100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ACI Certification Test. All Revision Questions and Correct Answers (Already Graded A+) (2024 Update) 100% Guarantee

Beoordeling
-
Verkocht
-
Pagina's
17
Cijfer
A+
Geüpload op
05-02-2025
Geschreven in
2024/2025

ACI Certification Test. All Revision Questions and Correct Answers (Already Graded A+) (2024 Update) 100% Guarantee

Instelling
ACI Certification
Vak
ACI Certification










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
ACI Certification
Vak
ACI Certification

Documentinformatie

Geüpload op
5 februari 2025
Aantal pagina's
17
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

ACI Certification Test. All Revision Questions and Correct Answers (Already Graded A+)
(2024 Update) 100% Guarantee




C1064/C1064M - ANSWER- Standard test method for temperature for concrete



C172/C172M - ANSWER- Standard practice for sampling concrete



C143/C143M - ANSWER- Standard testing for Slump



C138/C138M - ANSWER- Standard test method for Density (unit weight), yield, and air
content (Gravimetric)


C231/C231M - ANSWER- Standard test method for Air Content (Pressure Method)



C173/C173M - ANSWER- Standard test method for Air Content (Volumetric Method)



C31/C31M - ANSWER- Stand Practice for making and curing conrete test specimens in field


C1064/C1064M
The end of hte temperature sensing portion of hte temperature measuring device is submerged a
minimum of _______ or _______" into the freshly mixed concrete - ANSWER- 75mm or 3"


C1064/C1064M
The Temperature measuring device shall be capable of accurately measuring hte temperature of
Freshly mixed concrete to _________ throughout a range of _________ - ANSWER- 0.5
degree C (1 degree F) and 50 degree C (30fF - 120F)


C1064/C1064M

,The temperature measuring device shall be verified___________, or whenever there is a question
of___________ - ANSWER- Annually or Accuracy


C1064/C1064M

The temperature of concrete may be measured in a wheelbarrow T/F? - ANSWER- True


C1064/C1064M

The temperature of concrete may be measured in a wall form T/F - ANSWER- True


C1064/C1064M
A composite sample of concrete is required EVEN if the only purpose for obtaining hte sample is
to determine the temperature T/F - ANSWER- False


C1064/C1064M

What must be done to the sample container prior to sampling hte concrete - ANSWER-
Dampened (With Water)


C1064/C1064M
What must be done to the concrete surrounding the temperature masuring device after the device
is submerged in the fresh concrete? - ANSWER- Gently press the concrete around the
temperature masuring device at the surface of the concrete


C1064/C1064M
How long must the temperature measuring device remain in the freshly mixed concrete? -
ANSWER- 2 min, no more than 5 min


C1064/C1064M

After the temperature of the concrete is read, what is then required - ANSWER- Recording the
Temperature

, C1064/C1064M

The temperature of the concrete is reported to the nearest - ANSWER- 0.5 degree C (1 degree
F)


C1064/C1064M
According to the test method C1064/C1064M, what is one reason to take the temperature of the
concrete - ANSWER- Verify conformance to specified requirement for temperature of concrete


C1064/C1064M
A maximum temperature of Freshly mixed concrete is specified in Test method of C1064/C1064M
- ANSWER- FALSE, its in the spec from the owner


C1064/C1064M
The sample of concrete used for temperature determination must be rodded 25 times T/F -
ANSWER- FALSE


C172/C172M
Sampling by this practice covers procedures for obtaining representative samples, on which test
are to be performed to determine______________ with quality requirements of the specifications
under which concrete is furnished - ANSWER- Compliance


C172/C172M
This practice covers sampling from five types of equipment, which are ___________,
______________, ___________,_____________, and ____________ - ANSWER- Stationary
mixers, paving mixers, revolving drum mixers, continous mixers, and open top mixers


C172/C172M
The elapsed time between obtaining the first and final portion of a composite sample shall not
exceed ________- - ANSWER- 15 minutes


C172/C172M
€7,53
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
LECTpharis California University Of Pennsylvania
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
29
Lid sinds
2 jaar
Aantal volgers
2
Documenten
4264
Laatst verkocht
1 maand geleden
The Valedictorians' Hub

Get well-researched exam revision papers with correct answers for A+ grades.

5,0

5 beoordelingen

5
5
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen