100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

NATE AC Service Certification Questions & Answers Already Passed

Beoordeling
-
Verkocht
-
Pagina's
27
Cijfer
A+
Geüpload op
28-05-2024
Geschreven in
2023/2024

A system is supplied from the factory with charge of 5 pounds 10 ounces for a 15 foot line set. The line set is 25 feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigeration to be added for each added foot of refrigerant line set length. What is the total refrigerant charge for the system? A. 6 ounces B. 5 pounds C. 5 pounds 10 ounces D. 6 pounds - D. 6 pounds 15ft - 25ft = 10ft x .6 = 6 ounces 5 pounds + 10 ounces + 6 ounces 5 pounds + 16 ounces = 6 pounds The purpose of using flux when soldering is to: A. anneal the surface. B. give better heat flow. C. reduce oxidation. D. pre-seal the oxidation. - C. reduce oxidation. Outdoor condensing units that are installed in areas where flooding is possible must: A. be mounted above flood level. B. utilize NEMA 1 enclosures. C. be mounted under an overhanging eave. D. use water resistant components. - A. be mounted above flood level.The component used to reduce sound transmission and prevent water leaks on a rooftop air conditioner packaged unit installation is the: A. curb gasket. B. silicone caulk. C. roof flashing. D. roofing tar. - A. curb gasket.

Meer zien Lees minder
Instelling
NATE AC Service Certification
Vak
NATE AC Service Certification










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
NATE AC Service Certification
Vak
NATE AC Service Certification

Documentinformatie

Geüpload op
28 mei 2024
Aantal pagina's
27
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

NATE AC Service Certification A system is supplied from the factory with charge of 5 pounds 10 ounces for a 15 foot line set. The line set is 25 feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigeration to be added for each added foot of refrigerant line set length. What is the total refrigerant charge for the system? A. 6 ounces B. 5 pounds C. 5 pounds 10 ounces D. 6 pounds - D. 6 pounds 15ft - 25ft = 10ft x .6 = 6 ounces 5 pounds + 10 ounces + 6 ounces 5 pounds + 16 ounces = 6 pounds The purpose of using flux when soldering is to: A. anneal the surface. B. give better heat flow. C. reduce oxidation. D. pre -seal the oxidation. - C. reduce oxidation. Outdoor condensing units that are installed in areas where flooding is possible must: A. be mounted above flood level. B. utilize NEMA 1 enclosures. C. be mounted under an overhanging eave. D. use water resistant components. - A. be mounted above flood level. The component used to reduce sound transmission and prevent water leaks on a rooftop air conditioner packaged unit installation is the: A. curb gasket. B. silicone caulk. C. roof flashing. D. roofing tar. - A. curb gasket. Return air leakage in a hot attic will: A. Increase capacity B. Decrease capacity C. Increase airflow D. Decrease airflow - B. Decrease capacity An air conditioner refrigerant circuit should be evacuated to a minimum of: A. 0 microns. B. 200 microns. C. 500 microns. D. 1200 microns. - C. 500 microns. Which of the following substances could create an extremely dangerous condition if used to check refrigeration system for leaks? A. R-22 B. Nitrogen C. Oxygen D. Carbon Dioxide - D. Carbon Dioxide The subcooling method for checking charge is generally used on air conditioners with what type of metering? A. Only externally equalized thermostatic expansion valves B. Any thermostatic expansion valve C. Piston type D. Any fixed metering device - B. Any thermostatic expansion valve Supply ducts running through unconditioned space should be insulated and have: A. equal friction. B. excessive air velocity. C. a vapor barrier. D. a transition backing. - C. a vapor barrier. An important consideration when installing a motorized economizer is to check to be certain that: A. the vanes are set for a maximum 10% outdoor air. B. the vanes open on any call for cooling. C. the vanes operate without binding. D. the vanes are permanently set at 50%. - C. the vanes operate without binding. On a 3 ton unit installation, the measure airflow equals 1550 CFM. What does this indicate? A. Proper balancing B. Low Airflow C. Excess airflow D. Improper balancing - C. Excess airflow(400cfm per ton, 3 ton=1200cfm)
€7,53
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ACADEMICMATERIALS City University New York
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
569
Lid sinds
2 jaar
Aantal volgers
186
Documenten
10590
Laatst verkocht
14 uur geleden

4,1

96 beoordelingen

5
53
4
12
3
21
2
3
1
7

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen