100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Army Electrical Explosives Safety (AMMO-28) Exam – 2025–2026 – U.S. Military Ordnance Training Accurate Real Exam Questions and Verified Correct Answer

Beoordeling
-
Verkocht
-
Pagina's
24
Cijfer
A+
Geüpload op
24-05-2025
Geschreven in
2024/2025

This document provides the accurate and verified set of real exam-style questions and correct answers for the AMMO-28: Army Electrical Explosives Safety Exam, updated for the 2025–2026 training cycle. It covers essential safety procedures related to electrical hazards and explosives, including static electricity, grounding and bonding, lightning protection, personal protective equipment (PPE), safe handling of electrically initiated devices (EIDs), and relevant Army and DoD explosive safety regulations. Ideal for ammunition specialists, EOD personnel, and military ordnance handlers.

Meer zien Lees minder
Instelling
ARMY ELECTRICAL EXPLOSIVES SAFETY EX
Vak
ARMY ELECTRICAL EXPLOSIVES SAFETY EX

Voorbeeld van de inhoud

ARMY ELECTRICAL EXPLOSIVES SAFETY (AMMO28)
EXAM 2025–2026 Accurate Real Exam Questions
and Verified Correct Answers
Which bonding condition applies to a 65-foot metal antenna? - ANSWER-- condition 1



What does D represent in the Basic Bonding Formula? - ANSWER--bonding distance



How many inches should the tip of an air terminal be above the object or area it protects? -

ANSWER--WRONG 24

WRONG 18



Which statement regarding bonding is true? - ANSWER--Bonding reduces the threat of sideflash by
providing a low impedance path to ground



How many feet radius does the DoD require for an LPS zone of protection? - ANSWER--100ft



While conducting an LPS inspection, you discover the scenario illustrated in the image below. Do you
write it up as a discrepancy? - ANSWER--yes, because the air terminal is not attached to a conductor.



While conducting an LPS inspection, you see down conductors like those illustrated in the image below.
Do you write it up as a discrepancy? - ANSWER-- yes, because mast down conductors should be 180
degrees apart



A 30-foot building has a metal light fixture located 23 feet from the ground. Which condition is used to
determine if the light fixture must be bonded to the LPS? Refer to the bonding job aid as required. -
ANSWER--condition 2a(2)



During an LPS inspection you notice a newly-installed grounded metal pipe 3 feet from a down
conductor.

,Should you write it up as a possible discrepancy? - ANSWER--yes. Grounded metal objects within 6 feet
of a conductor should be considered for bonding



Which bonding method is used where strength and security are most critical? - ANSWER-exothermic
weld




When conducting a fall-of-potential ground resistance test on a facility where ammunition and
explosives are stored, what is the maximum allowable resistance reading for an LPS? - ANSWER--25
ohms




While conducting an LPS inspection, you see the scene in the image below. Does this comply with LPS
standards? - ANSWER--no, because the surveillance cameras are outside the zone of

protection




For best accuracy, how many individual resistance tests should be performed on this conductive floor? -
ANSWER--10 tests: 5 electrode-to-electrode and 5 electrode-to-ground tests




Which test is used to verify the integrity of the LPS grounding system? - ANSWER-- fall-ofPotential
Ground Resistance Test




Which test is used to verify the integrity of air terminals and down conductors? - ANSWER-
continuity/Resistance Test




How many individual continuity/resistance tests are required on an integral LPS with 12 air terminals
and 2 down conductors? - ANSWER--WRONG 12

24

, When performing a conductive floor test, what is the minimum distance required between test
electrodes and grounded metal objects? - ANSWER--WRONG 6 feet




According to the identification plate below, the component is certified for Group C and - ANSWER--
WRONG group B




Which bonding condition applies to isolated metal objects surrounded by non- conductive material (i.e.,
a metal door frame in a brick wall)? - ANSWER--WRONG Condition 1




While conducting a continuity/resistance test on the integral LPS below, test leads are placed on ground
rod S and air terminal N. In addition to bonds A, J, and M, which bond is being tested? - ANSWER--
WRONG H




When conducting a continuity/resistance test on a conductor less than 65 feet long, the maximum
allowable reading is - ANSWER--WRONG 5 ohms

WRONG 25 ohms




When conducting a fall-of-potential ground resistance test on a facility measuring 130 feet diagonally,
how far from the ground rod should the P2 test probe be placed? - ANSWER--65 feet




This conductive floor was tested at 5 locations. All electrode-to-electrode resistance readings were
between 48,000 ohms and 80,000 ohms. Did this particular test pass? Refer to AFI 321065, Section A6.7
as required. - ANSWER-- yes, because any resistance reading above 25,000 ohms is acceptable.

Geschreven voor

Instelling
ARMY ELECTRICAL EXPLOSIVES SAFETY EX
Vak
ARMY ELECTRICAL EXPLOSIVES SAFETY EX

Documentinformatie

Geüpload op
24 mei 2025
Aantal pagina's
24
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€16,55
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
dennohz2000 Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
222
Lid sinds
2 jaar
Aantal volgers
47
Documenten
5308
Laatst verkocht
22 uur geleden

4,1

56 beoordelingen

5
34
4
8
3
6
2
2
1
6

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen