100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

MIC-CT Registry Review-System Operations and Components Questions and Answers 100% Pass

Beoordeling
-
Verkocht
-
Pagina's
11
Cijfer
A+
Geüpload op
23-04-2024
Geschreven in
2023/2024

MIC-CT Registry Review-System Operations and Components Questions and Answers 100% Pass In order for an x-ray photon to be measured it must: - Correct Answer ️️ -Enter the detector chamber, be absorbed by the detector material and be converted to a measureable event Which system component converts the projection attenuation data into the proper digital form for the array processor? - Correct Answer ️️ -Analog-to-digital converter Which of the following is NOT a function of a PACS system? A)-Reconstruction of the image from the raw data B)-Long term data storage C)-digital distribution of images D)-image display for the radiologist - Correct Answer ️️ -A)-Reconstruction of the image from the raw data Which is NOT part of the CT Tube? a)-tungsten target B)-collimator C)-rotating anode D)-filament - Correct Answer ️️ -B)-collimator Which of the following is FALSE regarding CT systems? A)-they are limited to non-oblique transverse scanning B)-they cannot generate a straight coronal or Sagittal image C)-they have no moving parts? - Correct Answer ️️ -All of the answers are false X-rays are used in CT because: A) they are easily produced by the high frequency generator B)-they are less harmful than the heating effects of microwave radiation C)-they penetrate the body according to specific attenuation characteristics D)-The FDA imposes no limit on the dose to the patient - Correct Answer ️️ -C)-they penetrate the body according to specific attenuation characteristics of each tissue Most of the commands from the technologist are received by the: A)-Array processor B)-operators console C)-host computer D)-amplifier - Correct Answer ️️ -B)-Operators console X-Rays are produced whenever fast-moving electrons collide with any form of matter because: A)-the electron splits into two X-ray photons of equal energy upon impact with matter B)-the electron loses kinetic energy which is converted into the emission of an X-ray photon C)-the electron converts the electron it collides with into an X-ray photon - Correct Answer ️️ -B) the electron loses kinetic energy which is converted into the emission of an X-ray photon The mA determines: A)-quantity of X-ray photons B)-coefficient of attenuation C) slice thickness D)-energy level of the X-ray photons - Correct Answer ️️ -A)-Quantity of X-ray photons Which of the following is a component NOT normally located in the gantry of a modern CT system? A)-pre-patient collimator's B)-solid-state detectors C)-array processor D)-x-Ray tube - Correct Answer ️️ -C)-Array processor Tube inter scan delay time refers to: A)-the time between the end of once scan and the start of the next scan durning which the tube will cool B)-a quality assurance test performed daily by the technologist C)-the time required for the tube to make a complete 360 revolution about the gantry D)-the length of time required for the production of photons to begin after applying the voltage to the tube - Correct Answer ️️ -A)-the time between the end of one scan and the start of the next scan during which the tube will cool Increased ____________ will increase the likelihood t

Meer zien Lees minder
Instelling
CT Registry
Vak
CT Registry









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
CT Registry
Vak
CT Registry

Documentinformatie

Geüpload op
23 april 2024
Aantal pagina's
11
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€10,96
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
EmilyCharlene Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
445
Lid sinds
2 jaar
Aantal volgers
138
Documenten
21009
Laatst verkocht
15 uur geleden
Charlene\'s Scholastic Emporium.

Your Actual and Virtual Exam Tests Excellent Tutor.

3,7

98 beoordelingen

5
46
4
13
3
15
2
7
1
17

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen