100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

MICHIGAN RESIDENTIAL CODE practice exam with 100% correct answers already graded A+.

Beoordeling
-
Verkocht
-
Pagina's
30
Cijfer
A+
Geüpload op
29-03-2024
Geschreven in
2023/2024

Once work begins and for some reason work stops, you must start work again within ______ days or the permit is void. 30 60 90 180 180 Basic wind speeds for 50 year mean recurrence interval for Michigan is 60 miles per hour 70 miles per hour 80 miles per hour 115 miles per hour 115 miles per hour Ground snow loads for Michigan range from ______ in the southeast corner to _____ at the northern tip. 10 to 70 pounds per square foot 20 to 60 pounds per square foot 20 to 100 pounds per square foot 40 to 80 pounds per square foot 20 to 100 pounds per square foot Indicate the uniformly distributed live load for exterior balconies 40 pounds 60 pounds 80 pounds 100 pounds 40 pounds Indicate the uniformly distributed live load for decks attached to exterior walls 40 pounds 60 pounds 80 pounds 100 pounds 40 pounds Indicate the uniformly distributed live load for attics with storage 10 pounds 20 pounds 30 pounds 40 pounds 20 pounds Indicate the uniformly distributed live load for sleeping rooms 10 pounds 20 pounds 30 pounds 40 pounds 30 pounds Indicate the uniformly distributed live load for rooms other than sleeping rooms 10 pounds 20 pounds 30 pounds 40 pounds 40 pounds The minimum requirement for a door leading from the attached garage into the dwelling unit is 1 3/8" solid core Self closing wood door 1 3/4" wood door 1 3/4" solid core 1 3/8" solid core If a steel door is used for leading from the attached garage into the dwelling unit, the minimum fire rating would 20 minutes 1 hour 1 1/2 hour 2 hours 20 minutes An attached garage shall be separated from the dwelling unit by a minimum of _______ drywall applied to the garage wall side. 3/8 " 1/2 " 5/8 " 2 layers 1/2" 1/2 " An attached garage shall be separated from the living space above by a minimum of _______ drywall applied to the garage ceiling side. 3/8 " 1/2 " 5/8 " 2 layers 1/2" 5/8 " In reference to fire blocking, the maximum horizontal distance is ________ feet. 4 8 10 12 10 According to code, fireblocking is required At 8' intervals behind drywall. Between studs within the walls. At ceiling level. Anywhere flames could spread. At ceiling level. Draft stops shall be installed so that the area of any concealed space does not exceed 700 square feet 1000 square feet 1500 square feet 1800 square feet 1000 square feet Combustible insulation shall be separated a minimum of ________ inches from heat producing devices. 2 3 4 6 3 All habitable rooms shall be provided with aggregate glazing area of not less than ______ of the floor area. 4% 6% 8% 10% 8% The minimum openable area to the outdoors shall be ______ of the floor area being ventilated. 4% 6% 8% 10% 4% Every dwelling unit shall have at least one habitable room not less than _________ of gross floor area. 80 S.F. 100 S.F. 70 S.F. 200 S.F. 70 S.F. Every family room shall have not less than __________ square feet of gross floor area. 50 70 90 100 70 A living room , bedroom, or family room, shall not be less than ___________ in any horizontal direction. 5 feet 7 feet 10 feet 12 feet 7 feet A builder is installing replacement windows that do NOT contain safety glazing. If the bottom edge is less than 10 inches above the floor, what is the maximum permissible size of a single pain in these replacement windows according to code limits? 6 square feet. 9 square feet. 12 square feet. Not Premitted Not Premitted The net clear opening of a grade floor bedroom emergency escape window can be no less than ______. 5 square feet 5.7 square feet 7 square feet 8.5 square feet 5 square feet A bedroom emergency escape window shall have a clear net opening width of 16 inches 20 inches 24 inches 32 inches 20 inches

Meer zien Lees minder
Instelling
Michigan Residential Builders
Vak
Michigan residential builders










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Michigan residential builders
Vak
Michigan residential builders

Documentinformatie

Geüpload op
29 maart 2024
Aantal pagina's
30
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€14,50
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
BRAINBOOSTERS Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
654
Lid sinds
2 jaar
Aantal volgers
250
Documenten
22617
Laatst verkocht
2 dagen geleden

In this page you will find all documents , flashcards and package deals offered by seller BRAINBOOSTERS

4,5

339 beoordelingen

5
264
4
30
3
21
2
5
1
19

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen