100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

the ULTIMATE Fire Alarm State Test Study Guide Part 2 quiz with actual answers 2025 (1).

Beoordeling
-
Verkocht
-
Pagina's
13
Cijfer
A+
Geüpload op
11-03-2025
Geschreven in
2024/2025

the ULTIMATE Fire Alarm State Test Study Guide Part 2 quiz with actual answers 2025 (1).

Instelling
OHIO FIRE ALARM
Vak
OHIO FIRE ALARM









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
OHIO FIRE ALARM
Vak
OHIO FIRE ALARM

Documentinformatie

Geüpload op
11 maart 2025
Aantal pagina's
13
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

the ULTIMATE Fire Alarm State Test Study
Guide Part 2 quiz with actual answers
2025.



To ensure that audible public mode signals are clearly heard, they shall have a sound
level of at least ? db above the average ambient or ? db above the maximum sound
level having a duration of at least 60 seconds - ANSWER: 15, 5

What type of fire alarm system transmits alarms to a public fire service communications
center? - ANSWER: Municipal fire alarm system

For smoke detector spacing on peaked ceilings, detectors shall be spaced and located
within ? feet of the peak measured along the horizontal axis - ANSWER: 3

For smooth ceilings, all points on the ceiling shall have a detector within a distance
equal to ? times the selected spacing - ANSWER: .5

You must be certified by the state of Ohio if you are:

a. installing fire pumps
b. installing fire alarm systems
c. testing and inspecting fire alarm systems - ANSWER: all of the above

The number of waterflow initiating devices permitted to be connected to a single
initiating device circuit shall not exceed - ANSWER: 5

The maximum distance of a pull station from the means of egress is ? - ANSWER: 5
feet

Initiating device circuits and signaling line circuits that transmit an alarm or supervisory
signal, or notification appliance circuit that allow all connected devices to operate during
a single open or non simultaneous single ground fault shall be designated as ? -
ANSWER: Class A

, A smoke detector cannot be installed in the following condition unless rated for the
appilication:

a. Temps below 32 degrees
b. Temps above 100 degrees
c. Humidity above 93%
d. Air velocity above 300 ft/min - ANSWER: All of the above

Fire alarm systems that are monitored by a central service station are required to be
connected to ? telephone lines - ANSWER: two

What classification are smoke detectors installed and used to prevent the control of
smoke spread by initiation controls of doors, fans, and dampers?

a. Area smoke detectors that are installed in the rated smoke compartments
b. Detectors installed in the duct system - ANSWER: both

A sprinkler valve tamper switch is an example of a ? - ANSWER: supervisory device

The number of supervisory devices permitted to be connected to a single initiating
device circuit shall not exceed - ANSWER: twenty

A signalling method characterized by simultaneous or sequential transmission or both,
and reception of multiple signals on a signaling line circuit, a transmission channel, or a
communications channel, including means for positively identifying each signal -
ANSWER: multiplexing

A device that responds when the temperature rises at a rate exceeding a predetermined
value is a ? detector - ANSWER: rate of rise heat detector

For spot type smoke detectors ? feet shall be permitted to be used as a guide -
ANSWER: 30 feet

A fire alarm system is required to have ? sources of power - ANSWER: 2

Fire pumps shall be supervised for

a. loss of power
b. phase reversal
c. pump run - ANSWER: all of the above
€9,18
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
PageTurners
3,0
(2)

Maak kennis met de verkoper

Seller avatar
PageTurners Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
9
Lid sinds
11 maanden
Aantal volgers
0
Documenten
1458
Laatst verkocht
4 dagen geleden
WHITE ORCHID STORE

EXCELLENCY IN ACCADEMIC MATERIALS ie exams, study guides, testbanks ,case, case study etc

3,0

2 beoordelingen

5
0
4
0
3
2
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen