100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Level 3 module 5 highlights Exam Questions And Answers 100% Guaranteed Pass.

Beoordeling
-
Verkocht
-
Pagina's
2
Cijfer
A+
Geüpload op
15-01-2025
Geschreven in
2024/2025

Level 3 module 5 highlights Exam Questions And Answers 100% Guaranteed Pass. Types of fault current include the following - AnswerOverloads, short circuits, ground faults, and arc faults. Continuous overloads can result from defective motors, overloaded equipment, or - Answertoo many loads on one circuit. NEC section 110.9 states that equipment intended to interrupt current at fault levels (fuses and circuit breakers) shall have an interrupting eating at nominal circuit voltage at least - AnswerEqual to the current that is available at the line terminals of the equipment. A ground fault is an unintentional conducting connection between any of the conductors of an electrical system and the conducting material that encloses the conductors or any conducting material, - AnswerSuch as a metal enclosure, that is grounded or may become grounded. For 480V circuits, however, the arc current may be as low as 38% of the available bolted fault current and seldom exceeds - Answer60%. Worn motor bearings are most likely to result in a - AnswerContinuous overload. The voltage rating of a fuse must be at least equal to or - Answergreater than the circuit voltage. Dual element time delay fuses are often applied in circuits subject to temporary motor overloads and - AnswerSurge curren

Meer zien Lees minder
Instelling
ELECTRICAL
Vak
ELECTRICAL








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
ELECTRICAL
Vak
ELECTRICAL

Documentinformatie

Geüpload op
15 januari 2025
Aantal pagina's
2
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

©THEBRIGHT 2024/2025 ALL RIGHTS RESERVED.




Level 3 module 5 highlights Exam Questions
And Answers 100% Guaranteed Pass.

Types of fault current include the following - Answer✔Overloads, short circuits, ground faults,
and arc faults.
Continuous overloads can result from defective motors, overloaded equipment, or - Answer✔too
many loads on one circuit.
NEC section 110.9 states that equipment intended to interrupt current at fault levels (fuses and
circuit breakers) shall have an interrupting eating at nominal circuit voltage at least -
Answer✔Equal to the current that is available at the line terminals of the equipment.
A ground fault is an unintentional conducting connection between any of the conductors of an
electrical system and the conducting material that encloses the conductors or any conducting
material, - Answer✔Such as a metal enclosure, that is grounded or may become grounded.
For 480V circuits, however, the arc current may be as low as 38% of the available bolted fault
current and seldom exceeds - Answer✔60%.

Worn motor bearings are most likely to result in a - Answer✔Continuous overload.

The voltage rating of a fuse must be at least equal to or - Answer✔greater than the circuit
voltage.
Dual element time delay fuses are often applied in circuits subject to temporary motor overloads
and - Answer✔Surge currents to provide both high performance short circuit and overload
protection.
the primary consideration of the Underwriters Labratories, Inc. (UL) is - Answer✔Safety.

UL class R fuses are high performance 1/10A to 600A units, - Answer✔250V and 600V having
a high degree of current limitation and a root mean square symmetrical short circuit interrupting
rate of up to 200,000A.
Overload relays are designed to withstand numerous trip and reset cycles without -
Answer✔Replacement.

Normal conditions, current bypasses the spring and - Answer✔Latching mechanism.

UL tests now include the NEMA tests - Answer✔Plus other ratings.
Each group is classified by the - Answer✔Largest ampere rating of its range.

1|Page
€7,52
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Thebright Florida State University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
178
Lid sinds
1 jaar
Aantal volgers
6
Documenten
12345
Laatst verkocht
2 dagen geleden
Topscore Emporium.

On this page, you find verified, updated and accurate documents and package deals.

3,8

35 beoordelingen

5
13
4
10
3
7
2
1
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen