100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

NATE HEAT PUMP QUESTIONS WITH COMPLETE VERIFIED ANSWERS

Beoordeling
-
Verkocht
-
Pagina's
10
Cijfer
A+
Geüpload op
19-06-2023
Geschreven in
2022/2023

NATE HEAT PUMP QUESTIONS WITH COMPLETE VERIFIED ANSWERS R-22 vapor line diameters and lengths are typically specified for a vapor pressure drop that does not exceed - ANSWER-6-7 psi or 6 degrees F The primary purpose of using flux when soldering copper or brass parts is to prevent - ANSWER-Oxidation The water that results from a defrost cycle of an air to air heat pump (runoff) must drain off and away from the outdoor coil to prevent - ANSWER-Excessive ice build up The component used to reduce sound transmission and prevent water leaks of a packaged heat pump installed on a roof is the - ANSWER-Curb gasket When under a deep vacuum, a hermetic refrigeration compressor's motor windings could be ________ if energized - ANSWER-Damaged In order for an evacuation to be considered complete, a heat pump refrigerant circuit should be evacuated to a vacuum pressure of - ANSWER-500 microns or below A system is supplied from the factory with charge for a 15-foot line set. The data plate shows the required system charge to be 5 pounds 10 ounces. The line set uses a 3/8-inch liquid line and is 25 feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigerant to be added for each added foot of refrigerant line length so the total refrigerant charge for the system would be - ANSWER-6 lbs(25-15=10 10x0.6=6oz 6oz+5lbs 10oz= 5lbs 16oz the equivalent of 6lbs) Drive slips are typically installed on the __________ sides of rectangular ducts - ANSWER-Shorter To properly set a heat anticipator it is necessary to check the - ANSWER-heating control circuit amperage draw A heat pump operating in normal ice free conditions maintains a certain temperature difference between the outdoor coil temperature and the surrounding outdoor ambient. This temperature difference is referred to as - ANSWER-Coil TD (temperature difference) The smallest refrigerant leak that an electronic leak detector should be capable of sensing is - ANSWER-0.05 oz. per year When checking the pressures in an operating system with a manifold gauge set, refrigerant oil in a hose will have ___ ______ on the gauge reading - ANSWER-No effect At sea level, a gauge pressure of 35 psig is equal to an absolute pressure of - ANSWER-49.7 psia A technician measures the return air temperature of a 100,000 Btu output furnace to be 65°F and the supply side air temperature is 135°F. The CFM would be - ANSWER-1323 (TD= 135-65=70️100,000/TDx1.08 ️100,000/75.6=1323) A residential supply diffuser that is noisy because of a loose vane is best serviced by - ANSWER-Replacing the diffuser When performing preventive maintenance on a heat pump the technician should check the outdoor fan to be certain that the fan - ANSWER-runs freely with no binding What is the effect of 170 volts supplied to a 208/230 volt compressor would cause a current - ANSWER-increase and the motor may trip on overload On a service call for a cooling problem with a heat pump, your inspections find a liquid line that has condensation on it. The most likely cause would be the - ANSWER-liquid line is restricted A reason for cool air complaints when a heat pump is operating in the heating cycle is - ANSWER-excessive supply air velocities A dirty or clogged air filter in an operating heat pump system can cause - ANSWER-inadequate heating To minimize noise problems in residential duct systems, the range (recommended to maximum) of design air velocity in the rectangular main supply trunk is - ANSWER-700 to 900 fpm The effect of adding a charge to sub cooling is - ANSWER-it increases it

Meer zien Lees minder
Instelling
Nate Heat Pump Service
Vak
Nate heat pump service









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Nate heat pump service
Vak
Nate heat pump service

Documentinformatie

Geüpload op
19 juni 2023
Aantal pagina's
10
Geschreven in
2022/2023
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€12,30
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
swabra
5,0
(1)

Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
swabra NURSING
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
4
Lid sinds
2 jaar
Aantal volgers
4
Documenten
209
Laatst verkocht
1 jaar geleden

5,0

1 beoordelingen

5
1
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen