100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

NICET Level 1 ITM of Water-Based Systems (A+ Guaranteed) 2024 Update

Beoordeling
-
Verkocht
-
Pagina's
7
Cijfer
A+
Geüpload op
10-02-2024
Geschreven in
2023/2024

NICET Level 1 ITM of Water-Based Systems (A+ Guaranteed) 2024 Update NICET Level 1 ITM of Water-Based Systems (A+ Guaranteed) 2024 Update Who is responsible for the inspection, testing, maintenance and impairment of a water based fire protection system? correct answers The Property owner or designated representative Who's responsibility is it to provide accessibility to components of a water based fire protection system? correct answers The property owner or designated representative Who shall correct or repair deficiencies or impairments found during the inspection, test and maintenance required by standard? correct answers The property owner or designated representative Who is qualified to preform the corrections and repairs of a water based fire protection system? correct answers Qualified maintenance personal or a qualified contractor A permanently marked metal or rigid plastic information sign shall be placed at the system control riser supplying an antifreeze loop, dry system, preaction, or auxiliary system control valve? correct answers An Information Sign, Records made during all inspections, tests and maintenance shall be made available to who upon request? correct answers The Authority Having Jurisdiction All records shall be maintained by? correct answers The Property Owner How long should subsequent records be retained? correct answers 1 year, After the testing and reinstallation of plugs and caps for auxiliary drain and test valves, what action is required? correct answers Shall be restored to full operational condition, To avoid false alarms where a supervisory service is provided the alarm receiving facility shall be notified by the property owner or designated representative before? correct answers conducting any test or procedure that could result in the activation of an alarm, Sprinklers shall be inspected when and how? correct answers Shall be inspected from the floor level annually Sprinklers shall not show signs of the following? correct answers leakage; shall be free of corrosion, foreign materials, paint, and physical damage; and shall be installed in the correct orientation Sprinklers installed installed in concealed spaces such as above ceilings shall what? correct answers Shall not require inspection, Sprinklers installed in areas that are inaccessible for safety considerations due to process operations shall be inspected? correct answers During each scheduled shutdown The supply of spare sprinklers shall be inspected when? correct answers Annually, A spare sprinkler wrench shall be required for what? correct answers Every type of sprinkler, Sprinkler pipe and fittings shall be inspected from where and when? correct answers Annually from from the floor level, Sprinkler Pipe hangers and seismic bracing shall be inspected? correct answers Annually from the floor level Gauges on a wet pipe sprinkler system shall be inspected? correct answers Monthly, Gauges on a dry, preaction system, and deluge systems shall be inspected? correct answers Monthly When the gauge near the compressor is reading higher than the gauge near the dry pipe valve, the air line shall be what? correct answers Taken out of service Waterflow alarm and supervisory alarm devices shall be inspected? correct answers Quarterly The hydraulic design information sign for hydraulically designed systems shall be inspected? correct answers Quarterly The information sign shall be inspected? correct answers Annually, Where sprinklers have been on service for 50 years shall be? correct answers Replaced Sprinklers manufactured prior to 1920 shall be? correct answers Replaced Sprinklers manufactured using fast-response elements that have been in service for 20 years shall be? correct answers Replaced or tested at 10 year intervals Representative samples of solder-type sprinklers with a temperature classification of extra high (325*F) or greater that are exposed to semi continuous to continuous maximum allowable ambient temperature conditions shall be? correct answers Tested at 5 year intervals Dry sprinklers that have been in service for 10 years shall be? correct answers Tested Where sprinklers are subjected to harsh environments, including corrosive atmospheres and corrosive water supplies, on a five years basis shall be? correct answers replaced or representative sprinkler samples shall be tested, Gauges shall be replaced every? correct answers 5 years

Meer zien Lees minder
Instelling
NICET Level 1 ITM Of Water-Based Systems (A+ Guara
Vak
NICET Level 1 ITM of Water-Based Systems (A+ Guara









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
NICET Level 1 ITM of Water-Based Systems (A+ Guara
Vak
NICET Level 1 ITM of Water-Based Systems (A+ Guara

Documentinformatie

Geüpload op
10 februari 2024
Aantal pagina's
7
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
PAUL692 Rasmussen College
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
276
Lid sinds
3 jaar
Aantal volgers
124
Documenten
709
Laatst verkocht
8 maanden geleden

4,2

33 beoordelingen

5
18
4
7
3
4
2
3
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen