100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Chapter 12 Test Water-Based Fire Suppression Systems Exam Q’s and A’s

Beoordeling
-
Verkocht
-
Pagina's
11
Cijfer
A+
Geüpload op
05-11-2024
Geschreven in
2024/2025

Chapter 12 Test Water-Based Fire Suppression Systems Exam Q’s and A’s

Instelling
Chapter 12
Vak
Chapter 12









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Chapter 12
Vak
Chapter 12

Documentinformatie

Geüpload op
5 november 2024
Aantal pagina's
11
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Chapter 12 Test Water-Based Fire
Suppression Systems Exam Q’s and A’s
Which operating valve is provided in automatic sprinkler systems to limit the
flow of water to one direction? (510) - -Check valves

- Which of the following is the most common method for driving a fire pump?
(535) - -Electric motor

- Which type of valve is a gate valve that has a yoke on the outside with a
threaded stem or screw? (509) - -Outside stem and yoke

- What is the purpose of fire department connections as part of automatic
sprinkler systems? (508) - -Boost the pressure of the primary water supply

- As part of the maintenance requirements of NFPA® 25, standpipe and
hose fire suppression systems must be flow and hydrostatic tested: (525) - -
every five years

- Which pressure-regulating device at a hose outlet uses a spring
mechanism that compensates for variations in pressure? (531) - -Pressure-
reducing devices

- Water-mist fire suppression systems that utilize air cylinders that have not
been discharged should be emptied and tested: (523) - -every twelve years

- Which automatic sprinkler system is continually charged with air that may
or may not be under pressure and operates when a sprinkler opens due to a
thermally sensitive device and the activation of detection devices? (506) - -
Preaction sprinkler system

- The actual hose connections of a standpipe hose valve can be located no
more than: (530) - -6 feet (1.8 m) from floor level

- Which fire protection system is considered a replacement for fixed fire
suppression systems that used halogenated hydrocarbon agents? (521) - -
Water-mist system

- Which type of standpipe fire suppression system contains water in the
system at all times and is attached to a water supply capable of supplying
the system demand at all times? (527) - -Automatic-wet

- Which type of sprinkler is a type of spray sprinkler capable of producing
characteristic large water droplets and is listed for its capability of providing

, fire control of specific high-challenge fire hazards? (513) - -Control mode
specific application

- Which valve is used to drain water from piping when pressure is relieved in
the pipe? (510) - -Drain valves

- Which fire protection system requires a proportioner? (524) - -Foam-water
system

- Which type of standpipe fire suppression system contains an empty pipe
that is connected to a permanent water supply? (529) - -Semiautomatic-dry

- Which classification of standpipe and hose systems is primarily for use by
firefighters trained in handling large handlines (2½-inch [65 mm] hose)?
(526) - -Class I

- Unless otherwise approved, spacing for sprinklers in residential systems is
a: (519) - -maximum of 144 square feet (13 m2) per sprinkler

- Which fire pump includes advantages such as the ease of installation as a
replacement pump, the compact space required for the pump, and the ease
of maintenance of the pump and driver? (534) - -Vertical inline

- For which fire pump are the impellers actually located within the water
supply source? (534) - -Vertical turbine

- What is a primary concern for residential sprinkler systems installed
according to NFPA® 13? (518) - -Life safety

- All sprinklers discharge water simultaneously in: (506) - -deluge sprinkler
systems

- Which automatic sprinkler system has the advantage of water flowing to
the sprinklers from multiple directions? (507) - -Gridded systems

- Which type of sprinkler is designed to provide increased life safety in
hotels, motels, and similar residential occupancies? (515) - -Quick-response
early suppression

- Which type of sprinkler is designed to be damage resistant with no
removable parts? (515) - -Institutional

- Which type of sprinkler is normally provided in a deluge sprinkler system?
(515) - -Open
€9,67
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
AccurateScores Not yet listed
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
552
Lid sinds
3 jaar
Aantal volgers
336
Documenten
15259
Laatst verkocht
6 dagen geleden

3,7

113 beoordelingen

5
51
4
18
3
18
2
11
1
15

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen