Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ALASKA

Beoordeling
-
Verkocht
-
Pagina's
8
Cijfer
A+
Geüpload op
18-01-2026
Geschreven in
2025/2026

Exam of 8 pages for the course ALASKA Mechanical Administrator Unlimited Com at ALASKA Mechanical Administrator Unlimited Com (ALASKA)

Instelling
ALASKA Mechanical Administrator Unlimited Com
Vak
ALASKA Mechanical Administrator Unlimited Com

Voorbeeld van de inhoud

ALASKA (AK) Mechanical Administrator Unlimited Commercial and Industrial
Plumbing Exam LATEST QUESTIONS AND CORRECT ANSWERS GRADE A



What is the minimum required size for the drain outlet for a commercial garbage disposal
unit with a 1-1/2 horsepower motor, according to the Uniform Plumbing Code (UPC)?

A) 1-1/2 inches

B) 2 inches

C) 3 inches

D) 4 inches

**Answer: B**

**Explanation:** UPC 802.2.1 requires a drain outlet of not less than 2 inches for
commercial food waste grinders with motors of 1 horsepower or greater.



When sizing the water heater for a commercial laundry facility, what is the primary factor
that must be determined first?

A) The floor area of the laundry room

B) The peak hourly demand in gallons of hot water at the required temperature

C) The voltage available at the service panel

D) The number of washing machines

**Answer: B**

**Explanation:** Sizing is based on the **peak hourly demand**, calculated using fixture
counts and demand factors from the UPC (or manufacturer specs for specific appliances),
not just the number of fixtures.



According to UPC requirements, what is the minimum slope for a 4-inch diameter
horizontal drain pipe installed inside a building?

A) 1/16 inch per foot

B) 1/8 inch per foot

, C) 1/4 inch per foot

D) 1/2 inch per foot

**Answer: B**

**Explanation:** UPC Table 704.1 specifies the minimum slope for a 4-inch diameter drain
pipe is **1/8 inch per foot (1%)**.



In a multi-story commercial building, what device must be installed to prevent excessive
static pressure on the lower floors in the domestic water supply system?

A) A check valve

B) A pressure-reducing valve (PRV)

C) An expansion tank

D) A vacuum breaker

**Answer: B**

**Explanation:** **Pressure-reducing valves (PRVs)** are required on individual floor
branches or zones where the static pressure from the height of the water column exceeds
80 psi (UPC 604.8) to prevent fixture damage and water hammer.



What is the minimum required number of water closets for a commercial office building
with 125 male employees and 125 female employees, according to the 2018 UPC?

A) 2 for men, 2 for women

B) 3 for men, 3 for women

C) 2 for men, 3 for women

D) 3 for men, 4 for women

**Answer: D**

**Explanation:** Using UPC Table 422.1: For 1-150 occupants, men require 1-3 water
closets (125 requires 3). Women require 1-4 water closets (125 requires 4). This is based on
the calculation for "Assembly" or "Office" occupancy.

Geschreven voor

Instelling
ALASKA Mechanical Administrator Unlimited Com
Vak
ALASKA Mechanical Administrator Unlimited Com

Documentinformatie

Geüpload op
18 januari 2026
Aantal pagina's
8
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€12,84
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
GerryBlair

Maak kennis met de verkoper

Seller avatar
GerryBlair University Of Texas - Arlington
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
2 maanden
Aantal volgers
0
Documenten
60
Laatst verkocht
1 week geleden

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen