Glossary of Electric Station Operator Terms

1. ACCIDENT PREVENTION TAGS (APTs): Temporary signs or tags that have preprinted instructions and markings used

to:

*Restrict operation or other action so that personnel and or systems and components are protected

*Warn that the tagged system or component is in a condition for test or maintenance activities

*Indicate that the system or component is under the operating jurisdiction of an organizational unit other than the operating agent.

2. AIR CIRCUIT BREAKER: A circuit breaker in which the interruption occurs in air.


3. ALTERNATING CURRENT: That form of electric current that changes in magnitude and polarity in what

is normally a regular pattern for a given time period.

4. AMMETER: An instrument for measuring electric current.


5. AMPERE: The unit of current flow of electricity. One ampere is equal to one coulomb per second flow.


6. APPARENT POWER: For single phase, the current in amperes times the electromotive force in volts equals

the apparent power in volt-amperes. This term is used for alternating current circuits because the current flow is not always in phase with

the electromotive force; hence, amperes times volts does not necessarily give the true power. Apparent power for three-phase circuits

equals volts times amperes times 1.73.

7. AUTHORIZED PERSON: A person that is authorized to receive Work Authorities on circuits and equip-

ment from the Load Dispatcher or their Field Representatives. Certification as an Authorized Person is required in order to hold any form of

Work Authority.

8. AUTOMATIC RECLOSER (ARs): An AR (Auto Recloser) is a reclosing device (relay), or a function of an

IED, that initiates the reclosing of a circuit after it has been opened by a protective relay.




,9. AUTOTRANSFORMER: A transformer in which the primary and secondary have a common winding.


10. AUTOMATIC RECLOSING: A circuit breaker feature that will cause the CB to reclose automatically after

it has relayed.

11. AUTOMATIC TRANSFER SWITCH (ATS): An ATS is a device used to automatically transfer con-nections from

one circuit to another, commonly used for transferring a station service load from a preferred source to an alternate source.

12. BANK: One or more transformers that furnish three-phase power to a load.


13. BANK OF TRANSFORMERS: Any group of transformers connected together with some point on each

winding held in common. It may be for the purpose of voltage transformation or circuit isolation.

14. BARRICADE: A physical obstruction placed to warn against accidental contact with a hazard or restrict entry into a

hazard area. Barricades may be plastic Barricade tape of any color, flags, or any other device that will serve this purpose.

15. BATTERY: A group of several cells connected together as a unit for furnishing electric current.


16. BELT CIRCUITS: Overhead or underground circuits connecting receiving and switching stations together

and through which power can flow in either direction.

17. BID: A request to program complex or supplemental work...usually in advance...on Power System equipment, that

requires a Clearance or OK TO.

18. BLADE: The hinged or moving part of a disconnect through which current flows.


19. BLOCK DIAGRAM: A symbolic diagram; a diagram depicting the distributing stations supplied by a

receiving station as rectangles and all lines or cables connecting them as solid or dashed lines respectively; and usually referred to as a

34.5kV System block diagram.

20. BREAKER: See CIRCUIT BREAKER.


21. BUS: A bus conductor, or group of conductors, which serves as a common connection for several circuits within




, a station or switchyard.

22. BUS TIE: The means by which two separate buses (Bus No. 1 and Bus No. 2) may be electrically connected together

through a set of disconnects and circuit breaker.

23. CABLE: 1. An electrical circuit that is entirely underground is designated as a Cable. 2. The underground portion of a

combination electrical circuit. 3. The type of conductor that is installed underground.

24. CAPACITANCE: The ability of a conductor to store an electric charge.


25. CAPACITIVE REACTANCE: The opposition offered by capacitance to the flow of current and which is

expressed in ohms.

26. CAPACITOR: A device that stores an electric charge; two electrodes or group of electrodes called plates and which are

separated by an insulator or dielectric.

27. CAPACITY: The number of amperes of electric current a conductor, switch, circuit breaker, disconnect, bank, etc., will

carry without becoming overly heated.

28. CB, AIR: A breaker in which the interruption takes place in air.


29. CB, AIR BLAST: A breaker in which the interruption of current is accomplished with a blast of compressed

air supplied from an air compressor system.

30. CB, GAS: A breaker in which the interruption takes place in a pressurized gas chamber, normally SF6.


31. CB, OIL: A breaker in which the interruption takes place in oil.


32. CB, VACUUM: A breaker in which the interruption takes place in a vacuum.


33. CELL: A compartment for enclosing circuit breakers or other electrical equipment; a single unit of a battery.


34. CIRCUIT: A conductor or that part of an electrical device designed to carry current.


35. CIRCUIT BREAKER (CB): A device for interrupting current flow in a circuit under normal or fault conditions.

Geschreven voor

Instelling
Glossary of Elems
Vak
Glossary of Elems

Documentinformatie

Geüpload op
25 april 2026
Aantal pagina's
16
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€14,39
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
HESIGRADER001 chamberlain college of nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
50
Lid sinds
4 jaar
Aantal volgers
41
Documenten
4075
Laatst verkocht
3 maanden geleden

2,6

8 beoordelingen

5
2
4
1
3
1
2
0
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen