100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

NHIE FINAL EXAM 2026 ACTUAL QUESTIONS AND ANSWERS GRADED

Beoordeling
-
Verkocht
-
Pagina's
10
Cijfer
A+
Geüpload op
25-01-2026
Geschreven in
2025/2026

NHIE FINAL EXAM 2026 ACTUAL QUESTIONS AND ANSWERS GRADED

Instelling
Nhie
Vak
Nhie









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Nhie
Vak
Nhie

Documentinformatie

Geüpload op
25 januari 2026
Aantal pagina's
10
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

NHIE FINAL EXAM 2026 ACTUAL QUESTIONS AND
ANSWERS GRADED A+
✔✔41. When inspecting the structural system, the inspector is required to
A. inspect only the visible components in the attic and crawl space.
B. specify method of structural repairs to the system.
C. report all structural deficiencies observed.
D. determine the cause and origin of the damage. - ✔✔C

✔✔42. A ground fault occurs when
A. too many devices are used on a circuit.
B. a hot conductor touches another hot conductor.
C. a hot conductor touches a grounded surface or grounding conductor.
D. a grounded conductor comes in contact with a grounding conductor. - ✔✔C

✔✔43 Electrical receptacles in bathrooms should be
A. GFCI protected.
B. at least 3 feet away from showers and bathtubs.
C. not more than 2 feet from the vanity basin.
D. waterproofed. - ✔✔A

✔✔44. Medium efficiency furnaces have a draft inducer fan and are connected directly
to the vent system instead of having a draft hood. There are white and yellowish
deposits below the draft inducer fan. A possible explanation for these deposits is that
A. the seal between the draft inducer fan and the furnace is failing.
B. moisture is condensing in the vent and running back into the draft inducer fan.
C. the draft inducer fan is not operating properly.
D. the furnace has failed and is unsafe to operate. - ✔✔B

✔✔45. The purpose of a trap in the waste drainage system is to
A. provide maintenance access.
B. prevent siphoning.
C. block sewer gases.
D. cause water to drain smoothly. - ✔✔C

✔✔46. A home inspection typically includes an examination of
A. adequacy of heat supply.
B. heat exchangers.
C. humidifiers.
D. vents, flues, and chimneys. - ✔✔D

✔✔47. In new construction, the MINIMUM overhead electrical serv ice clearances are
A. walkway: 8 feet, roadway: 16 feet, deck: 10 feet
B. walkway: 9 feet, roadway: 15 feet, deck: 12 feet

, C. walkway: 10 feet, roadway: 18 feet, deck: 10 feet
D. walkway: 12 feet, roadway: 20 feet, deck: 12 feet - ✔✔C

✔✔48. During a summertime inspection, what could indicate chronic condensation
problems in an attic?
A. The attic is very warm.
B. There is no vapor retarder on the insulation.
C. There are gray/black stains on the north side roof sheathing.
D. There are mildew stains on the bathroom ceilings. - ✔✔C

✔✔49. Ice damming at the eaves may be caused by
A. inadequate attic insulation.
B. undersized gutters.
C. shallow roof slope.
D. improper flashing. - ✔✔A

✔✔50. The purpose of fla shing on a roof is to
A. shed water onto roofing materials.
B. seal roof shingles to vertical surfaces.
C. protect roofing material.
D. join different roofing materials. - ✔✔A

✔✔51. The house you are inspecting currently has a gas-fired furnace or boiler. Each of
the following clues may indicate that the house also has an abandoned buried fuel oil
storage tank EXCEPT
A. small diameter copper tubes emerging from the inside of the foundation wall or the
floor
near the furnace or boiler
B. an approximately 1 % inch diameter vent pipe outside coming from underground up
against the foundation
C. the brick chimney serving the furnace or boiler has deteriorated mortar joints at the
bottom
D. your knowledge that the neighborhood h ad or still h as some houses served by oil
heat - ✔✔C

✔✔52. While inspecting a heat pump in the cooling mode, you measure a 28 degrees F
temperature differential between the interior supply and return air. You should su spect
A. an exterior fan running too slowly.
B. an overheating compressor.
C. a dirty filter.
D. a thermostat set too low. - ✔✔C

✔✔53. What is the MINIMUM electrical service drop clearance from a residential
driveway?
A. 12 feet

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
BOARDWALK Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
186
Lid sinds
1 jaar
Aantal volgers
7
Documenten
25069
Laatst verkocht
1 dag geleden
BOARDWALK ACADEMY

Ace Your Exams With Top Quality study Notes And Paper✅✅ ALL ACADEMIC MATERIALS AVAILABLE WITH US✅✅ LEAVE A REVIEW SO THAT WE CAN LOOK AND IMPROVE OUR MATERIALS.✅✅ WE ARE ALWAYS ONLINE AND AVAILABLE DONT HESITATE TO CONTACT US FOR SYUDY GUIDES!!✅✅ EVERYTHING IS GRADED A+✅✅ COLOUR YOUR GRADES WITH US , WE ARE HERE TO HELP YOU DONT BE RELACTANT TO REACH US

3,7

33 beoordelingen

5
14
4
6
3
7
2
0
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen