TT 345-750V - CORRECT ANSWER-16ft TT TA 500-750V - CORRECT ANSWER-35ft TA TT 50-345V - CORRECT ANSWER-10ft TT TA 750-1000V - CORRECT ANSWER-45ft TA TA 50-200V - CORRECT ANSWER-15ft TA TA 350-500V - CORRECT ANSWER-25ft TA TT 750-1000 - CORRECT ANSWER-20ft TT TT .01-.75 - CORRECT ANSWER-4ft TT TA 200-350V - CORRECT ANSWER-20ft TA TA up to 50V - CORRECT ANSWER-10ft TA TT .75-50V - CORRECT ANSWER-6ft TT How many electrocution hazard warnings must be displayed - CORRECT ANSWER-1 in cab 2 outside Using Running wire rope, ________ randomly distributed broken wires in ________ rope lay - CORRECT ANSWER-6-1

Meer zien Lees minder
Instelling
NCCCO CORE Including Tables
Vak
NCCCO CORE including tables










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
NCCCO CORE including tables
Vak
NCCCO CORE including tables

Documentinformatie

Geüpload op
12 oktober 2024
Aantal pagina's
16
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

NCCCO CORE including tables Exam
Questions & Answers Scored A+
TT 345-750V - CORRECT ANSWER-16ft TT



TA 500-750V - CORRECT ANSWER-35ft TA



TT 50-345V - CORRECT ANSWER-10ft TT



TA 750-1000V - CORRECT ANSWER-45ft TA



TA 50-200V - CORRECT ANSWER-15ft TA



TA 350-500V - CORRECT ANSWER-25ft TA



TT 750-1000 - CORRECT ANSWER-20ft TT



TT .01-.75 - CORRECT ANSWER-4ft TT



TA 200-350V - CORRECT ANSWER-20ft TA



TA up to 50V - CORRECT ANSWER-10ft TA



TT .75-50V - CORRECT ANSWER-6ft TT



How many electrocution hazard warnings must be displayed - CORRECT ANSWER-1
in cab 2 outside

,Using Running wire rope, ________ randomly distributed broken wires in ________
rope lay - CORRECT ANSWER-6-1



________ broken wires in one STRAND in______ rope lay - CORRECT ANSWER-3-1



In rotation resistant ropes, _______ randomly distributed broken wires in _______ rope
diameters or ______ randomly distributed broken wires in _____ rope diameters. -
CORRECT ANSWER-2-6, 4-30



In Pendants or standing wire ropes more than ____ broken wires in one rope lay
located in rope BEYOND end connections and/or more than ____ broken wire in rope
lay located at an end connection - CORRECT ANSWER-2-1



What is the Load Angle Factor if Horizontal Sling Angle Factor is 90 degrees -
CORRECT ANSWER-1.000



What is the Load Angle Factor if Horizontal sling angle is 60 degrees - CORRECT
ANSWER-1.155



What is the Load Angle Factor if Horizontal Sling Angle Factor 30 degrees - CORRECT
ANSWER-2.000



What is strongest type of sling - CORRECT ANSWER-Basket



What is the second strongest sling - CORRECT ANSWER-Vertical



What is the weakest sling - CORRECT ANSWER-Choker



Rated capacity of Angle of choke over 120 - CORRECT ANSWER-100



Rated capacity of Angle of choke 90-120 - CORRECT ANSWER-87

, Rated capacity of Angle of choke 60-89 - CORRECT ANSWER-74



Rated capacity of Angle of choke 30-59 - CORRECT ANSWER-62



Rated capacity of Angle of choke 0-29 - CORRECT ANSWER-49



What is the OSHA standard that covers the construction industry? - CORRECT
ANSWER-CFR 1926.1400



What is the ASME/ANSI standard for mobile cranes - CORRECT ANSWER-B30.5



Inspections every shift - CORRECT ANSWER-By a competent person and no
document needed



Monthly inspection - CORRECT ANSWER-Competent person documented for 3 months



Annual inspection - CORRECT ANSWER-Qualified person documented for a year



When should taglines be used - CORRECT ANSWER-When load is dangerous



When hoisting personnel, within what percentage of level must a telescopic boom need
to be at - CORRECT ANSWER-1%



What do you do if a crane has been energized but no sign of fire exists - CORRECT
ANSWER-Stay in cab until de-energized



Net capacity of cranes main boom - CORRECT ANSWER-Capacity listed in load chart
minus rigging and all attachments



What area do truck cranes without a 5th outrigger have no lifting capacity - CORRECT
ANSWER-Over the Front
€9,99
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
Vaster
5,0
(2)

Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
Vaster Stanford University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
4
Lid sinds
1 jaar
Aantal volgers
1
Documenten
794
Laatst verkocht
1 maand geleden

5,0

2 beoordelingen

5
2
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen