100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

EPA Section 608 Universal Certification Pre-assessment questions and answers 2025

Beoordeling
-
Verkocht
-
Pagina's
9
Cijfer
A+
Geüpload op
17-04-2025
Geschreven in
2024/2025

EPA Section 608 Universal Certification Pre-assessment questions and answers 2025

Instelling
EPA 608
Vak
EPA 608









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
EPA 608
Vak
EPA 608

Documentinformatie

Geüpload op
17 april 2025
Aantal pagina's
9
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

EPA Section 608 Universal Certification Pre-assessment
questions and answers 2025

What should be done to reduce refrigerant loss from a purge unit on a R-123 chiller? - ANSWER
Repair the leak in the system



To raise the pressure of a low-pressure refrigeration system for leak checking, you can -
ANSWER Heat the system by circulating hot water, raising the temperature of the room, or using
heating blankets



Low-pressure systems must be evacuated to - ANSWER 25 mm of Hg absolute before being
discarded.



Purge units are required on low-pressure chillers because? - ANSWER these systems operate
below atmospheric pressure.



What is the safety classification of R-123 - ANSWER B1



hydrostatic tube test kit is used to? - ANSWER find leaks in the tube.



What is a valid reason to request an extension from the EPA on the appliance leak repair
deadline? - ANSWER Local permit regulation make the repair within 30 days impossible AND
more time is needed to obtain the necessary repair parts from the manufacturer.



For low pressure chiller, it is best to begin refrigerant recovery with ______ removal to avoid
freezing of the water in the chiller barrels - ANSWER liquid.



Every recovery and recycling unit must be _____________. - ANSWER labeled as certified to
meet EPA's requirements

, The best method to determine a chiller's normal charge for leak rate calculations is to - ANSWER
use the charge stated on the equipment nameplate.



What safety precautions should be adhered to for low-pressure systems? - ANSWER Use gloves
and safety goggles when working with liquid refrigerant.



If possible, the temperature of the equipment room where the chiller is located ______. -
ANSWER Should be increased to speed recovery



To prevent freezing, when recharging an evacuated water-cooled chiller system with R-123, first
charge with vapor to a pressure of at least _______________. - ANSWER 20 in Hg vacuum



When evacuating a system and the freezing of moisture in the system is preventing you from
achieving a deep vacuum, it may be necessary to prevent freezing by - ANSWER increasing the
system pressure with nitrogen



The typical design burst pressure for a rupture disk on a low-pressure centrifugal air-
conditioning system is ______________ . - ANSWER 15 psig



A water-cooled recovery unit typically has a _________________. - ANSWER lower recovery
tank pressure and therefore faster recovery rate



The owners and operators of any system that has 50 or more pounds of refrigerant charge must
keep records of refrigerant added, leak inspections, initial verification tests, and follow-up
verification tests for at least _______. - ANSWER 3 years



The saturation pressure corresponding to 32 °F for R-123 is - ANSWER 20 inches of HG vacuum
€12,71
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Performance Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
321
Lid sinds
1 jaar
Aantal volgers
38
Documenten
15402
Laatst verkocht
3 dagen geleden

Get everything you need to ace your classes in one place. We offer instant downloads of test banks, easy-to-read study guides, step-by-step homework help, and sample research papers to save you hours of work. Whether you're prepping for a big final or stuck on a tough assignment, our resources give you the exact shortcuts and practice you need to boost your grades fast. Stop stressing and get the competitive edge you need to succeed right now

Lees meer Lees minder
4,4

218 beoordelingen

5
128
4
60
3
20
2
4
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen