Per NFPA 20 requirements, which of the following is required to illuminate a pump room or pump house. Correct Answer Artificial Light Before shipment from the factory, each pump shall be hydrostatically tested by the manufacturer. The test pressure shall not be less than one-half times the sum of the pump's shutoff heads plus its maximum allowable suction head, but shall not be less than, Correct Answer 200 PSI The weekly test for an electric pump requires the pump to run for a minimum of Correct Answer 10 Minutes The distance between the bottom of strainer and the bottom of the wet pit on a vertical shaft turbine pump should be: Correct Answer One half of the pump diameter but not less than 12 inches Engine generator sets supplying emergency or standby power to fire pump assemblies shall be periodically tested in accordance with which of the following NFPA standards: Correct Answer NFPA 110 A pump for fire protection shall be selected to operate at less than or equal to _% of the rated capacity. Correct Answer 150 A fire pump controller shall be permitted to be used as a junction box to supply other equipment. Correct Answer False Authority Having Jurisdiction (AHJ) is the organization, office, or individual responsible for approving equipment, materials, installations or procedures. Correct Answer True Which of the following conditions requires the installation of a listed indicating butterfly or gate valve and a drain valve or ball drip located in the pipeline to the hose valve header: Correct Answer Both A and B The maximum allowable shutoff head for a pump with a rated capacity of 900 gpm and a rated head of 250 feet is: Correct Answer 350 Feet Maximum number of drivers permitted to equip a fire pump is Correct Answer One Which of the following valves allows the diversion of liquid to limit excess pressure in a system: Correct Answer A relief valve

Meer zien Lees minder
Instelling
Fire Pump Ohio
Vak
Fire Pump Ohio








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Fire Pump Ohio
Vak
Fire Pump Ohio

Documentinformatie

Geüpload op
30 augustus 2024
Aantal pagina's
4
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Fire Pump Ohio Test Study Guide Questions
with Correct Answers
Per NFPA 20 requirements, which of the following is required to illuminate a pump room
or pump house. Correct Answer Artificial Light

Before shipment from the factory, each pump shall be hydrostatically tested by the
manufacturer. The test pressure shall not be less than one-half times the sum of the
pump's shutoff heads plus its maximum allowable suction head, but shall not be less
than, Correct Answer 200 PSI

The weekly test for an electric pump requires the pump to run for a minimum of Correct
Answer 10 Minutes

The distance between the bottom of strainer and the bottom of the wet pit on a vertical
shaft turbine pump should be: Correct Answer One half of the pump diameter but not
less than 12 inches

Engine generator sets supplying emergency or standby power to fire pump assemblies
shall be periodically tested in accordance with which of the following NFPA standards:
Correct Answer NFPA 110

A pump for fire protection shall be selected to operate at less than or equal to _% of the
rated capacity. Correct Answer 150

A fire pump controller shall be permitted to be used as a junction box to supply other
equipment. Correct Answer False

Authority Having Jurisdiction (AHJ) is the organization, office, or individual responsible
for approving equipment, materials, installations or procedures. Correct Answer True

Which of the following conditions requires the installation of a listed indicating butterfly
or gate valve and a drain valve or ball drip located in the pipeline to the hose valve
header: Correct Answer Both A and B

The maximum allowable shutoff head for a pump with a rated capacity of 900 gpm and
a rated head of 250 feet is: Correct Answer 350 Feet

Maximum number of drivers permitted to equip a fire pump is Correct Answer One

Which of the following valves allows the diversion of liquid to limit excess pressure in a
system: Correct Answer A relief valve

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ExamsGuru Grand Canyon University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
346
Lid sinds
2 jaar
Aantal volgers
203
Documenten
7694
Laatst verkocht
18 uur geleden
ExamsGuru

Before anything else, preparation is the key to success. We handle all kind of papers with accurate and complete solutions. Kindly send a direct message incase you miss what you are looking for since we will deliver within the shortest time possible. We respond as soon as possible and give guidance accordingly. Refer 3 of Your Friends and get a discount on 2 papers.

3,7

64 beoordelingen

5
29
4
9
3
13
2
4
1
9

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen