Fluoroscopy Exam Questions Complete Verified Solutions 2025 Update Total filtration permanently required in the useful fluoroscopic beam should not be less than - Answers - 2.5mm Aluminum If X-ray source is below the table, useful beam exposure must be measured at what distance above the table top - Answers - 30 cm Table top exposure rates for units without auto exposure control must be measured every - Answers - 3 years Dark adaptation for the eye takes how long - Answers - 30 minutes Target-to-tabletop distance must be greater than and should be greater than... - Answers - 12 and 18 inches Integration time for brain to recognize an object - Answers - 0.2 seconds Most scatter occurs at which direction from the primary beam - Answers - 135 degrees mA setting for spot filming where a spot film camera is not used - Answers - 150 mA Greatest dose to the patient comes from spot filming cameras using this film size - Answers - 105 mm SI unit analogous to the rad is - Answers - Gray _________ is a variation in density resulting from the random spatial distribution of quanta. - Answers - Quantum sink SI unit analogous to the rem - Answers - Sievert (unit) Exposure reduction of .25 mm lead - Answers - 97% Scattered radiation received is proportional to - Answers - Dose received by the patient Most effective medium for static viewing in terms of reducing patient dose - Answers - Video disc recorder Contrast of the image intensifying tube is measured by - Answers - conversion factor maximum magnification for cinefluorography is done via which method - Answers - total over framing Ratio of photons that leave the output phosphor to the number of Xray photons that strike the input phosphor - Answers - Flux gain Half value layer determines which characteristic of the Xray - Answers - Xray quality Ability to distinguish separate objects in line pairs per mm - Answers - Resolving power The portion of the image intensifier responsible for magnification - Answers - electrostatic lenses resolution of a 9 inch image intensifier tube - Answers - 3.5 line pairs per millimeter light photons intercepting when electrons strike a fluorescent screen forms a... - Answers - Real image Fluoro with a grid in place affects exposure rates how - Answers - 1.5-2 x higher Greatest radiosensitivity of fetus occurs when - Answers - 2-8 weeks gestation The quantity of the beam is controlled by which unit of measurement - Answers - miliamperage Which fluoroscopic method gives patient dose reduction of up to to 95%? - Answers - video disc recorder 100erg/gram is equivalent to? - Answers - 1 rad Fluoro units with AECs or CINE cameras must have physicist calibration how often - Answers - every year Which imaging modality has the best resolution - Answers - Radiograph Compared to the input phosphor, the image output phosphor is... - Answers - Smaller and brighter As spot film size increases, what happens to the patient dose? - Answers - Patient dose increases Unit used to specify the quality of an X-ray beam - Answers - HVL cycles per time unit in a TV camera is known as... - Answers - bandwidth types of pick-up tubes - Answers - plumicon, vidicon, orthicon TV camera element which converts light to an electric signal - Answers - Pickup Output intensity is measured in... - Answers - mR or R Brightness ratio of the periphery to the center of the output screen is termed: - Answers - Contrast How is resolving power measured? - Answers - Line pairs per milimeter Which factors produce a brighter image at the output phosphor? - Answers - Flux gain and minification What type of TV system has all its signals carried through cables? - Answers - Closed circuit TV Output intensity of a tube is measured in... - Answers - Miliroentgens Electronic intensification occurs when... - Answers - Electrons are moved at high speed from photocathode to output phosphor

Meer zien Lees minder
Instelling
Fluoroscopy
Vak
Fluoroscopy









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Fluoroscopy
Vak
Fluoroscopy

Documentinformatie

Geüpload op
25 maart 2025
Aantal pagina's
11
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Fluoroscopy Exam Questions Complete
Verified Solutions 2025 Update
Total filtration permanently required in the useful fluoroscopic beam should not be less
than - Answers -✔✔ 2.5mm Aluminum

If X-ray source is below the table, useful beam exposure must be measured at what
distance above the table top - Answers -✔✔ 30 cm

Table top exposure rates for units without auto exposure control must be measured
every - Answers -✔✔ 3 years

Dark adaptation for the eye takes how long - Answers -✔✔ 30 minutes

Target-to-tabletop distance must be greater than and should be greater than... -
Answers -✔✔ 12 and 18 inches

Integration time for brain to recognize an object - Answers -✔✔ 0.2 seconds

Most scatter occurs at which direction from the primary beam - Answers -✔✔ 135
degrees

mA setting for spot filming where a spot film camera is not used - Answers -✔✔ 150 mA

Greatest dose to the patient comes from spot filming cameras using this film size -
Answers -✔✔ 105 mm

SI unit analogous to the rad is - Answers -✔✔ Gray

_________ is a variation in density resulting from the random spatial distribution of
quanta. - Answers -✔✔ Quantum sink

SI unit analogous to the rem - Answers -✔✔ Sievert (unit)

Exposure reduction of .25 mm lead - Answers -✔✔ 97%

Scattered radiation received is proportional to - Answers -✔✔ Dose received by the
patient

Most effective medium for static viewing in terms of reducing patient dose - Answers -
✔✔ Video disc recorder

, Contrast of the image intensifying tube is measured by - Answers -✔✔ conversion factor

maximum magnification for cinefluorography is done via which method - Answers -✔✔
total over framing

Ratio of photons that leave the output phosphor to the number of Xray photons that
strike the input phosphor - Answers -✔✔ Flux gain

Half value layer determines which characteristic of the Xray - Answers -✔✔ Xray quality

Ability to distinguish separate objects in line pairs per mm - Answers -✔✔ Resolving
power

The portion of the image intensifier responsible for magnification - Answers -✔✔
electrostatic lenses

resolution of a 9 inch image intensifier tube - Answers -✔✔ 3.5 line pairs per millimeter

light photons intercepting when electrons strike a fluorescent screen forms a... -
Answers -✔✔ Real image

Fluoro with a grid in place affects exposure rates how - Answers -✔✔ 1.5-2 x higher

Greatest radiosensitivity of fetus occurs when - Answers -✔✔ 2-8 weeks gestation

The quantity of the beam is controlled by which unit of measurement - Answers -✔✔
miliamperage

Which fluoroscopic method gives patient dose reduction of up to to 95%? - Answers -
✔✔ video disc recorder

100erg/gram is equivalent to? - Answers -✔✔ 1 rad

Fluoro units with AECs or CINE cameras must have physicist calibration how often -
Answers -✔✔ every year

Which imaging modality has the best resolution - Answers -✔✔ Radiograph

Compared to the input phosphor, the image output phosphor is... - Answers -✔✔
Smaller and brighter

As spot film size increases, what happens to the patient dose? - Answers -✔✔ Patient
dose increases
€12,85
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Stuviaascorers University of Washington
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
345
Lid sinds
2 jaar
Aantal volgers
185
Documenten
10034
Laatst verkocht
3 dagen geleden
StuviaAscorers | Top Study Notes & Exam Solutions

Stuviaascorers – Your #1 Source for Top-Quality Study Materials! Struggling with exams? Stuviaascorers has got you covered! I provide expertly crafted study notes, summaries, past papers, and exam-ready answers to help you pass with flying colors. My materials are designed for clarity, accuracy, and success—so you can study smarter, not harder! Why Choose My Study Materials? Well-structured & easy to understand – No fluff, just what you need! Exam-focused & high-scoring content – Get straight to the point! Accurate answers & clear explanations – Learn with confidence! Save time & boost your grades – Study efficiently! Don’t leave your success to chance! Browse my documents and start acing your exams today!

Lees meer Lees minder
3,8

64 beoordelingen

5
30
4
11
3
11
2
2
1
10

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen