EPA 608 Study Guide Questions With Revised Correct Answers BEST UPDATED!! Where would you place a leak detector probe to check gas leaks into the water box with water removed - ANSWER the drain valve opening In Which of the following indicates air in a low pressure system - ANSWER High head pressure A hydrostatic tube test kit will - ANSWER tube leaks Determine if a When leak testing a low pressure centrifugal chiller with nitrogen what is the maximum test pressure - ANSWER psig A ruptured disc on a recovery vessel for low pressure refrigerant relieves at - ANSWER 15 psig 10 On low pressure chillers moisture most frequently enters the refrigerant system through - ANSWER Leaks from areas with gaskets or fittings Excessive running of a purge system on a low pressure chiller generally indicates what condition - ANSWER Leaking system

Meer zien Lees minder
Instelling
EPA 608
Vak
EPA 608











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
EPA 608
Vak
EPA 608

Documentinformatie

Geüpload op
6 september 2024
Aantal pagina's
43
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

EPA 608 Study Guide Questions
With Revised Correct Answers
BEST UPDATED!!

Where would you place a leak detector probe to check gas
leaks into the water box with water removed - ANSWER In
the drain valve opening


Which of the following indicates air in a low pressure system -
ANSWER High head pressure


A hydrostatic tube test kit will - ANSWER Determine if a
tube leaks


When leak testing a low pressure centrifugal chiller with
nitrogen what is the maximum test pressure - ANSWER 10
psig


A ruptured disc on a recovery vessel for low pressure
refrigerant relieves at - ANSWER 15 psig

, On low pressure chillers moisture most frequently enters the
refrigerant system through - ANSWER Leaks from areas
with gaskets or fittings


Excessive running of a purge system on a low pressure chiller
generally indicates what condition - ANSWER Leaking
system


Pressure relief valves can only be installed - ANSWER In
parallel


Where should the discharge from a ruptured disc be piped for
venting - ANSWER Outdoors


what is the primary purpose of a purge unit on a low pressure
chiller - ANSWER Remove noncondensibles from the
system


A company uses a chiller that diverts 55% of its cooling
capacity to one of its manufacturing lines and 45% of its cooling
capacity to air condition the office spaces. Which leak rate
category would this chiller be in - ANSWER Industrial
process refrigeration

, Starting in 2019 what is the leak rate threshold for commercial
refrigeration equipment with a full charge of 50 or more
pounds of an HCFC refrigerant - ANSWER 0.2


Where does refrigerant go after it leaves the purge unit of a
low-pressure centrifugal system - ANSWER The evaporator


To determine if the system is leaking more than the allowable
rate The EPA allows the use of which one of the following
methods to determine the full charge - ANSWER Use of
calculations based on component and pipe sizes


ASHRAE Standard 15-2013 requires the use of room sensors
and alarms to detect - ANSWER Refrigerant leaks


Why do chillers using low pressure refrigerant require purge
units - ANSWER These systems operate below atmospheric
pressure


Why should the oil be removed from a low pressure system at
130°F - ANSWER Less refrigerant will be contained in the oil
the higher temperature

, The EPA's leak repair requirements apply to appliances with a
charge size of - ANSWER 50 pounds or greater


What is meant by the term "high efficiency purge unit" -
ANSWER Purge units that discharge a low percentage of
refrigerant with the air they removed


During evacuation with large amounts of moisture it may be
necessary to increase pressure to counteract freezing with gas
such as - ANSWER Nitrogen


A typical setting for the high pressure cut out control on a
recovery unit used for evacuating the refrigerant from a low-
pressure chiller is - ANSWER 10 psig


A chiller with a charge of 200 pounds of an ozone depleting
refrigerant has passed the initial verification leak test. When
must a follow up verification test be conducted - ANSWER
Within 10 days


Where is the rupture disc located on a centrifugal chiller -
ANSWER The evaporator

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ACADEMICWISEGIANT Walden University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
185
Lid sinds
3 jaar
Aantal volgers
119
Documenten
2771
Laatst verkocht
2 weken geleden
ONLINE STUDIES GURU

WE PROVIDE ACCURATE STUDY MATERIALS ALL AND EVERY TIME

4,2

48 beoordelingen

5
33
4
5
3
3
2
0
1
7

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen