100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

BREATH TECH QUESTIONS AND VERIFIED SOLUTIONS

Beoordeling
-
Verkocht
-
Pagina's
6
Cijfer
A+
Geüpload op
20-08-2025
Geschreven in
2025/2026

A QT has the most direct effect of the breath test? T or F - True The intoxilyzer 8000C can measure up to _______ BAC - 600mg/100mL blood What is the proper terminology for the result when the breath test is complete? (saying the accused blew 120) - 120mg of alcohol in 100 mL of blood How long does the power on process for the intoxilyzer 8000C take? - 30 minutes After how many days will the alcohol standard solution expire? - 15 days What must be performed when the configure standard is changed? - configure standard What is the temperature of the simulator and it's acceptable range? - 34 degrees celsius (can be within 0.2) so 33.8 and 34.2 is acceptable What is the target value for the system calibration check and what is it's acceptable range? - - 100 - must be within 10 % either way so 90 or 110 is okay as well Will the intoxilyzer 8000C produce an exception message during an Esc, Esc "C"? - No What makes the most accurate results for a breath test? - deep lung air (alveolar) If someone is hyperventilating (breathing very quickly) what happens to their breath? - cools it If someone is hypoventilating (holding breath) what happens to their breath?

Meer zien Lees minder
Instelling
BREATH TECH
Vak
BREATH TECH









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
BREATH TECH
Vak
BREATH TECH

Documentinformatie

Geüpload op
20 augustus 2025
Aantal pagina's
6
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

BREATH TECH QUESTIONS AND VERIFIED SOLUTIONS
A QT has the most direct effect of the breath test? T or F - ✔✔True The intoxilyzer 8000C
can measure up to _______ BAC - ✔✔600mg/100mL blood What is the proper terminology
for the result when the breath test is complete? (saying the accused blew 120) - ✔✔120mg
of alcohol in 100 mL of blood How long does the power on process for the intoxilyzer
8000C take? - ✔✔30 minutes After how many days will the alcohol standard solution
expire? - ✔✔15 days What must be performed when the configure standard is changed? -
✔✔configure standard What is the temperature of the simulator and it's acceptable range?
- ✔✔34 degrees celsius (can be within 0.2) so 33.8 and 34.2 is acceptable What is the
target value for the system calibration check and what is it's acceptable range? - ✔✔- 100 -
must be within 10 % either way so 90 or 110 is okay as well Will the intoxilyzer 8000C
produce an exception message during an Esc, Esc "C"? - ✔✔No What makes the most
accurate results for a breath test? - ✔✔deep lung air (alveolar) If someone is
hyperventilating (breathing very quickly) what happens to their breath? - ✔✔cools it If
someone is hypoventilating (holding breath) what happens to their breath? - ✔✔warms it
What are the 4 criteria evaluated and must be met before a BAC will be produced? - ✔✔-
flow rate (0.15 L/S) - time (1 second) - volume (1.1 litre) - level slope Approximately what
percentage of available breath must be discarded before "deep lung air" is reached? -
✔✔70% Will a poor quality sample underestimate the BAC? - ✔✔Yes How many "suitable"
samples must be obtained - ✔✔2 Is there a limit on how many samples you can take? -
✔✔no limit How is the second breath test for the subject conducted? - ✔✔Esc, Esc "R" If
you have two tests that are not within 20mg of one another, the third can can be conducted
after ________ minutes - ✔✔17 minutes What are the 3 audible tones? - ✔✔- single tone
(pass) - continuous tone (flow rate met, breath analysis) - high low tone - fail Explain how
the intoxilyzer works in general terms - ✔✔- Breath is blown through an approved
instrument - Breath goes through an infared sensor - Infared detector conducts light energy
to voltage - Result is a mg of alcohol in ml of blood What is the message when the results
are 20mg apart from one another? - ✔✔no 020 agreement (re test subject) What is the
certificate of analyst? - ✔✔- legal document for alcohol standard solution - proves solution
is suitable for accuracy of intoxilyzer 8000C Who is the QT designated by? - ✔✔soliciter
general What does good agreement mean? - ✔✔2 suitable samples that do not differ from
20mg of alcohol in 100 mL of blood What does the certificate of analyst help form? -
✔✔conclusive proof What are 5 times the alcohol standard solution needs to be changed?
- ✔✔- 50 calibration checks conducted - past 15 days (expired) - no certificate of analyst -

, solution expired - system calibration check outside range for unknown reason Can you
purchase an intoxilyzer 8000C from any hardware store? - ✔✔no Is it possible to
incorrectly hook up a simulator to the intoxilyzer 8000C? - ✔✔yes When all 4 criteria are
met what will appear in front of the breath test result? - ✔✔a zero What is the breath test
sequence? - ✔✔- 5 system blank checks - 2 diagnostic checks - 1 system calibration check
- 1 subject test A system blank test cannot be more than _____ mg / 100mL - ✔✔10mg If the
measurement exceeds 10mg/100mL the exception message will be? - ✔✔ambient fail If
the sample chamber could not be decreased to an acceptable alcohol level, what will the
exception message be? - ✔✔purge fail Ambient conditions may lower the system
calibration check and the subject test results. T or F? - ✔✔True What is the purpose of a
diagnostic check? - ✔✔verify the instrument is in proper working order How many
components are there in a diagnostic check? - ✔✔9 Does the QT calibrate the intoxilyzer
8000C? - ✔✔No - all the QT does is CHECK the calibration What are the 3 quality
assurance checks prior to testing and why are they performed? - ✔✔- self test - system
calibration check - diagnostic check These are performed to ensure the intoxilyzer 8000C
is in working order How would you qualify yourself as a qualified technician in court? - ✔✔-
date received training - date of last in service training - published in gazette - approx
number of tests performed to date - designated by soliciter general How would you identify
the approved instrument in court? - ✔✔Intoxilyzer 8000C and serial number How would
you identify the alcohol standard in court? - ✔✔manufacturer and LOT number The
qualified technician is the only person authorized by law to perform breath tests - T or F -
✔✔True How should you coach the subject to provide a breath sample? - ✔✔- take
moderate inhalation - continuous breath at moderate force - continue to provide the
sample until i say stop or the tone stops - demonstrate self breath test Under what 4
circumstances are a diagnostic check conducted? - ✔✔- breath test being conducted -
Esc, Esc "D" - Intoxilyzer starting up - Intoxilyzer coming out of stand by What does ITP
stand for? - ✔✔Internal Test Procedure What is the purpose of ITP? - ✔✔- Occurs when the
amount of IR light that reaches the detectors is decreased to simulate a BAC of mg of
alcohol in 100 mL of blood - makes sure detectors work and checks calibration internally
Why is the simulator heated to 34 degrees celsius? - ✔✔because it is the temperature of
the human breath What are the criteria for the breath alcohol results to be conclusive
proof of BAC at the time of analysis? - ✔✔- approved instrument - operated by QT - system
black test not more than 10mg - system calibration check within 10% of target value -
interval between two tests at least 15 minutes - results rounded down and do not differ by
more than 20mg - use of certified alcohol standard Why would you deem a breath sample
€13,06
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
briannzyoki2008

Maak kennis met de verkoper

Seller avatar
briannzyoki2008 Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
0
Lid sinds
7 maanden
Aantal volgers
0
Documenten
36
Laatst verkocht
-
TutorTrail

Your path to academic confidence.

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen