EPA 608 study material including (Core, type 1, 2 and 3) with 100% correct answers
be connected as far away from the pump as possible a high capacity vacuum pump and short, large diameter hoses will dramatically reduce emissions, pressure drop, and evacuation/dehydration time ozone contains three oxygen atoms one chlorine atom can destroy 100,000 ozone molecules CFC's do not dissolve in water and do not breakdown into other compounds that dissolve in water CFC's cannot be washed out of the lower atmosphere ODP ozone depletion potential azeotrope where the mixture behaves like a single chemical (new refrigerant) HFC's will not damage the ozone in the stratosphere ... in 1992 the united states ordered the stoppage of all CFC production and importation after December 31, 1995 according to the clean air act, no person installing, maintaining, repairing, or disposing of any appliance may knowingly vent or otherwise release into the environment and class 1 or class 2 substance after July 1, 1992 class 1 CFC class 2 HCFC it became illegal to vent substitutes for CFC and HCFC refridgerants on November 15, 1995 any device which contains and uses a class 1 or class 2 substance as a refridgerant and is used for household or commercial purpose. appliance self contained recovery equipment type Active system dependent recovery equipment type Passive only section 609 certified technicians may buy CFC-12 in containers smaller than 20 pounds ... who must ensure that all refridgerant has been recovered prior to disposal of any appliance The final person in the disposal chain (scrap metal recycler, landfill owner, ect.) the removal of refridgerant in any condition Recovery to clean refridgerant by oil seperation, non-condensable removal and single or multiple passes through replaceable filter-driers to reduce moisture, acidity and particulate matter Recycling a complicated distillation process that returns recovered refridgerant to the purity of factory fresh refridgerant. Reclaiming (ARI Standard 700) under no circumstance should different refridgerants be mixed together Currently there is NOT a drop-in for CFC-12 ... oils that are hygroscopic Ester based (polyolesters) the alkylbenzene, use for some ternary blends ... as a general rule, different lubricants should never be mixed ... oxygen and oil when mixed can form an extremely explosive mixture sight glasses can be cleaned with alcohol spray before discarding a container the internal cylinder pressure should be reduced to at least 0 psig recovery cylinders must be approved by Department of Transportation (DOT) Refridgerant cylinders should never be filled above 80% capacity refridgerant cylinders should always be stored vertical or upright position with their valves at the top Service oses must be fitted with some type of low loss fitting to prevent the loss of refridgerant for small appliances, this service port typically is a straight piece of tubing that is entered using a Piercing access valve repair of leaks in small appliances is not required but should be repaired whenever possible MVAC systems are not classified as a type 1 appliance ... The EPA requires the certification of all technicians who service Type 1 air conditioning and refridgeration to comply with future changes in the law ...
Geschreven voor
- Instelling
- EPA 608
- Vak
- EPA 608
Documentinformatie
- Geüpload op
- 16 april 2024
- Aantal pagina's
- 8
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
epa 608 study material including core type 1 2
Ook beschikbaar in voordeelbundel