What must you do if you notice code violations in a homeowners house? - ANSWERNotify them and recommend ways to address them What must be done when performing an annual tune-up on a heating system? - ANSWERA combustion efficiency test and a copy must be posted on site Whenever a furnace, direct fired hot water heater, or boiler is installed the total installation must be brought into compliance with what requirements BEFORE appliance can be fired? - ANSWERNFPA 31 When an emergency arises that does not allow adequate time to get a chimney lined/and or repaired before installing the new heating appliance the licensee may defer the required repairs for how long? - ANSWER90 days What must be performed before a new installation? - ANSWERA heat loss system design and load calculation. A copy must be retained to be presented upon request of board inspector All oil fired BOILERS must be provided with a properly installed and operating what? - ANSWERLow Water cut off Where shall a low water cutoff be installed? - ANSWERAt the level recommended by the manufacture, but in no case below the crown sheet If the low water cut off is not installed directly in the boiler where may it be installed? - ANSWERMain supply line (vertical riser) as close to boiler as possible, or in a water column of continuous piping attached directly to the boiler A listed lever or wheel thermally operated oil shut off valve must be installed where? - ANSWERAt the burner and the oil supply tank When outside tanks are used a thermally operated shut off valve must be installed where? - ANSWERThe supply line enters the inside of the building and where the oil line enters the room where the appliance is located When inside tanks are used and the oil supply tank is installed in a separate room, a thermally shutoff valve must be installed where? - ANSWERWhere the line enters the room where the appliance is located Whenever the oil supply is taken from the top of an oil tank a thermally operated wheel or lever type shut-off valve must be installed where? - ANSWERAt the tank and at the burner What may be installed in the supply line but not a return line? - ANSWERA check valve

Meer zien Lees minder
Instelling
JOURNEYMAN OIL MAINE FUEL BOARD RULES
Vak
JOURNEYMAN OIL MAINE FUEL BOARD RULES









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
JOURNEYMAN OIL MAINE FUEL BOARD RULES
Vak
JOURNEYMAN OIL MAINE FUEL BOARD RULES

Documentinformatie

Geüpload op
16 mei 2025
Aantal pagina's
13
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

JOURNEYMAN OIL MAINE FUEL
BOARD RULES QUESTIONS &
ANSWERS(SCORED A+)
What must you do if you notice code violations in a homeowners house? -
ANSWERNotify them and recommend ways to address them

What must be done when performing an annual tune-up on a heating system? -
ANSWERA combustion efficiency test and a copy must be posted on site

Whenever a furnace, direct fired hot water heater, or boiler is installed the total
installation must be brought into compliance with what requirements BEFORE
appliance can be fired? - ANSWERNFPA 31

When an emergency arises that does not allow adequate time to get a chimney
lined/and or repaired before installing the new heating appliance the licensee may
defer the required repairs for how long? - ANSWER90 days

What must be performed before a new installation? - ANSWERA heat loss system
design and load calculation. A copy must be retained to be presented upon request
of board inspector

All oil fired BOILERS must be provided with a properly installed and operating what?
- ANSWERLow Water cut off

Where shall a low water cutoff be installed? - ANSWERAt the level recommended by
the manufacture, but in no case below the crown sheet

If the low water cut off is not installed directly in the boiler where may it be installed?
- ANSWERMain supply line (vertical riser) as close to boiler as possible, or in a
water column of continuous piping attached directly to the boiler

A listed lever or wheel thermally operated oil shut off valve must be installed where?
- ANSWERAt the burner and the oil supply tank

When outside tanks are used a thermally operated shut off valve must be installed
where? - ANSWERThe supply line enters the inside of the building and where the oil
line enters the room where the appliance is located

When inside tanks are used and the oil supply tank is installed in a separate room, a
thermally shutoff valve must be installed where? - ANSWERWhere the line enters
the room where the appliance is located

Whenever the oil supply is taken from the top of an oil tank a thermally operated
wheel or lever type shut-off valve must be installed where? - ANSWERAt the tank
and at the burner

, What may be installed in the supply line but not a return line? - ANSWERA check
valve

All copper oil supply and return lines must be encased in a continuous piece of no
metallic liquid tight conduit such as PVC, ENT, coated copper tubing. The end of the
conduit shall not exceed how far from any connection except the connection at fuel
tank? - ANSWER2 inches

In order to avoid undetected oil leaks under floors, the conduit must be how much
bigger than the supply and return lines? - ANSWEROne pipe size larger

An oil supply line that penetrates a foundation wall must be what? - ANSWERSealed

What must coated copper tubing have installed at the tank when used underground?
- ANSWEROils Safety Valve or PRV

When an oil filter or other accessory equipment is connected to a copper piping
smaller than 3/4 "and is not directly connected to the oil tank or burner the filter or
other device must be what? - ANSWERRigidly supported by wall or floor mounted
brackets

What must supply and return lines be connected with? - ANSWERFlare fittings

What fittings shall not be used unless for introduction of lines at top of the tank with a
single or double tap bushing? - ANSWERCompression fittings

All connections of supply or return oil lines located outside must be made with what?
- ANSWERFlare frost fittings

Manholes 16 inches in diameter or larger must be installed in the top of all tanks over
what? - ANSWER5,000 gallons or more

All fuel oil supply tanks must be a minimum of how many feet from any gas or solid
fuel burning appliance? - ANSWER5 feet

Outside oil tanks shall not be installed on what? - ANSWERWood or other
combustible surfaces

In all tank instillation's the pipe flanges must be in direct contact with reinforced
concrete pad or solid concrete blocks, what is not permitted? - ANSWERUse of
shims

In order to prevent oil spills, outside tanks and piping must be located such that they
are not subject to snow or falling ice. To meet this requirement the tank and outdoor
piping must be installed where? - ANSWERWith a protective cover over tank valve,
oil filter, and any piping which is either without structural support or not attached of
side of building
€14,06
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
papersbyjol West Virginia
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
421
Lid sinds
2 jaar
Aantal volgers
253
Documenten
13947
Laatst verkocht
2 dagen geleden

3,8

72 beoordelingen

5
27
4
18
3
17
2
2
1
8

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen