100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ABYC Systems Certification Exam Review questions and answers with solutions

Beoordeling
-
Verkocht
1
Pagina's
39
Cijfer
A+
Geüpload op
25-04-2025
Geschreven in
2024/2025

ABYC Systems Certification Exam Review questions and answers with solutions

Instelling
ABYC Marine Electrical
Vak
ABYC Marine Electrical











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
ABYC Marine Electrical
Vak
ABYC Marine Electrical

Documentinformatie

Geüpload op
25 april 2025
Aantal pagina's
39
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

ABYC Systems Certification Exam Review questions
and answers with solutions

What is the most often used materials for potable water systems? - ANSWER Polyethylene



Name 5 materials allowable for contact use in potable water systems: - ANSWER 1. Copper
Alloys (incl. bronze, brass and nickel-copper)

2. AISI Type 300 series stainless steel

3. Glass-lined metal

4. FDA approved plastic

5. FDA approved rubber



What device can be used to separate potable water from other water systems? - ANSWER
Siphon Break



What is the device used to maintain a stable pressure and minimize pump cycling, and where
should it be located? - ANSWER Accumulator Tank, after pump/filter and before check-valve



At what what percentage of nominal working pressure shall the relief valve be set? - ANSWER
175%



Is a standard household type relief valve acceptable for hot water tanks? - ANSWER No, typically
these are too high (up to 400% of nominal pressure)



For the pressure reducing valve and check valve installed after a shore water connection, what
is the maximum allowable pressure? - ANSWER nominal working pressure, not to exceed 80 PSI



Where shall the storage tank be vented? - ANSWER overboard

,What is the maximum allowable pressure to which the storage tank and vent system be
subjected? - ANSWER 3 PSI or mnfg's maximum, which ever is greater.



What temperate range is required for pumps to be able to tolerate exposure? - ANSWER -40 °F
to +140 °F



When operating at an ambient temperature of 140 F, what is the max allowable surface
temperature of a pump? - ANSWER 257 F



Potable water systems must be equipped with a drain. T or F? - ANSWER True



Storage tank inlet may also serve as the tank vent. T or F? - ANSWER False



Storage tank inlet caps must be retained to prevent loss. T or F? - ANSWER True



Storage tanks must be equipped with a vent. T or F? - ANSWER True



Storage tank vent may be used for filling purposes. T or F? - ANSWER True



What rate of static pressure must a storage tank withstand? - ANSWER At least 1.5X the
pressure exerted by the distance from the tank bottom to the deck fill plate or vent, but not less
than 3 PSI.



What is the max pressure that a desalinator can impart to a storage tank? - ANSWER 3 PSI



Each desalinator must be equipped with an automatic shutoff salinity detector. T or F? -
ANSWER True

,What marking must be on pipe or tubes that are not capable of handling hot water? - ANSWER
"For Cold Water Use Only"



What is the test pressure for water heater tank 15 gal or less? over 15 gal but under 120 gal? -
ANSWER 125 PSI, 300 PSI



What is the max pressure relief valve setting for hot water tanks? - ANSWER 175 PSI



What is the max temperature relief setting for hot water tanks? - ANSWER 210 F



What is the max allowable water output temperature for hot water system? - ANSWER 125 F



All potable water system connections shall be positioned above the normal bilge water
accumulation level. T or F? - ANSWER True



Exposed metallic parts of a potable water system shall have provisions for electrical bonding. T
or F? - ANSWER True



For what reason might a holding tank collapse during pump-out? - ANSWER Improper venting



What type of MSD (Marine Sanitation Device) discharges effluent with fecal coliform bacteria
count <= 1,000 (per 100 ml) and no suspended solids? - ANSWER Type I



What type of MSD (Marine Sanitation Device) discharges effluent with fecal coliform bacteria
count <= 200 (per 100 ml) and <= 150 mg suspended solids per liter? - ANSWER Type II

, What type of MSD (Marine Sanitation Device) is designed to hold sewage or any waste derived
from sewage? - ANSWER Type III



What is the name given to the complete system including toilets, hoses, pipes, holding tanks
and fittings designed to receive, retain, vent and pump out sewage? - ANSWER Retention
System



What is the name of the system that includes all sanitation equipment and fittings designed to
receive, treat, vent and discharge sewage? - ANSWER Treatment System



What is another name for a vented loop that prevents back siphoning by breaking suction yet
allowing normal flow when pressurized? - ANSWER Siphon break



When calculating holding tank size, how many flushes per day are included in the calculation? -
ANSWER 5



What volume of human waste is used per flush when calculating holding tank size? - ANSWER
0.14 gallons



True or False: If a portable toilet is secured and fitted with a deck pump-out fitting and vent it
qualifies as a type III device. - ANSWER True



Why must careful consideration be given to the location and routing of inlet and discharge lines
for manual flush toilets when the "shut-off" merely bleeds air into the inlet line? - ANSWER
Prevention of siphoning



When and why must siphon breaks be installed in a sewage system? - ANSWER Whenever
components are installed below the max heeled water line - to prevent back flow into the vessel
or unintentional siphoning of untreated effluent overboard.
€13,06
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TargeterWings NURSING
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
19
Lid sinds
1 jaar
Aantal volgers
0
Documenten
240
Laatst verkocht
1 week geleden
YOU

I know how frustrating it can get with all those assignments mate. Nursing Being my main profession line, i have essential guides that are A graded, I am a very friendly person so don

4,5

4 beoordelingen

5
2
4
2
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen