100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Engine Fire Protection Systems Exam Questions With Complete Solutions (Updated)

Beoordeling
-
Verkocht
-
Pagina's
3
Cijfer
A+
Geüpload op
03-12-2025
Geschreven in
2025/2026

Engine Fire Protection Systems Exam Questions With Complete Solutions (Updated) In a thermal switch type fire detection system, heat sensitive switches are placed in _______________ with each other, and in _______________ with the flight deck indicator lights. A. parallel; series B. series; parallel C. series; series - Answer- A Which of the following are features of an ideal fire detection system? 1. illuminates a light on the flight deck which indicates the location of the fire 2. sets off an audible alarm 3. low number or no false alarms 4. resettable when the fire is out 5. minimum electrical current requirements A. 1, 3, 5 B. 2, 3, 4, and 5 C. 1, 2, 3, 4, and 5 - Answer- C What is the operating principle of the spot detector sensor in a fire detection system? A. Resistant core material that prevents current flow at normal temperatures. B. fi conventional thermocouple that produces a current flow. C. A bimetallic thermal switch that closes when heated to a high temperature. - Answer- C Which of the following fire detection systems measure temperature rise compared to a reference temperature? A. thermocouple B. thermal switch C. lindberg continuous element - Answer- A Optical fire detection systems A. can be infrared or ultraviolet. B. must be used out of the way of direct sunlight. C. give a false alarm if not disarmed before an incandescent light strikes the sensor. - Answer- A A fire detection system operates on the principle of a buildup of gas pressure within a tube proportional to temperature. Which of the following systems does this statement define? A. kidde continuous-loop system B. lindberg continuous-element system C. thermal switch system - Answer- B What is the principle of operation of the continuous loop fire detection system sensor? A. fuse material which melts at high temperatures B. core resistance material which prevents current flow at normal temperatures C. a bimetallic thermo-switch which closes when heated to a high temperature - Answer- B Which of the following is the safest fire- extinguishing agent to use from a standpoint of toxicity and corrosion hazards? A. dibromodiflouromethane (Halon 1202) B. bromochlorodiflouromethane (Halon 1211) C. bromotriflouromethane (Halon 1301) - Answer- C How is the fire extinguishing agent distributed in the engine section? A. spray nozzles and fluid pump B. nitrogen pressure and slinger rings C. spray nozzles and perforated tubing - Answer- C In a fixed fire-extinguishing system, there are two small lines running from the system and exiting overboard. The line exit ports are covered with a blowout type indicator disc. Which of the following statements is true? A. When the red indicator is missing, it indicates the fire- extinguishing system has been normally discharged. B. When the yellow indicator disc is missing, it indicates the fire-extinguishing system has been normally discharged. C. When the green indicator disc is missing, it indicates the fire-extinguishing system has had a thermal discharge. - Answer- B A common visual check of fire detection elements includes A. the contact points in the control box. B. cracked or broken sections. C. the color of missing blowout disks. - Answer- B If a continuous-loop fire detection system is giving a false alarm, how can it be determined if the problem is in the control unit or in the sensing loop? A. by disconnecting the loop from the control box and observing if the false alarm stops B. by connecting a voltmeter across the connected loop terminals C. by resetting the warning lights and timing the interval until the next false alarm - Answer- A

Meer zien Lees minder
Instelling
Engine Fire Protection Systems
Vak
Engine Fire Protection Systems








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Engine Fire Protection Systems
Vak
Engine Fire Protection Systems

Documentinformatie

Geüpload op
3 december 2025
Aantal pagina's
3
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Engine Fire Protection Systems Exam
Questions With Complete Solutions
(Updated)
In a thermal switch type fire detection system, heat sensitive switches are placed in
_______________ with each other, and in _______________ with the flight deck
indicator lights.
A. parallel; series
B. series; parallel
C. series; series - Answer- A

Which of the following are features of an ideal fire detection system?
1. illuminates a light on the flight deck which indicates the location of the fire
2. sets off an audible alarm
3. low number or no false alarms
4. resettable when the fire is out
5. minimum electrical current requirements
A. 1, 3, 5
B. 2, 3, 4, and 5
C. 1, 2, 3, 4, and 5 - Answer- C

What is the operating principle of the spot detector sensor in a fire detection system?
A. Resistant core material that prevents current flow at normal temperatures.
B. fi conventional thermocouple that produces a current flow.
C. A bimetallic thermal switch that closes when heated to a high temperature. - Answer-
C

Which of the following fire detection systems measure temperature rise compared to a
reference temperature?
A. thermocouple
B. thermal switch
C. lindberg continuous element - Answer- A

Optical fire detection systems
A. can be infrared or ultraviolet.
B. must be used out of the way of direct sunlight.
C. give a false alarm if not disarmed before an incandescent light strikes the sensor. -
Answer- A

A fire detection system operates on the principle of a buildup of gas pressure within a
tube proportional to temperature. Which of the following systems does this statement
define?
A. kidde continuous-loop system

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Stuviaascorers University of Washington
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
346
Lid sinds
2 jaar
Aantal volgers
185
Documenten
10100
Laatst verkocht
4 dagen geleden
StuviaAscorers | Top Study Notes & Exam Solutions

Stuviaascorers – Your #1 Source for Top-Quality Study Materials! Struggling with exams? Stuviaascorers has got you covered! I provide expertly crafted study notes, summaries, past papers, and exam-ready answers to help you pass with flying colors. My materials are designed for clarity, accuracy, and success—so you can study smarter, not harder! Why Choose My Study Materials? Well-structured & easy to understand – No fluff, just what you need! Exam-focused & high-scoring content – Get straight to the point! Accurate answers & clear explanations – Learn with confidence! Save time & boost your grades – Study efficiently! Don’t leave your success to chance! Browse my documents and start acing your exams today!

Lees meer Lees minder
3,8

64 beoordelingen

5
30
4
11
3
11
2
2
1
10

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen