4. Carbon fiber - Answer-2, 3, and 4 Geometric factors in the shape of the image intensification tube b. Focal-film-distance (FFD) c. Object-to-image distance (OID) d. Minification gain - Answer-... If the entrance skin dose is measured from the surface of the tabletop, the x-ray source is located: a. either over or under the table b. under the table c. over the table d. not enough information provided - Answer-b. Under the table The mottle level of an image can be adjusted by: 1. changing mA 2. changing kVp 3. changing the exposure factors 4. increasing the number of available x-ray photons - Answer-All of the above EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 3/107 During a fluoroscopic exam, the main source of scattered radiation is produced from: a. the patient b. x-ray source c. table top d. leakage radiation - Answer-the patient Excessive lighting in the fluoroscopy room: a. Helps to perceive a dim image as brighter b. Helps to properly adjust the overall luminance of the TV image c. Enhances visualization of a black and white TV image d. May result in increasing the technical operating factors - Answer-May result in increasing the technical operating factors Suitable gonad shields must be used: a. Whenever gonads are within the useful x-raybeam b. When shielding of gonads does not interfere with the diagnosis c. On all potentially procreative patients d. At all times - Answer-When shielding of gonads does not interfere with the diagnosis Which of the following are true concerning cine film? EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 4/107 1. Available film sizes are: 70 mm, 100 mm, and 110 mm 2. The larger the film size the better the image quality 3. Nearly all cine-fluorography exams involve studies of the GI system 4. Delivers approximately the same dose as routine photospot image recording - Answer-2 only The exposure rate at the tabletop may not exceed five rads per minute except: 1. when using the ABC on large patients 2. during magnification mode 3. where higher exposure rates are allowed - Answer-b. 1, 2 and 3 only Images produced with photo spot film cameras ___ spot films taken with conventional cassettes. 1. use a higher mA than 2. require about 1/2 to 1/3 the dose of 3. exhibit superior image quality compared to - Answer-require about 1/2 to 1/3 the dose The ability of an imaging system to differentiate small objects that are closely spaced as separate objects is referred to as: a. Differentiation b. Resolution EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 5/107 c. Statistical fluctuation d. Detector contrast - Answer-b. Resolution The photoconductive target in a television camera pick-up tube: a. Conducts electrons across to the target b. Allows a proportional electron charge to be generated at a particular position c. Creates a video signal d. Creates an electronic current which is converted into a video image . - Answer-Allows a proportional electron charge to be generated at a particular position Size distortion is primarily caused by: a. Focal-film-distance (FFD) b. Geometric factors in the shape of the image intensification tube c. Minification gain d. Object-to-image distance (OID) - Answer-Object-to-image distance (OID) The overall luminescence of the TV image may be properly adjusted by: 1. increasing room lighting 2. adjusting the contrast control button on the TV monitor EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 6/107 3. adjusting the brightness control button on the TV monitor - Answer-2 and 3 only Which of the following statements is true concerning fluoroscopic grids? a. Reduces scattered radiation produced in the image intensifier b. The typical grid ratio is 12:1 c. High ratio grids are preferred d. Located between the patient and input layer of the image intensifier - Answer-Located between the patient and input layer of the image intensifier One of the most important actions a fluoroscopist can take to avoid unnecessary radiation exposure to the patient is to use appropriate: a. Illumination b. Primary beam filtration c. Collimation d. Protective lead curtains - Answer-Collimation The increase in effective brightness due to the size reduction

Meer zien Lees minder
Instelling
Fluoroscopy
Vak
Fluoroscopy











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Fluoroscopy
Vak
Fluoroscopy

Documentinformatie

Geüpload op
16 oktober 2024
Aantal pagina's
107
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024




California Fluoroscopy Test Questions
and Answers- 100% pass

An image intensifiers photocathode causes ___ to be given off in direct proportion to the

intensity of the fluorescent light:


a. remnant radiation


b. electrons


c. x-rays


d. light photons - Answer✔✔-electrons


What fluoroscopic television system device decodes the video signal into a visible image?


a. Vidicon camera


b. Camera control unit


c. Television monitor


d. Electron gun - Answer✔✔-Television Monitor


Which of the following materials are used in the construction of a fluoroscopic tabletop?


1. Lead


2. Aluminum

Page 1/107

,EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


3. Bakelite


4. Carbon fiber - Answer✔✔-2, 3, and 4


Geometric factors in the shape of the image intensification tube


b. Focal-film-distance (FFD)


c. Object-to-image distance (OID)


d. Minification gain - Answer✔✔-...


If the entrance skin dose is measured from the surface of the tabletop, the x-ray source is

located:


a. either over or under the table


b. under the table


c. over the table


d. not enough information provided - Answer✔✔-b. Under the table


The mottle level of an image can be adjusted by:


1. changing mA


2. changing kVp


3. changing the exposure factors


4. increasing the number of available x-ray photons - Answer✔✔-All of the above



Page 2/107

,EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


During a fluoroscopic exam, the main source of scattered radiation is produced from:


a. the patient


b. x-ray source


c. table top


d. leakage radiation - Answer✔✔-the patient


Excessive lighting in the fluoroscopy room:


a. Helps to perceive a dim image as brighter


b. Helps to properly adjust the overall luminance of the TV image


c. Enhances visualization of a black and white TV image


d. May result in increasing the technical operating factors - Answer✔✔-May result in increasing

the technical operating factors


Suitable gonad shields must be used:


a. Whenever gonads are within the useful x-raybeam


b. When shielding of gonads does not interfere with the diagnosis


c. On all potentially procreative patients


d. At all times - Answer✔✔-When shielding of gonads does not interfere with the diagnosis


Which of the following are true concerning cine film?



Page 3/107

, EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


1. Available film sizes are: 70 mm, 100 mm, and 110 mm


2. The larger the film size the better the image quality


3. Nearly all cine-fluorography exams involve studies of the GI system


4. Delivers approximately the same dose as routine photospot image recording - Answer✔✔-2

only


The exposure rate at the tabletop may not exceed five rads per minute except:


1. when using the ABC on large patients


2. during magnification mode


3. where higher exposure rates are allowed - Answer✔✔-b. 1, 2 and 3 only


Images produced with photo spot film cameras ___ spot films taken with conventional

cassettes.


1. use a higher mA than


2. require about 1/2 to 1/3 the dose of


3. exhibit superior image quality compared to - Answer✔✔-require about 1/2 to 1/3 the dose


The ability of an imaging system to differentiate small objects that are closely spaced as

separate objects is referred to as:


a. Differentiation


b. Resolution


Page 4/107
€10,93
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Emillect West Virginia University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
28
Lid sinds
1 jaar
Aantal volgers
2
Documenten
3004
Laatst verkocht
1 maand geleden
GOLDEN ORCHIDS STORE.

On this page, you find all documents, package deals, and flashcards offered by seller Emillect.

3,0

4 beoordelingen

5
1
4
0
3
2
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen