Why must you avoid running a refrigeration system below 14 kPa when pumping down - Answer-A slightly positive system pressure is required to prevent air infiltration This safety control device used on a centrifugal compressors allows the motor to be started unloading - Answer-Vane closed switch What is the purpose of the chilled water flow switch - Answer-Protects the chiller from freezing due to lack of waterflow Where can refrigeration system log sheets be obtained from - Answer-1. Refrigeration system manufacturers. 2. Inspection and insurance companies. 3. Developed by the refrigeration system operator. Which of the following is not a benefit of a preventative maintenance program - Answer-Allows for the accumulation of all spare parts for each piece of equipment in case of a major breakdown What is the symptom of a refrigeration system that has high suction pressure due to an oversized expansion valve - Answer-An abnormally cold suction line If the compressor fails to start but the motor is running, which of the following could be a cause - Answer-The coupling is sheared or broken Why is it recommended that a refrigeration log sheet be used - Answer-It can indicate changes in the system operation The safety control in a centrifugal compressor, which ensures the compressor will only be started under a no-load condition, it's called - Answer-Vane closed switch Which of the following steps is not a step in the start of a reciprocating or Rotary compressor refrigerating system - Answer-Valves in lines connecting suction gauges should be closed If the temperature drops 2.5 - 3°C, below the set point, this Safety control device used on a centrifugal compressor will shut down the compressor. - Answer-Chilled water low-temperature cut out Vane closed switch - Answer-Allows the motor to be started under no load

Meer zien Lees minder
Instelling
Refrigeration Machine Operator
Vak
Refrigeration machine operator








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Refrigeration machine operator
Vak
Refrigeration machine operator

Documentinformatie

Geüpload op
9 september 2024
Aantal pagina's
3
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Compression - Refrigeration System
Operations Exam Questions and
Answers
Why must you avoid running a refrigeration system below 14 kPa when pumping down -
Answer-A slightly positive system pressure is required to prevent air infiltration

This safety control device used on a centrifugal compressors allows the motor to be
started unloading - Answer-Vane closed switch

What is the purpose of the chilled water flow switch - Answer-Protects the chiller from
freezing due to lack of waterflow

Where can refrigeration system log sheets be obtained from - Answer-1. Refrigeration
system manufacturers.
2. Inspection and insurance companies.
3. Developed by the refrigeration system operator.

Which of the following is not a benefit of a preventative maintenance program - Answer-
Allows for the accumulation of all spare parts for each piece of equipment in case of a
major breakdown

What is the symptom of a refrigeration system that has high suction pressure due to an
oversized expansion valve - Answer-An abnormally cold suction line

If the compressor fails to start but the motor is running, which of the following could be a
cause - Answer-The coupling is sheared or broken

Why is it recommended that a refrigeration log sheet be used - Answer-It can indicate
changes in the system operation

The safety control in a centrifugal compressor, which ensures the compressor will only
be started under a no-load condition, it's called - Answer-Vane closed switch

Which of the following steps is not a step in the start of a reciprocating or Rotary
compressor refrigerating system - Answer-Valves in lines connecting suction gauges
should be closed

If the temperature drops 2.5 - 3°C, below the set point, this Safety control device used
on a centrifugal compressor will shut down the compressor. - Answer-Chilled water low-
temperature cut out

Vane closed switch - Answer-Allows the motor to be started under no load
€9,72
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
lectknancy Boston University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
285
Lid sinds
2 jaar
Aantal volgers
28
Documenten
26010
Laatst verkocht
4 dagen geleden

3,6

57 beoordelingen

5
23
4
10
3
11
2
3
1
10

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen