100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

EPA SECTION 608 UNIVERSAL CERTIFICATION EXAM QUESTION AND CORRECT ANSWERS(VERIFIED ANSWERS) PLUS RATIONALES 2026 Q&A INSTANT DOWNLOAD PDF

Beoordeling
-
Verkocht
-
Pagina's
20
Cijfer
A+
Geüpload op
15-01-2026
Geschreven in
2025/2026

EPA SECTION 608 UNIVERSAL CERTIFICATION EXAM QUESTION AND CORRECT ANSWERS(VERIFIED ANSWERS) PLUS RATIONALES 2026 Q&A INSTANT DOWNLOAD PDF

Instelling
EPA SECTION 608 UNIVERSAL CERTIFICATION
Vak
EPA SECTION 608 UNIVERSAL CERTIFICATION










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
EPA SECTION 608 UNIVERSAL CERTIFICATION
Vak
EPA SECTION 608 UNIVERSAL CERTIFICATION

Documentinformatie

Geüpload op
15 januari 2026
Aantal pagina's
20
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

EPA SECTION 608 UNIVERSAL
CERTIFICATION EXAM QUESTION AND
CORRECT ANSWERS(VERIFIED
ANSWERS) PLUS RATIONALES 2026 Q&A
INSTANT DOWNLOAD PDF

1. Which refrigerant is classified as an ozone-depleting substance (ODS)?
A. R-134a
B. R-410A
C. R-22
D. R-404A
Rationale: R-22 is an HCFC that contributes to ozone depletion, unlike
HFCs such as R-134a and R-410A.
2. EPA Section 608 regulations apply to which of the following?
A. Motor vehicle air conditioning systems only
B. Appliances containing less than 5 lbs of refrigerant
C. Stationary refrigeration and air-conditioning equipment
D. Portable refrigerators only
Rationale: Section 608 covers stationary appliances, while motor vehicles
fall under Section 609.
3. What is the required recovery level for high-pressure appliances when
using certified recovery equipment manufactured after Nov 15, 1993?
A. 0 psig
B. 10 inches of Hg vacuum
C. 15 psig
D. Atmospheric pressure
Rationale: EPA requires recovery to 10 inches of mercury vacuum for high-
pressure appliances.

,4. Which refrigerant has the highest ozone depletion potential (ODP)?
A. R-134a
B. R-11
C. R-410A
D. R-404A
Rationale: CFC-11 has one of the highest ODP values and is heavily
regulated.
5. Which certification allows a technician to work on all types of appliances?
A. Type I
B. Type II
C. Type III
D. Universal
Rationale: Universal certification combines Types I, II, and III.
6. Type I certification is required to service which appliances?
A. High-pressure systems
B. Low-pressure chillers
C. Small appliances containing 5 lbs or less of refrigerant
D. Industrial refrigeration systems
Rationale: Type I specifically covers small, factory-sealed appliances.
7. Which refrigerant is commonly used in low-pressure chillers?
A. R-22
B. R-410A
C. R-123
D. R-404A
Rationale: R-123 is a low-pressure refrigerant used in centrifugal chillers.
8. What must be done before opening a refrigeration system for service?
A. Add refrigerant
B. Recover refrigerant
C. Vent refrigerant
D. Increase system pressure
Rationale: Venting refrigerant is illegal; recovery is required.
9. Which leak rate threshold requires repair for commercial refrigeration?
A. 10% per year

, B. 20% per year
C. 30% per year
D. 5% per year
Rationale: EPA requires repair when leaks exceed 20% annually for
commercial systems.
10.What instrument is used to detect refrigerant leaks electronically?
A. Manifold gauge
B. Thermometer
C. Electronic leak detector
D. Vacuum pump
Rationale: Electronic leak detectors sense refrigerant in the air.


11.Which refrigerant is an HFC with zero ODP?
A. R-22
B. R-11
C. R-134a
D. R-12
Rationale: HFCs like R-134a do not deplete the ozone layer.
12.Recovery equipment must be certified by which organization?
A. OSHA
B. ASHRAE
C. EPA
D. UL
Rationale: The EPA approves and certifies refrigerant recovery equipment.
13.What is the main purpose of evacuation?
A. Add oil
B. Remove moisture and non-condensables
C. Increase pressure
D. Test electrical components
Rationale: Evacuation prevents system damage and inefficiency.
14.Which refrigerant is considered a blend?
A. R-22
€27,01
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
mrpass

Maak kennis met de verkoper

Seller avatar
mrpass Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
Nieuw op Stuvia
Lid sinds
1 maand
Aantal volgers
0
Documenten
804
Laatst verkocht
-

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen