EPA 608 Type 1 Exam Questions Fully Solved Latest Update 2025 Already Passed Technicians who perform sealed system service on small appliances must have; - Answers Type I or Universal certification. A small appliance is defined by EPA as; - Answers Appliances manufactured, charged, and hermetically sealed in a factory with 5 Lbs or less of refrigerant Type I Certification is required for; - Answers persons handling refrigerant during maintenance, service, or repair of small appliances If regulations change after the technician becomes certified; - Answers The technician is responsibility for complying with any future changes in the regulations. Recovery equipment manufactured after November 15, 1993 must be; - Answers capable of recovering 90% of the refrigerant in the compressor os operating; 80% of refrigerant if its not or 4 inches of vaccum Which of the following is true of small appliances refrigerant leaks; - Answers EPA does not require repair, but leaks should be repaired whenever possible. Recovery equipment manufactured after November 15, 1993 must be capable of recovering; - Answers 90% refrigerant or or achieving 4 inches of vacuum. Recovering multiple types of refrigerants in the same cylinder; - Answers will make the reclaimed refrigerants non reclaimable and a charge for disposal may be levied. Self-contained or active recovery equipment; - Answers Has its own means of recovery. System-dependant or passive recovery equipment; - Answers Captures refrigerant into a non-pressurized container with assistance of the appliance compressor. What is defined as a non-condensible? - Answers Air When using a system-dependent recovery system on an appliance that has an operating compressor, the technician should; - Answers Run the compressor and recover from the high side of the system. When using a system-dependent recovery system on an appliance that has a non-operating compressor, the technician should; - Answers Place access fitting on both the low and high side of the system. System-dependant devices may only be used on appliances containing; - Answers 15 pounds of refrigerant or less. Small appliances are equipped with a straight piece of tubing (process stub) used to; - Answers install a piercing type access valve fitting. If a strong odor is detected while performing the recovery process, - Answers A compressor burnout has likely occurred. After the refrigerant has been recovered, which of the following can be used to flush the system? - Answers Nitrogen When filling a charging cylinder with a regulated refrigerant; - Answers The refrigerant vapor that is vented off the top of the cylinder must be recovered. If after installing a fitting for the purpose of recovering the appliances refrigerant, you find that the system pressure is 0 psig; - Answers Recovery is not required. Applying heat with a heat gun to the compressor; - Answers can help vaporize any trapped liquid refrigerant during recovery. Refrigerators in the 1950's and earlier may have used what refrigerants (recovery is not required)? - Answers Methyl Formate, Methyl Chloride, or Sulfur Dioxide. Small appliances in recreational vehicles may use refrigerants such as Ammonia, Hydrogen, or water, and therefore; - Answers The refrigerant should not be recovered. Recovery equipment manufactured before November 15, 1993 must be capable of recovering. - Answers 80 percent of the refrigerant or achieving 4 inches of vacuum. When pressurizing a system with nitrogen you should; - Answers charge through a pressure regulator;place a relief valve in the downstream line from the pressure regulator. After recovering refrigerant, the Nitrogen used to flush the system may be: - Answers legally vented. The sale of CFCs and HCFC's are - Answers restricted to certified technicians ARI 740 sets - Answers recovery requirements All equipment must be equipped with - Answers low loss fittings Low loss fittings should be able to - Answers close manually or automatically when hoses are disconnected to minimize refidgerant loss Before beginning a refrigerant recovery procedure, it is necessary - Answers to know the type of refrigerant that is in the system. self contained (active) recovery equipment stores itself in a - Answers pressurized recovery tank Before opening a self contained recovery machine make sure the - Answers inlet valve is open, and tank does not contain excessive air (non condensables) The only way to read refrigerant pressure correctly is at - Answers a stable known temperature Air in refrigeration systems will cause - Answers higher discharge pressures When purging non-condensables abide by - Answers operating instruction supplied by equipment manfactuer All refrigerant recovery equipment should be check for what on a daily basis - Answers oil level and leaks A system dependent recovery unit has - Answers special charcoal activated plastic "bag" containers

Meer zien Lees minder
Instelling
EPA 608 Type 1
Vak
EPA 608 Type 1









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
EPA 608 Type 1
Vak
EPA 608 Type 1

Documentinformatie

Geüpload op
1 februari 2025
Aantal pagina's
6
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

EPA 608 Type 1 Exam Questions Fully Solved Latest Update 2025 Already Passed

Technicians who perform sealed system service on small appliances must have; - Answers Type I or
Universal certification.

A small appliance is defined by EPA as; - Answers Appliances manufactured, charged, and hermetically
sealed in a factory with 5 Lbs or less of refrigerant

Type I Certification is required for; - Answers persons handling refrigerant during maintenance, service,
or repair of small appliances

If regulations change after the technician becomes certified; - Answers The technician is responsibility
for complying with any future changes in the regulations.

Recovery equipment manufactured after November 15, 1993 must be; - Answers capable of recovering
90% of the refrigerant in the compressor os operating; 80% of refrigerant if its not or 4 inches of vaccum

Which of the following is true of small appliances refrigerant leaks; - Answers EPA does not require
repair, but leaks should be repaired whenever possible.

Recovery equipment manufactured after November 15, 1993 must be capable of recovering; - Answers
90% refrigerant or or achieving 4 inches of vacuum.

Recovering multiple types of refrigerants in the same cylinder; - Answers will make the reclaimed
refrigerants non reclaimable and a charge for disposal may be levied.

Self-contained or active recovery equipment; - Answers Has its own means of recovery.

System-dependant or passive recovery equipment; - Answers Captures refrigerant into a non-
pressurized container with assistance of the appliance compressor.

What is defined as a non-condensible? - Answers Air

When using a system-dependent recovery system on an appliance that has an operating compressor,
the technician should; - Answers Run the compressor and recover from the high side of the system.

When using a system-dependent recovery system on an appliance that has a non-operating compressor,
the technician should; - Answers Place access fitting on both the low and high side of the system.

System-dependant devices may only be used on appliances containing; - Answers 15 pounds of
refrigerant or less.

Small appliances are equipped with a straight piece of tubing (process stub) used to; - Answers install a
piercing type access valve fitting.

If a strong odor is detected while performing the recovery process, - Answers A compressor burnout has
likely occurred.

, After the refrigerant has been recovered, which of the following can be used to flush the system? -
Answers Nitrogen

When filling a charging cylinder with a regulated refrigerant; - Answers The refrigerant vapor that is
vented off the top of the cylinder must be recovered.

If after installing a fitting for the purpose of recovering the appliances refrigerant, you find that the
system pressure is 0 psig; - Answers Recovery is not required.

Applying heat with a heat gun to the compressor; - Answers can help vaporize any trapped liquid
refrigerant during recovery.

Refrigerators in the 1950's and earlier may have used what refrigerants (recovery is not required)? -
Answers Methyl Formate, Methyl Chloride, or Sulfur Dioxide.

Small appliances in recreational vehicles may use refrigerants such as Ammonia, Hydrogen, or water,
and therefore; - Answers The refrigerant should not be recovered.

Recovery equipment manufactured before November 15, 1993 must be capable of recovering. -
Answers 80 percent of the refrigerant or achieving 4 inches of vacuum.

When pressurizing a system with nitrogen you should; - Answers charge through a pressure
regulator;place a relief valve in the downstream line from the pressure regulator.

After recovering refrigerant, the Nitrogen used to flush the system may be: - Answers legally vented.

The sale of CFCs and HCFC's are - Answers restricted to certified technicians

ARI 740 sets - Answers recovery requirements

All equipment must be equipped with - Answers low loss fittings

Low loss fittings should be able to - Answers close manually or automatically when hoses are
disconnected to minimize refidgerant loss

Before beginning a refrigerant recovery procedure, it is necessary - Answers to know the type of
refrigerant that is in the system.

self contained (active) recovery equipment stores itself in a - Answers pressurized recovery tank

Before opening a self contained recovery machine make sure the - Answers inlet valve is open, and tank
does not contain excessive air (non condensables)

The only way to read refrigerant pressure correctly is at - Answers a stable known temperature

Air in refrigeration systems will cause - Answers higher discharge pressures
€8,31
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TutorJosh Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
342
Lid sinds
1 jaar
Aantal volgers
16
Documenten
28645
Laatst verkocht
4 dagen geleden
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3,6

53 beoordelingen

5
18
4
14
3
12
2
0
1
9

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen