The service specific item that contains a checklist of areas/systems to inspect is: - The fire prevention/protection record The minimum temp that must be maintained in order to use a wet pipe sprinkler system is - 40 F Class lll standpipe systems have a? - combination of a single 1 1/2 hose and a single 2 1/2 connection The extinguishing agent most effective on a fire involving animal or vegetable oils is: - wet chemical the type of alarm system most likely to result in a direct dispatch of fire personnel to a fire scene is: - a remote supervisory station alarm The detector that signals the presence of smoke when a beam of light is refracted is: - photoelectric light-scattering the kind of smoke detector that uses a pump to draw air samples into a high-humidity chamber is a - cloud chamber air sampling detector use a portable fire extinguisher with a rating of 4-A, 20 B:C on: - ordinary combustibles, flammable liquids, and energized electrical equipment you can tell the type of metals for which a class D portable fire extinguisher is approved by: - looking at the metals listed on the face plate Door and windows allowed in a fire wall are referred to as - protected openings before the occupant load for a building can be calculated, you must know the: - square footage and use of the building in determining the means of egress, an occupant load of less that 200 persons requires a minimum of _______ exits - 2 the clearance between a newly installed handrail and a wall cannot be less that - 2 1/4in The means of egress must be illuminated at a minimum of ________ foot-candles - one when more that one exit is needed in an unsprinklered room or building, exits should be separated by at least one half the ________ distance of the room - diagonal in a cooking exhaust system, the filter will be found in the - type l hood cooking equipment must be kept away from combustible material by a distance of at least - 18 in the maximum number of storage cabinets allowable in a spray area is: - three structural sections of a spray area can be sealed with: - latex-based caulk two ways you may be able to determine weather a decorative material meets NFPA requirements; - - performing a field flammability test -reading the label interior floor finishes are grouped into classes determined by the: - critical radiant flux ratings on a sprinkler system, the clapper valve is found in the: - alarm valve the purpose of a dry pipe valve is to: - keep water out of the sprinkler system until a fire activates a sprinkler three important things to check or validate during a visual inspection of a fire extinguisher - -check the inspection tag -ensure the pin and seal are in place -look for signs of visible physical damage when inspecting the distribution main in a sprinkler system, pay careful attention to all components because the distribution main is the pipe that: - provides the water supply for the system the person normally assigned to make the head count at an exit drill gathering area is the: - evacuation monitor The best way to test fire evacuation plans is to conduct - regular fire exit drills water distribution systems are made up of a primary feeders(mains) secondary feeders, and: - distributors to compute hydrant flow, you must know the coefficient of discharge ( based upon the shape of the hydrant outlet), the diameter of the hydrant, and: - the pressure read at the hydrant orifice the main reason to develop an outline before you start to wrote your document is so you can later - organize your thoughts during an inspection, you walk inside a building where automobiles are stores. such storage indicates the need for: - A permit or written approval How should a fire inspector handle customer complaints - ensure that each complaint is documented. DoD agencies are directed to adopt policies for records management and disposition by - DoDD 5015.2 a true statement about work request approvals - they are required to make modifications to the building three ways a fire inspector should prepare for an inspection - -contact the building manager to arrange a time for the inspection -review the facility folder for the building to be inspected -use the reference library to research the codes and standards that apply to the facility three ways to achieve fire prevention " buy in" in the community - -conduct fire prevention demonstrations -create positive impressions -exchange info with other agencies before you begin planning a meeting:` - make sure that a meeting is the best way to accomplish your objectives FM-200 is a - Clean agent On an initiating device, the design requirement that prevents light flame detectors from alerting too easily is the - flickering action unlike fire walls, fire portions extend from - one floor to the underside of the floor above the minimum corridor width is determined by the: - number of people and the type of occupancy a sign with letters required to be not less than 6 in high and at least 2 in wide is: - an externally illuminated EXIT sign When inspecting HVAC systems, check the ducts for: - smoke detectors In automatic spray systems, the spray apparatus cannot function unless another type of apparatus is operating, This apparatus is? - an exhaust fan
Geschreven voor
- Instelling
- Inspector 1
- Vak
- Inspector 1
Documentinformatie
- Geüpload op
- 11 oktober 2023
- Aantal pagina's
- 8
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
inspector 1 quiz
-
inspector 1
Ook beschikbaar in voordeelbundel