100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

PMT 108 WATER ACTUAL 2026 TEST PAPER QUESTIONS AND SOLUTIONS RATED A+

Beoordeling
-
Verkocht
-
Pagina's
13
Cijfer
A+
Geüpload op
04-01-2026
Geschreven in
2025/2026

PMT 108 WATER ACTUAL 2026 TEST PAPER QUESTIONS AND SOLUTIONS RATED A+

Instelling
PMT 108
Vak
PMT 108









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
PMT 108
Vak
PMT 108

Documentinformatie

Geüpload op
4 januari 2026
Aantal pagina's
13
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

PMT 108 WATER ACTUAL 2026 TEST PAPER QUESTIONS
AND SOLUTIONS RATED A+
✔✔Maximum Contaminant Levels - ✔✔MCL

✔✔Trihalomethanes (THM) - ✔✔Commonly found in chlorinated drinking water,
particularly in drinking water obtained from surface sources; formed by the reaction of
naturally occurring organic substances and chlorine during drinking water treatment and
distribution

✔✔Chlorination Methods - ✔✔Under normal conditions, most widely used

✔✔Batch chlorinating - ✔✔A calculated amount of HYPOCHLORITE is added to a
known volume of water

Care must be taken when using calcium hypochlorite to not allow granules to enter the
finished product

✔✔Hypochlorinators - ✔✔Mechanically deliver pre-measured amounts of chlorine gas,
ammonia, or hypochlorites automatically to a known flow rate of water

✔✔Marginal chlorinating - ✔✔Initial chlorine demand has been satisfied, but some
oxidizable substances remain

Refers to the application of chlorine to produce the desired total chlorine residual
without reference to the relative amounts of free or combined chlorine present

✔✔Super chlorination - ✔✔Application of chlorine in greater concentrations than are
needed to afford acceptable BACTERICIDAL efficiency

Gives control over taste and odor producing substances as well as control of bacteria

Surplus chlorine is removed by de-chlorinating with sulfur dioxide, aeration, or activated
carbon before the water enters the distribution system

✔✔Break-point chlorinating - ✔✔Chlorine is applied to produce a chlorine residual
composed of predominantly FAC with little or no combined chlorine

Advantages of chlorinating to and beyond the breakpoint to obtain FAC residuals are
that most odors and taste normal to water are destroyed and disinfection is assured

✔✔Chloramine disinfection - ✔✔Select the point of ammonia addition downstream of
the primary disinfection with free chlorine, chlorine dioxide, or ozone and minimize the
amount of free ammonia leaving the treatment plant and entering the distribution
systems

, Maintain an adequate chloramine residual within the distribution system taking into
consideration chloramines are weaker disinfectants than free chlorine

✔✔2 mg/L - ✔✔It is recommended to maintain a total chlorine residual of ___ mg/L.

✔✔Leak detection equipment
SCBA (Self Contained Breathing Apparatus)
Atmospheric monitoring devices - ✔✔Chlorine safety program: Periodic hands-on
training using the following safety equipment (3)

✔✔Potable water distribution reservoirs are necessary for: - ✔✔Firefighting
Satisfy peak demands
Support uniform water pressure
Meet industrial demands
Avoid continuous pumping
Provide emergency water reserve

✔✔NSF approved - ✔✔All tank coatings must be equivalent...

✔✔Six (6) inches above grade - ✔✔Sanitary standards for water storage: BELOW
ground level

The overflows (e.g., manhole covers and vents) must be located with their tops ___
inches above grade.

✔✔A minimum of eight (8) feet - ✔✔Sanitary standards for water storage: BELOW
ground level

The bottom of the tank must be higher than the water table or flood water; designed for
a minimum of ___ feet.

✔✔Higher - ✔✔Sanitary standards for water storage: BELOW ground level

The tanks must be located at a level that is ___ that any sewers or sewage systems.

✔✔At least 50 feet - ✔✔Sanitary standards for water storage: BELOW ground level

Sewers or sewage disposal systems must be located at least ___ feet from water
storage tanks.

✔✔Overflow and drain pipes - ✔✔Must not be directly connected to sewers

✔✔When potable water tanks are ABOVE ground level - ✔✔Ladders with approved
safety cages must be used on all standpipes and elevated storage tanks

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
BOARDWALK Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
179
Lid sinds
1 jaar
Aantal volgers
6
Documenten
24136
Laatst verkocht
1 dag geleden
BOARDWALK ACADEMY

Ace Your Exams With Top Quality study Notes And Paper✅✅ ALL ACADEMIC MATERIALS AVAILABLE WITH US✅✅ LEAVE A REVIEW SO THAT WE CAN LOOK AND IMPROVE OUR MATERIALS.✅✅ WE ARE ALWAYS ONLINE AND AVAILABLE DONT HESITATE TO CONTACT US FOR SYUDY GUIDES!!✅✅ EVERYTHING IS GRADED A+✅✅ COLOUR YOUR GRADES WITH US , WE ARE HERE TO HELP YOU DONT BE RELACTANT TO REACH US

3,7

33 beoordelingen

5
14
4
6
3
7
2
0
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen