100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

FDNY Z51 RMO Set Test Questions And Verified Correct Solutions | Updated

Beoordeling
-
Verkocht
-
Pagina's
58
Cijfer
A+
Geüpload op
01-08-2024
Geschreven in
2024/2025

FDNY Z51 RMO Set Test Questions And Verified Correct Solutions | Updated The efficiency of the refrigerant cycle is affected by the operation of the condenser. Of the following, a more efficient centrifugal compressor operation results from: a. Raising the condenser liquid level to the maximum b. Lowering the chilled water set point c. Raising the condenser head pressure d. Lowering the condensing pressure d. Lowering the condensing pressure The heat removed from the refrigerant in a condenser is: a. Sensible and latent heat b. Latent heat only c. Radiant heat only d. Sensible heat only a. Sensible and latent heat The refrigerant unit that you have been assigned to is being taken out of service for a major repair. You have been assigned to withdraw refrigerant for storage in suitable containers. According to the New York City fire code, you must ensure that the containers: a. Do not weight more than 200 pounds when filled b. Are approved by the US Department of Transportation c. Are approved by the OSHA Association d. Do not exceed 55 Gallon in capacity b. Are approved by the US Department of Transportation Which of the following best describes how the cylinder unloader work? a. Keep in the suction valve opened while the compressor is in the return stroke b. Controls the clearance volume in the compressor with a solenoid c. Controls the opening of the passage into the compressor with variable vanes d. Unloads the piston to create less pressure

Meer zien Lees minder
Instelling
FDNY Z51
Vak
FDNY Z51











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
FDNY Z51
Vak
FDNY Z51

Documentinformatie

Geüpload op
1 augustus 2024
Aantal pagina's
58
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

FDNY Z51 RMO Set Test Questions And Verified Correct Solutions | Updated The efficiency of the refrigerant cycle is affected by the operation of the condenser. Of the following, a more efficient centrifugal compressor operation results from : a. Raising the condenser liquid level to the maximum b. Lowering the chilled water set point c. Raising the condenser head pressure d. Lowering the condensing pressure d. Lowering the condensing pressure The heat removed from the refrigerant in a condenser is: a. Sensible and latent heat b. Latent heat only c. Radiant heat only d. Sensible heat only a. Sensible and latent heat The refrigerant unit that you have been assigned to is being taken out of service for a major repair. You have been assigned to withdraw refrigerant for storage in suitable containers. According to the New York City fire code, you must ensure that the containers: a. Do not weight more than 200 pounds when filled b. Are approved by the US Department of Transportation c. Are approved by the OSHA Association d. Do not exceed 55 Gallon in ca pacity b. Are approved by the US Department of Transportation Which of the following best describes how the cylinder unloader work? a. Keep in the suction valve opened while the compressor is in the return stroke b. Controls the clearance volume in the com pressor with a solenoid c. Controls the opening of the passage into the compressor with variable vanes d. Unloads the piston to create less pressure a. Keep in the suction valve opened while the compressor is in the return stroke In most semi Hermetic comp ressors, the suction vapor is used to: a. Removes oil from the motor housing b. Cools the motor c. Minimizes oil foaming d. Removes oil form from the shaft b. Cools the motor The amount of refrigerant that flows through the orifices of an a economizer is determined by the: a. Number of economizer stages b. Temperature of the high side refrigerant c. Number of compressor stages d. Difference between the high side and low side pr essure d. Difference between the high side and low side pressure The installation of an inline refrigerant cleaning system is advisable: a. For high pressure refrigerant systems b. To purge non -condensables c. For systems using toxic refrigerant d. To remo ve impurities from the system d. To remove impurities from the system The type of refrigerant system that is least likely to leak refrigerant into the building space that are being cooled: a. The direct vented closed system b. The direct closed system c. Any system using reciprocating compressor d. The indirect system d. The indirect system The suction pressure of a reciprocating compressor is 65 PSIG. The discharge pressure of this compressor is 120 PSIG. The atmospheric is 14.7 PSI. The compression ratio for the given condition is closet to: a. 2.07 b. 4.41 c. 1.69 d. 1.84 c. 1.69 A superheated vapor is a: a. Dry vapor at the saturation temperature b. Dry saturated vapor c. Dry vapor above the saturation temperature d. Vapor with minimal amount of included liquid c. Dry vapor above the saturation temperature A refrigerant engineer verifies that a condenser water pump is cavitating. Of the following, the most likely cause for this condition is: a. A faulty cooling tower water level controller b. Operating at sustaining high loads c. Too long a period between pump servicing d. Refrigerant leaks through the pumps packing a. A faulty cooling tower water level controller A centrifugal water pump is known as a lift pump when the: a. The pump lifts t he water in the pump upon startup b. The water supply to the pump suction inlet is below the pump level c. The discharge head exceed 150 feet d. The pump is started with the suction valve open b. The water supply to the pump suction inlet is below the pump level A TXV is used to maintain constant: a. Refrigerant flow b. Evaporator pressure c. Evaporator pressure drop d. Evaporator super heat d. Evaporator super heat The chilled water supply to the building is 55F. If the chiller is being used for human comfort, should you be concerned about this, and why? a. Yes, this temperate is too low for human comfort purpose b. Yes, this temperature is too high for human comfort purpose c. No, 55F is within are acceptable range d. No, temperate gauges often give false high readings b. Yes, this temperature is too high for human comfort purpose The packing gland of a centrifugal pump serves to: a. Keep the bearing cooled
€14,92
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
EWLindy Harvard University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
710
Lid sinds
3 jaar
Aantal volgers
431
Documenten
7425
Laatst verkocht
2 dagen geleden
EN.CY.CLO.PE.DI.A

As a Career Tutor, I understand the pressure of managing demanding coursework, exams, and practical requirements across multiple disciplines. These professionally organized revision materials are designed to support students in nursing, healthcare administration, business, information systems, Engineering, health, IT, or trade courses management programs by simplifying complex concepts and reinforcing high-yield academic content. The materials are developed to help students: Understand core theories and practical applications across Multiple Disciplines Review exam relevant content aligned with undergraduate and graduate curriculam To Strengthen critical thinking, analytical reasoning, and decision-making skills Save time with clear, structured summaries instead of overwhelming textbooks Prepare efficiently for tests, assignments, case studies, and professional exams Each resource is created with academic standards in mind, integrating real world examples, industry terminology, and evidence based concepts commonly required in professional programs. Whether you are studying nursing fundamentals, healthcare management, information systems, project management, business strategy, Engineering these materials provide focused, reliable support for academic success. These revision guides are ideal for: Nursing and allied health students Healthcare administration and public health students Business, MBA, and management students Information technology and information systems students, engineering, business, IT, or trade courses If you are looking for clear, student-friendly, exam-focused revision materials that support multiple career pathways, these resources are designed to help you study smarter, perform better, and stay confident throughout your academic journey. WISH YOU SUCCESS!!

Lees meer Lees minder
3,8

107 beoordelingen

5
55
4
13
3
16
2
6
1
17

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen