100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

559 Journeyman Mechanical Exam HVAC Complete Questions and Answers

Beoordeling
-
Verkocht
-
Pagina's
4
Cijfer
A+
Geüpload op
19-05-2024
Geschreven in
2023/2024

559 Journeyman Mechanical Exam HVAC Complete Questions and Answers Which Type of air-conditoning system is most likely to leak refrigerant into a structure? Direct, Indirect, Evaporative or Split? - CORRECT ANSWER-Direct : 2015 IMC 1103.3.2 When mechanical equipment is located on a flat roof that is more than 30 inches above grade, how far from the roofs edge must the equipment be located before a guard rail is not needed? less than 6', 9', 4' or more than 10'? - CORRECT ANSWER-More than 10' - 2015 IMC 304.11 A mall bathroom exhaust outlet shall terminate a minimum height of ____ feet above an adjoining sidewalk? - CORRECT ANSWER-10 feet above adjoining grade - 2015 IMC 501.3.1 A room that measures 10x20x8 contains a 35,000 BTU wood burning stove in a building classified as unusually tight construction, what size combustions air openings will be required if they are installed directly in a side wall? - CORRECT ANSWER-8.7 square inches (1 square inch per 4,000 BTU) - 2015 IFGC 304.6.1 How many BTUs in one ton of refrigeration? - CORRECT ANSWER-12,000 BTUS - 2015 IMC Definitions p. 17 'Refrigeration Capacity Rating.' Which refrigerant is not classified as a flammable refrigerant? - CORRECT ANSWERClass 1 - 2015 IMC Definitions p. 13 'Flammability Classifications' Grounded circuit conductor shall be identified by a covering or marking by which of the following colors: A) White or Gray B) Green, C) Black or D) Red? - CORRECT ANSWER-White or Gray - 2014 NEC 200.6 What is the minimum distance to a property line that a supply air intake can be located? - CORRECT ANSWER-10' - 2015 IMC 401.4 How many pounds per 1,000 cubic feet of occupied space of R-410A refrigerant can be in a direct system? - CORRECT ANSWER-26 pounds - 2015 IMC Table 1103.1 Which of the following systems is required by code to be periodically tested per the manufacturer's instructions and as required by the code official: Fuel Gas Piping, Venting Systems, Air duct systems or Refrigerant Alarm Systems? - CORRECT ANSWER-Refrigerant Alarm Systems - 2015 IMC 1109.1 A room contains a gas-fired furnace with an input rating of 108,000 BTUs. The room is 20'x10'x8'. Is the room classified as a confined space? Yes or no. - CORRECT ANSWER-Yes (Needs to be 50 cubic feet per 1,000 BTU) - 2015 IFGC 304.51 What is the full load current rating of a 230-volt, three phase alternating current motor rated at 7.5 horsepower? - CORRECT ANSWER-22 amps - 2014 NEC Table 430.250 (Motors, Motor Circuits and Controllers) p. 70-351 What is the maximum flame spread and smoke development ratings for duct covering insulation in an assembly occupancy? - CORRECT ANSWER-25 flame spread, 50 smoke development ratings - 2015 IMC 604.3 For a duct to penetrate a fire partition without the installation of a fire damper the partition opening must be lined with a steel sleeve of what thickness? - CORRECT ANSWER-.060-inch-thick - 2015 IMC 607.5.3 Fire dampers shall comply with the requirements of what standard for testing? - CORRECT ANSWER-UL 555 - 2015 IMC 607.3.1 What size copper conductor is required for a branch circuit using type THHW 75°C conductor installed in a racewa

Meer zien Lees minder
Instelling
Hvac
Vak
Hvac








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Hvac
Vak
Hvac

Documentinformatie

Geüpload op
19 mei 2024
Aantal pagina's
4
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€10,10
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
StudyCenter1 Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
221
Lid sinds
2 jaar
Aantal volgers
91
Documenten
3854
Laatst verkocht
1 week geleden
Nursing school is hard! Im here to simply the information and make it easier!

My mission is to be your LIGHT in the dark. If you"re worried or having trouble in nursing school, I really want my notes to be your guide! I know they have helped countless others get through and thats all i want for YOU! Stay with me and you will find everything you need to study and pass any tests,quizzes abd exams!

4,3

27 beoordelingen

5
18
4
4
3
3
2
0
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen