The bubbles formed in a positive multiple tube fermentation test are - ANSWER-Carbon Dioxide The maximum rate of withdrawal of gas from a 150lb chlorine cylinder in 24-hours is - ANSWER-40 lbs If you encounter a liquid chlorine leak in a one tone container, what action should you take first, to reduce the severity of the leak? - ANSWER-Rotate the container to place the leak at the top The most commonly used water disinfectant in the United States is - ANSWER-Chlorine When collecting a distribution system sample, the water should be allowed to run for a period of time prior to sample collection. How long - ANSWER-As long as necessary to permit cleaning of service line Sample bottles wich are furnished by a certified laboratory for collection of bacteriological samples - ANSWER-Are ready to use The difference between water pressure upstream and downstream of a pump when it is not in operations is know as the - ANSWER-Total static head A device that automatically shuts off flow in an elevated storage tank when the water level in the tank reache a preset level is termed a - ANSWER-Altitude valve In an occupied trench requiring personal egress what is the maximum allowable distance between a worker and an exit letter - ANSWER-25 feet A water bearing formation in the soil is referred to as - ANSWER-An aquifer The distance between the static water level and the pumping water level is termed the - ANSWER-Drawdown To prevent the entry of surface contamination into a well is the purpose of - ANSWER-Sanitary seal The presence of coliform bacteria in a distribution system - ANSWER-Indicates that pathogenic organisms may be present also The most common valve type in water distribution system is the - ANSWER-Gate valve A Venturi is a device used to - ANSWER-Measure water flow Backspin is occurring after well shut down this indicates - ANSWER-A faulty check valve

Meer zien Lees minder
Instelling
Water Distribution D1 /D2
Vak
Water distribution D1 /D2








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Water distribution D1 /D2
Vak
Water distribution D1 /D2

Documentinformatie

Geüpload op
8 april 2024
Aantal pagina's
4
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Water distribution practice test D1 /D2
Questions and Answers 100% Verified



The only absolutely reliable method of backflow prevention is the use of - ANSWER-
Air Gap

The bubbles formed in a positive multiple tube fermentation test are - ANSWER-
Carbon Dioxide

The maximum rate of withdrawal of gas from a 150lb chlorine cylinder in 24-hours is
- ANSWER-40 lbs

If you encounter a liquid chlorine leak in a one tone container, what action should
you take first, to reduce the severity of the leak? - ANSWER-Rotate the container to
place the leak at the top

The most commonly used water disinfectant in the United States is - ANSWER-
Chlorine

When collecting a distribution system sample, the water should be allowed to run for
a period of time prior to sample collection. How long - ANSWER-As long as
necessary to permit cleaning of service line

Sample bottles wich are furnished by a certified laboratory for collection of
bacteriological samples - ANSWER-Are ready to use

The difference between water pressure upstream and downstream of a pump when
it is not in operations is know as the - ANSWER-Total static head

A device that automatically shuts off flow in an elevated storage tank when the water
level in the tank reache a preset level is termed a - ANSWER-Altitude valve

In an occupied trench requiring personal egress what is the maximum allowable
distance between a worker and an exit letter - ANSWER-25 feet

A water bearing formation in the soil is referred to as - ANSWER-An aquifer

The distance between the static water level and the pumping water level is termed
the - ANSWER-Drawdown

To prevent the entry of surface contamination into a well is the purpose of -
ANSWER-Sanitary seal
€8,91
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
IMORA West Virginia University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
192
Lid sinds
2 jaar
Aantal volgers
77
Documenten
5079
Laatst verkocht
1 week geleden

4,4

69 beoordelingen

5
49
4
8
3
8
2
1
1
3

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen