100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Scriptie

Dissertation 2023- PMI Estimation: Conductivity

Beoordeling
-
Verkocht
-
Pagina's
22
Cijfer
A
Geüpload op
16-11-2023
Geschreven in
2022/2023

This is my dissertation from last year for Forensic Science and Molecular Biology MSci. I got the grade of 69%. The main focus of the experiment in the dissertation was to discover if electrical conductivity of a pig pancreas can be used to estimate time of death over a 2 week period. This document has statistical analysis and an in-depth literature review of other studies. It was a very interesting topic to study and had never been done before (or at least not been documented) on pig tissue! The other studies used rats and fish, as you'll see in the literature review. There are also quite a few images of the experiment process and the pig pancreas as it decomposed (was so smelly i had to wear a face mask AND vicks vapo rub under my nose towards the end). This document also contains a critical analysis of other PMI estimation methods. Although my grade wasn't the top of the top, it is still an interesting topic and there are lots of helpful references listed at the end relevant to PMI. Enjoy :)

Meer zien Lees minder
Instelling
Vak










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Studie
Onbekend
Vak
Onbekend

Documentinformatie

Geüpload op
16 november 2023
Aantal pagina's
22
Geschreven in
2022/2023
Type
Scriptie
Begeleider(s)
Peter cross
Jaar
Onbekend

Onderwerpen

Voorbeeld van de inhoud

Organ Conductivity Used as
a Post-Mortem Interval
Indicator- Porcine Pancreas
By


Sophie Millar




A Dissertation
Submitted to the School of Natural Sciences
University of Central Lancashire
In Partial Fulfilment of the Requirements for the Degree of
Master of Science in Forensic Science and Molecular Biology




18/04/2023
Supervised by: Peter Cross




1

,1. Abstract
Conductivity in correlation to post-mortem-interval (PMI) estimation was an idea originating
from meat science, in which the quality of meat is assessed in relation to conductivity
readings. This can potentially be applied to human medicolegal cases in which time-since-
death must be determined. This study, mainly on the porcine pancreas, found that there is a
positive correlation between conductivity and how many days passed since slaughter when
kept at ambient temperature. After statistical analysis, it was also determined that lower
Y −1203
temperatures resulted in an increase of conductivity readings. The equation X= was
339.21
calculated from the trendline on the graph in Figure 4, which can approximate days-since-
death to a value of +/-64.32 hours. Conductivity and temperature measurements of the
pancreatic tissue were taken every 24 hours over a period of 14 days using a Jenway
conductivity reader after using a Precellys Evolution homogeniser. Although decomposition
rate varies and has many factors affecting it, this study explored these variables and it may be
used in conjunction with other PMI estimation methods to achieve a more accurate time-
since-death, and potentially aiding in solving future medicolegal cases involving the death of
an individual.


Keywords: Post-Mortem-Interval, conductivity, pancreas, homogenisation,
decomposition, temperature.


Acknowledgements
I would like to thank my cohort Aaron Anderson, Luke Fitzgerald, James Guest, Anais
Mitchell and Melissa Wynn, as well as Steven Gough-Kelly and my supervisor Peter Cross
for their contribution to this study.


2. Introduction
2.1 Background Information
Determination of time-since-death is an important aspect of a medicolegal death
investigation, as it can ultimately aid in determining the circumstances and cause of death.
Post-mortem interval is currently estimated using observable markers such as Total Body
Score (TBS)(Megyesi et al., 2005) and biochemical markers such as vitreous humour analysis
(Madea, 2007) in which the vitreous humour potassium volumes in the eye is monitored as
the post-mortem period progresses. A widely accepted and utilised PMI indicator is algor
mortis monitoring. This is the process where the body begins to cool to ambient temperature
immediately after death due to cessation of body heat production, mainly by metabolism
(Eden, 2022). The Henssge nomogram, pictured in Figure 1, can be used in medicolegal
investigations to approximate time since death from the temperature of the corpse, preferably
taken rectally using a thermometer to obtain core temperature (Henssge and Madea, 2004).

2

, Figure 1, Henssge Nomogram-Algor Mortis
These methods, however, are subjected to error due to varying external and internal factors
during the decomposition process, such as ambient temperature and cause of death (Kil,
2019).
Although conductivity is a relatively new proposal in PMI estimation, it has been used
extensively in the meat industry to check for quality of meats. After a period of time post-
slaughter, meat tenderness deteriorates due to decomposition of the tissue. When readings are
taken, meats with higher conductivity readings are of a lower quality than fresh meats from
an animal immediately post-slaughter, which produces a better quality of meat with lower
conductivity readings. The theory behind this may be applied to human cases, where as the
flesh starts to decompose, the conductivity may increase (Czyżak‐Runowska, 2010).
As the post-mortem period progresses, the selective membrane permeability of the cell is lost
(Kamiura et al., 2019), resulting in any substance being able to diffuse through. This process

3
€5,31
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
sophieglenesslin

Maak kennis met de verkoper

Seller avatar
sophieglenesslin University of Central Lancashire Preston
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
0
Lid sinds
2 jaar
Aantal volgers
0
Documenten
6
Laatst verkocht
-

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen