100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Fire Pump Run Test Practice Quiz with 100% Correct Answers

Beoordeling
-
Verkocht
-
Pagina's
8
Cijfer
A+
Geüpload op
29-08-2024
Geschreven in
2024/2025

Fire Pump Run Test Practice Quiz with 100% Correct Answers Heat exchangers shall be checked for __________ water flow. - Answer️️ - cooling All alarm pilot lights should be in what state? - Answer️️ -Off There are two requirements listed under pump house conditions: - Answer️️ -Ventilating louvers are free to operate & Heat is adequate, at least 40°F for diesel pump rooms __________ inspection requires verification that the pump suction discharge and bypass valves should be fully open. - Answer️️ -Weekly When verifying the electrical system conditions, the controller pilot should be: - Answer️️ -Illuminated (power on) Pump packing boxes, bearings and casing shall be checked for __________. - Answer️️ -overheating What kind of pump do you record the time crank? - Answer️️ -Diesel The pertinent visual observation categories required to be inspected weekly checklists are: - Answer️️ -Pump house conditions, pump system ©SOPHIABENNETT@ Saturday, August 24, 2024 8:52 AM 2 conditions, electrical system conditions, diesel engine system conditions, steam engine conditions What is the purpose of inspecting the pump assembly? - Answer️️ -To confirm it appears to be in operating condition and is free from physical damage True or False? The transfer switch normal pilot light should be illuminated. - Answer️️ - True The purpose of testing the pump assembly is to ensure automatic manual operation upon demand and continuous delivery of the required system output. An additional purpose is to __________. - Answer️️ -detect deficiencies not evident by inspection At what level should the oil level in the vertical motor sight glass be? - Answer️️ -Normal/Acceptable range True or False? The isolating switch for electric pumps should be closed. - Answer️️ -True True or False? ©SOPHIABENNETT@ Saturday, August 24, 2024 8:52 AM 3 When verifying water level in suction reservoir during weekly inspection, the water level should be full. - Answer️️ -True Diesel engine fuel tank level, float switch and solenoid valve operation shall be checked __________. - Answer️️ -weekly (visual inspection) Controllers include air-, __________ or electric- operated units. - Answer️️ -hydraulic- The weekly test pertinent adjustments shall be made while the pump is: - Answer️️ -running True or False? The oil level in the right angle gear drive should be normal/acceptable range. - Answer️️ -True The normal phase rotation pilot should be: - Answer️️ -on The reverse phase alarm pilot light for electric pumps should be: - Answer️️ -off The controller selector switch should be in the __________ position. - Answer️️ -auto The number of engine operating hours is measured by the: - Answer️️ - engine running time meter ©SOPHIABENNETT@ Saturday, August 24, 2024 8:52 AM 4 Types of centrifugal fire pumps include __________ and __________ units of __________ and __________ shaft design. - Answer️️ -single and multistage; horizontal and vertical True or False? The fire pump shall be started manually for the test run. - Answer️️ -False Diesel fire pumps are required to be test ran weekly for __________ minutes. - Answer️️ -30 A valve installed as a safety valve shall: - Answer️️ -permit to

Meer zien Lees minder
Instelling
Fire Pump
Vak
Fire Pump









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Fire Pump
Vak
Fire Pump

Documentinformatie

Geüpload op
29 augustus 2024
Aantal pagina's
8
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

©SOPHIABENNETT@2024-2025 Saturday, August 24, 2024 8:52 AM



Fire Pump Run Test Practice Quiz with
100% Correct Answers

Heat exchangers shall be checked for __________ water flow. - Answer✔️✔️-
cooling

All alarm pilot lights should be in what state? - Answer✔️✔️-Off

There are two requirements listed under pump house conditions: -
Answer✔️✔️-Ventilating louvers are free to operate

&

Heat is adequate, at least 40°F for diesel pump rooms

__________ inspection requires verification that the pump suction
discharge and bypass valves should be fully open. - Answer✔️✔️-Weekly

When verifying the electrical system conditions, the controller pilot should
be: - Answer✔️✔️-Illuminated (power on)

Pump packing boxes, bearings and casing shall be checked for __________.
- Answer✔️✔️-overheating

What kind of pump do you record the time crank? - Answer✔️✔️-Diesel

The pertinent visual observation categories required to be inspected
weekly checklists are: - Answer✔️✔️-Pump house conditions, pump system




1

, ©SOPHIABENNETT@2024-2025 Saturday, August 24, 2024 8:52 AM


conditions, electrical system conditions, diesel engine system conditions,
steam engine conditions

What is the purpose of inspecting the pump assembly? - Answer✔️✔️-To
confirm it appears to be in operating condition and is free from physical
damage

True or False?



The transfer switch normal pilot light should be illuminated. - Answer✔️✔️-
True

The purpose of testing the pump assembly is to ensure automatic manual
operation upon demand and continuous delivery of the required system
output. An additional purpose is to __________. - Answer✔️✔️-detect
deficiencies not evident by inspection

At what level should the oil level in the vertical motor sight glass be? -
Answer✔️✔️-Normal/Acceptable range

True or False?



The isolating switch for electric pumps should be closed. - Answer✔️✔️-True

True or False?




2
€8,77
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
SophiaBennett Howard Community College
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
130
Lid sinds
1 jaar
Aantal volgers
5
Documenten
8567
Laatst verkocht
2 weken geleden
EXAM GAME-CHANGER

Exam Questions and Answers Section : Study Like a Pro, Study Smart, Study with Sophia.

3,7

26 beoordelingen

5
10
4
5
3
7
2
1
1
3

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen