100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Med gas Mock Exam Questions And Answers

Beoordeling
-
Verkocht
-
Pagina's
25
Cijfer
A+
Geüpload op
03-01-2026
Geschreven in
2025/2026

Med gas Mock Exam Questions And Answers WAGD networks shall provide a WAGD inlet in all locations where __________ is intended to be administered. a. Nitrogen b. Medical Air c. Nitrous Oxide d. Oxygen Audible and visual alarm indicators shall meet which of the following requirements? a. Individual indicators shall NOT be less than DN20 size b. Testing to determine indicator function should be scheduled periodically and records maintained between testing. c. CGA C-7 d. The staff should be trained to operate the test button periodically and report malfunctions. Only one service valve is required for each branch off the riser, unless the number of zone valves on that branch exceeds ______ valves. a. 6 b. 8 c. there is no maximum d. 4 Which of the following systems shall not be permitted to be located in an outdoor enclosure? a. Bulk cryogenic liquid systems b. Manifolds for gas cylinders c. Manifolds for cryogenic liquid containers d. Medical air compressor sources NFPA 99 requires tubing to be cut square using a sharp tubing cutter that shall be free from grease, oil or other lubricants not suitable for oxygen service. What sort of treatment is permitted of the tube ends before brazing? a. May be reamed b. May be deburred or rolled smooth c. May be re-cleaned d. none of the above Excluding outdoor locations, which of these is an NFPA 99 requirement for the wiring of each of the two mandatory master alarms? a.Common conductors b.Without any splices c.Wired independently to the initiating device(s) for each signal d.Alarms shall be sent to the area alarm panel in the emergency room Inspection and testing shall be performed on all new piped gas systems, additions, renovations, temporary installations or repaired systems to assure the facility that all applicable provisions of NFPA 99C have been adhered to and system integrity has been achieved or maintained. What is required of the individual doing the testing or inspecting? a.Have two years experience b.Have a documented procedure c.Be a certified tester of the above With the approval of the authority having jurisdiction, in what areas shall the shutoff valves be permitted to be secured to prevent inappropriate access? cal care iatric or pediatric nity hetizing For purposes of this code, an oxygen enriched atmosphere is an atmosphere where to total concentration of oxygen exceeds _______ by volume. a.23.5% b.23.6% c.19.5% d.93% Compressed gas cylinders must meet which of the following criteria in order to be acceptable for use in an acute health care facility? a.Be appropriately identified by labels or stencils in accordance with CGA C-7 criteria b.Be appropriately color coded in accordance with U.S.D.A. requirements c.Be constructed in accordance with specifications and regulations of OSHA d.Utilize gas specific CGA connections In those portions of the system intended to handle oxygen at pressures greater than 350 psi, the interconnecting hose shall not contain __________ materials. less steel eric r To facilitate service, testing or replacement, all pressure switches and mainline gauges downstream of the source valve shall be provided with a ________________. a.Check valve b.Shutoff valve c.Demand check fitting d.D.I.S.S. fitting Those sections or portions of the piping system that serve a room or group of rooms on the same story of the facility. This is the definition of which of the following? a.Main lines b.Risers c.Vent Lines d.Branch (lateral) lines

Meer zien Lees minder
Instelling
Med Gas Refresher
Vak
Med gas Refresher










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Med gas Refresher
Vak
Med gas Refresher

Documentinformatie

Geüpload op
3 januari 2026
Aantal pagina's
25
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Med gas Mock Exam Questions And Answers




WAGD networks shall provide a WAGD inlet in all locations where __________ is
intended to be administered.


a. Nitrogen
b. Medical Air
c. Nitrous Oxide
d. Oxygen



Audible and visual alarm indicators shall meet which of the following
requirements?


a. Individual indicators shall NOT be less than DN20 size
b. Testing to determine indicator function should be scheduled periodically and
records maintained between testing.
c. CGA C-7
d. The staff should be trained to operate the test button periodically and report
malfunctions.



Only one service valve is required for each branch off the riser, unless the
number of zone valves on that branch exceeds ______ valves.

a. 6
b. 8
c. there is no maximum
d. 4



Which of the following systems shall not be permitted to be located in an outdoor
enclosure?
a. Bulk cryogenic liquid systems

,b. Manifolds for gas cylinders
c. Manifolds for cryogenic liquid containers
d. Medical air compressor sources


NFPA 99 requires tubing to be cut square using a sharp tubing cutter that shall be
free from grease, oil or other lubricants not suitable for oxygen service. What sort
of treatment is permitted of the tube ends before brazing?


a. May be reamed
b. May be deburred or rolled smooth
c. May be re-cleaned
d. none of the above


Excluding outdoor locations, which of these is an NFPA 99 requirement for the
wiring of each of the two mandatory master alarms?

a.Common conductors
b.Without any splices
c.Wired independently to the initiating device(s) for each signal
d.Alarms shall be sent to the area alarm panel in the emergency room


Inspection and testing shall be performed on all new piped gas systems,
additions, renovations, temporary installations or repaired systems to assure the
facility that all applicable provisions of NFPA 99C have been adhered to and
system integrity has been achieved or maintained. What is required of the
individual doing the testing or inspecting?

a.Have two years experience
b.Have a documented procedure
c.Be a certified tester
d.none of the above


With the approval of the authority having jurisdiction, in what areas shall the
shutoff valves be permitted to be secured to prevent inappropriate access?

a.critical care
b.psychiatric or pediatric
c.maternity
d.anesthetizing

, For purposes of this code, an oxygen enriched atmosphere is an atmosphere
where to total concentration of oxygen exceeds _______ by volume.

a.23.5%
b.23.6%
c.19.5%
d.93%


Compressed gas cylinders must meet which of the following criteria in order to
be acceptable for use in an acute health care facility?

a.Be appropriately identified by labels or stencils in accordance with CGA C-7
criteria
b.Be appropriately color coded in accordance with U.S.D.A. requirements
c.Be constructed in accordance with specifications and regulations of OSHA
d.Utilize gas specific CGA connections


In those portions of the system intended to handle oxygen at pressures greater
than 350 psi, the interconnecting hose shall not contain __________ materials.

a.stainless steel
b.polymeric
c.copper
d.brass


To facilitate service, testing or replacement, all pressure switches and mainline
gauges downstream of the source valve shall be provided with a
________________.

a.Check valve
b.Shutoff valve
c.Demand check fitting
d.D.I.S.S. fitting


Those sections or portions of the piping system that serve a room or group of
rooms on the same story of the facility. This is the definition of which of the
following?
a.Main lines
b.Risers
c.Vent Lines
d.Branch (lateral) lines

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
kartelodoc Harvard University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
120
Lid sinds
1 jaar
Aantal volgers
4
Documenten
8200
Laatst verkocht
1 week geleden

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. I WISH YOU SUCCESS IN YOUR EDUCATION JOURNEY

Lees meer Lees minder
3,2

22 beoordelingen

5
7
4
1
3
7
2
3
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen