Download the NFPA 99 Practice Test 2025 with verified correct answers. Covers medical gas systems, alarm panels, oxygen piping, bulk gas storage, brazing, safety codes, and installation requirements for ASSE 6010 and healthcare compliance.

Meer zien Lees minder
Instelling
Nfpa
Vak
Nfpa











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Nfpa
Vak
Nfpa

Documentinformatie

Geüpload op
12 oktober 2025
Aantal pagina's
33
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

NFPA-99: PRACTICE TEST QUESTIONS
EXAM WITH CORRECT QUESTIONS
AND ANSWERS 2025

Under which of these conditions shall the instrument Air Reserve header cylinders be permitted


to be stored with the instrument air compressor?


A) the mechanical equipment room does not contain a boiler.


B) the medical air compressors are in the same room.


C) the only motor-driven machinery in the room is for instrument air equipment.


D) the room is secured with lockable doors. - CORRECT-ANSWERSC) The only motor-driven


machinery in the room is for the instrument air equipment


Riser valves are those valves located where?


A) adjacent to the main riser downstream of any zone valve.


B) anywhere in the lateral branches of the piping system.


C) in the mainline adjacent to the base of the riser.


D) in the riser adjacent to the mainline. - CORRECT-ANSWERSD) In the riser adjacent to the


main line


When is the initial pressure test conducted by the installer?

,A) after blowdown of the distribution piping.


B) after installation of alarm sensors.


C) before blowdown of distribution piping.


D) before installation of station rough in assembly. - CORRECT-ANSWERSA) After blow-down of


the distribution piping.


In those portions of systems intended to handle oxygen at pressure greater than 350 psi the


inter connecting hose shall not contain what materials?


A) brass.


B) copper


C) polymeric


D) stainless steel - CORRECT-ANSWERSC) Polymeric


The tool shown here allows the installer to mechanically limit the makeup depth of the fitting


to be brazed. Under what condition is this method permitted for the installation of medical gas


piping?


A) only on final line connectors.


B) only on vacuum systems.


C) where only B cup 5 brazing rod is used

,D) where the limited makeup depth is not less than minimum cut depth her ANSI / ASME


recommendations - CORRECT-ANSWERSD) Where the limited makeup depth is not less than


minimum cup depth current ANSI\ASME recommendation


What is the standard gauge pressure for nitrogen gas service?


A) 15 - 30


B) 50 - 55


C) 162 185


D) it varies with system type. - CORRECT-ANSWERSC) 50 - 55 psi


What is a NFPA 99 requirement for labeling of pipes in medical gas system?


A) color coding


B) fixed label with


C) label shall wrap completely around pipe.


D) reflective label - CORRECT-ANSWERSA) Color coding


A wireless communication device is employed in a medical gas or vacuum warning system. what


type of supervision is required for this device?


A) a visual indicator Shelby located in maintenance officer or engineering department.


B) this device shall be installed at the medical gas or vacuum source.


C) this device shall be located at nurses station.

, D) this device will be supervised such that failure communication shall initiate an alarm. -


CORRECT-ANSWERSD) This device will be supervised such that failure of communication shall


initate an alarm


In a facility where Medical Gas vacuum systems are present and the failure of such equipment


or systems is likely to cause any major injury or death to patients or caregivers this system shall


be designed to meet which category requirements?


A) 1


B) 2


C) 3


D) 4 - CORRECT-ANSWERSA) category 1


A faculty is in the planning stages of installing an emergency oxygen service connection (ESOC).


How many feet is the minimum amount of clearance required around this connection?


A) 1 foot


B) 3 feet


C) 5 feet


D) Clearance must be 1-1/2 times the width of the auxiliary. - CORRECT-ANSWERSB) 3 feet


Wooden rack for cylinder storage may be permitted under which conditions?


A) the wooden must be painted.
€12,27
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
frosty3

Maak kennis met de verkoper

Seller avatar
frosty3 Howard Community College
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
Nieuw op Stuvia
Lid sinds
2 maanden
Aantal volgers
1
Documenten
57
Laatst verkocht
-

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen