BACKFLOW PREVENTION ASSEMBLY TESTER (BPAT) EXAM LATEST 2025 ACTUAL EXAM COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+

Instelling
BACKFLOW PREVENTION ASSEMBLY TESTER
Vak
BACKFLOW PREVENTION ASSEMBLY TESTER










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
BACKFLOW PREVENTION ASSEMBLY TESTER
Vak
BACKFLOW PREVENTION ASSEMBLY TESTER

Documentinformatie

Geüpload op
7 oktober 2024
Aantal pagina's
25
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

BACKFLOW PREVENTION ASSEMBLY
TESTER (BPAT) EXAM LATEST 2025
ACTUAL EXAM COMPLETE QUESTIONS
AND CORRECT DETAILED ANSWERS
(VERIFIED ANSWERS) |ALREADY GRADED
A+


If not marked, a pressure vacuum breaker's critical level is ____?
A. At the bottom of the valve body
B. Measured from the check valve inlet
C. Measured from the body outlet
D. Not important
E. The air-inlet valve opening Correct Answer At the bottom of
the valve body

A pressure vacuum breaker may have ____ on the assembly's
discharge piping.
A. Auxiliary water supply looped irrigation
B. A boiler
C. A booster pump
D. Elevated piping
E. Irrigation sprinkler heads Correct Answer Irrigation sprinkler
heads

The minimum loading to open a pressure vacuum breaker's air-
inlet valve is ____?
A. 1 psi (6.89 kPa)
B. 2 psi (13.8 kPa)
C. 3 psi (20.7 kPa)
D. 4 psi (27.6 kPa)

,E. 5psi (34.5 kPa) Correct Answer 1 psi (6.89 kPa)

The recorded value of a pressure vacuum breaker check valve is
determined when ____?
A. Both shut-off valves are closed
B. The high-bleed valve is opened
C. The air-inlet valve opens
D. Water stops flowing from test cock 1
E. Water stops flowing from test cock 2 Correct Answer Water
stops flowing from test cock 2

Pressure vacuum breaker shut-off valves must be _____ valves.
A. Angle
B. Gate
C. Globe
D. Regulating
E. Tightly closed Correct Answer Tightly closed

An indication that a pressure vacuum breaker is undersized for its
application is _____?
A. Air-inlet valve leakage
B. Bonnet distortion
C. Chatter or noise during flow
D. Disc pitting
E. Spring elongation Correct Answer Chatter or noise during flow

Continuous flow from a pressure vacuum breaker's test cock 2
with shut-off valve 2 open and shut-off valve 1 closed is an
indication of _____?
A. Backpressure backflow
B. Backsiphonage backflow
C. A failed air-inlet valve
D. A leaking check valve
E. A leaking or damaged shut-off valve 1 Correct Answer
Backpressure backflow

, Pressure vacuum breakers may be used on the following
applications except ____?
A. High hazard/backsiphonage
B. High hazard/continuous pressure
C. Low hazard/backpressure
D. Low hazard/backsiphonage
E. Low hazard/intermittent pressure Correct Answer Low
hazard/backpressure

A double check valve assembly is installed 12 in. (30.5 cm) above
the floor for _____?
A. Electrical code compliance
B. Floor draining
C. Maintenance
D. Mechanical code compliance
E. Rodent control Correct Answer Maintenance

Double check valve assembly product performance standards
require venting for _____?
A. Chemicals
B. Test cock corrosion
C. Trapped air
D. Vertical installations
E. Winterization Correct Answer Trapped air

A low-hazard use only backflow preventer is a(n) _____?
A. Air-gap separation
B. Atmospheric vacuum breaker
C. Double check valve assembly
D. Pressure vacuum breaker assembly
E. Reduced pressure principle assembly Correct Answer Double
check valve assembly
€19,96
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
mnyawira477
1,0
(1)

Maak kennis met de verkoper

Seller avatar
mnyawira477 Chamberlain College Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
7
Lid sinds
1 jaar
Aantal volgers
0
Documenten
347
Laatst verkocht
6 maanden geleden

Hello there, I am an experienced tutor and I am here to provide you with your study solutions ranging from exams, studyguides,essays,notes and just to make school a little bit easier for you .I also offer the best quality and reliable study material . Engage me if you have any questions about your course and i will swiftly and gladly assist .Good luck with studying and all the best going forward .

1,0

1 beoordelingen

5
0
4
0
3
0
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen