FLS Modules Exam Questions and
Answers

Laproscopic instruments diameter and length ranges - Correct Answers -2-10mm, 30-
45cm

hopkins rod lens - Correct Answers -light has to travel back through the rod to capture
the image.

decreasing light in the camera for... - Correct Answers -decreasing diameter, increasing
scope angle (ie 5mm and 30 degree has less light than 10mm 0 degree)

When is zero degree scope most useful - Correct Answers -when working in a small
area directly in line with the scope and ports, like the pelvis

how to check fiber optics light connection - Correct Answers -black dots= broken fibers

why does it fog up? - Correct Answers -temperature and humidity discrepancy between
the OR and body

roedner's knot - Correct Answers -tied completely exrtraporporeally then pushed down.
used for: blood vessels, appendix, fallopian tube, cut end of cystic duct

linear staplers - Correct Answers -2-3 rows of staples on either side of knife blade
require 12 mm port generally

choice of staple height - Correct Answers -1. vascular: 2-2.5mm
2. GI tract 3-3.5 mm
3. distal stomach or thickened GI tract 4-4.5 mm

removing ports under direct lap visualization because: - Correct Answers -bleeding may
not be evident during procedure, and may not be evident externally after port is
removed.

when to use monopolar for hemostasis - Correct Answers -small vessels, slow rate of
bleeding, need a relatively dry operative field

, when to use bipolar for hemostasis - Correct Answers -larger vessels, works in wet
operative field, less lateral thermal spread, lower energy requirement

tools for defogging - Correct Answers -FRED antifog (must dry before putting back in),
put laparoscope in hot water

methods to clean a smudged lens - Correct Answers -gently wipe on clean tissue (liver,
uterus, bowel), remove scope and clean with hot water and gauze

Insufflation gas type and reasoning - Correct Answers -CO2- readily available,
inexpensive, non combustable, warmed and humidified better

high flow insufflation - Correct Answers -10 or more L per minute

preventing loss of pneumo with suctioning - Correct Answers -keep suction tip below the
fluid level

most common light source - Correct Answers -300W xenon lamp

Troubleshooting steps: gas preOP - Correct Answers -1. check that co2 tank is full
2. check co2 tank gasket is secured
3. check that spare co2 tank is available in the OR

troubleshooting steps: image - Correct Answers -1. check that the monitor is plugged in
and turned on 2. check that all cables are connected securely

troubleshooting steps: loss of working space: insufflator settings: measured pressure is
the same or higher than the preset pressure - Correct Answers -1. the patient may not
be adequately relaxed or there is a mechanical block of gas flow
2. inspect abdomen for rhythmic muscle contraction and palpate the abdomen for
firmness
3. check port valves to make sure they are open
4. check for kinks in tubing and make sure no one is standing on them

troubleshooting steps: loss of working space: insufflator settings: low pressure and high
flow rate - Correct Answers -1. there is a leak in the insufflation circuit
2. check that the tubing has not become disconnected from insufflator or port
3. check that all valves are closed
4. check all port sites for leaking co2
5. check for foley catheter bag distention or bowel distention

troubleshooting steps: loss of working space: insufflator settings: low pressure and no
flow - Correct Answers -1. make sure that the insufflator power is on
2. check gas level in the tank
€11,43
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
millyphilip West Virginia University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2827
Lid sinds
3 jaar
Aantal volgers
1957
Documenten
41807
Laatst verkocht
1 week geleden
white orchid store

EXCELLENCY IN ACCADEMIC MATERIALS ie exams, study guides, testbanks ,case, case study etc

3,7

536 beoordelingen

5
234
4
85
3
103
2
31
1
83

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen