Fire Alarm TFM12

What does PLFA stand for? - ANSPower Limited Fire Alarm

What does NPLFA stand for? - ANSNon Power Limited Fire Alarm

What material must NPLFA circuit conductors be made from - ANSOnly solid or
stranded copper is permitted

What is a single station detector? - ANSBattery powered smoke detectors that do not
communicate off premises.

What is a multiple station detector? - ANSMains powered smoke detectors with battery
backup that are linked together, so that if one unit initiates, alarms in all detectors will
sound. They do not communicate off premises.

How frequently must household single and multiple single station detectors be
inspected and tested? - ANSIn accordance with the manufactures recommendations, at
least monthly.

How frequently must household single and multiple station detectors be inspected and
tested? - ANSAt least 3 years, by a qualified service technician.

How frequently must heat detectors be tested? - ANSTwo or more annually, different
detectors must be tested each year, and within 5 years all detectors must have been
tested.

What does "restorable" mean? - ANSThe detector can be "restored" or "reused" after it
has initiated.

What does "non-restorable" mean? - ANSThe detector cannot be 're-used" after it has
initiated an alarm. (Think of a heat detector, which self destructs upon initiating.)

What size conductors are permitted? - ANSSize 18 AWG and 16 AWG are permitted,
provided they do not exceed certain rated ampacities

What is used to protect transformers or other devices supplied from power-supply
conductors? - ANSAn overcurrent device not rated over 20 Amperes

, When located within 7ft of the floor, how shall cables be fastened? - ANSCables shall
be fastened in an approved manner at intervals of not more than 18 inches.

Single conductors shall not be smaller that ___ AWG? - ANS18

Conductors of 26AWG shall only be permitted in which circumstances? - ANSWhere
spliced with a connector listed as suitable for 26 to 24 AWG.

How should PLFA conductors NOT be installed? - ANSPLFA conductors shall not be
strapped, taped or attached to the exterior of any conduit or raceway.

What is Plenum cable? What are its characteristics? - ANSCable that can be installed in
ducts, plenums or other spaces used for environment air. It has adequate fire resistance
and low smoke-producing characteristics.

What is riser cable? What are its characteristics? - ANSCable to be used in vertical wire
runs in shafts or between floors. Not to be used where Plenum cable is required. It is
capable of preventing fire from rising form floor-to-floor.

What is Genral Purpose Cable? What are its characteristics? - ANSCable for general
purpose fire alarm use. Not to be used where Plenum or Riser cable is required. It is
resistant to the spread of fire.

What type shall plenum cable be? What substitutions are allowed? - ANSPower Limited
Fire Alarm Plenum (FPLP) CMP can be substituted.

What type shall riser wire be? What substitutions are permitted? - ANSPower Limited
Fire Alarm Riser (FPLR) CMP,FPLP,CMR can be substituted.

What type shall general purpose wire be? What substitutions are permitted? -
ANSPower Limited Fire Alarm (FPL) CMP,FPLP,CMR,FPLR,CMG, and CM can be
substituted. (All types)

What is the maximum voltage permitted through multi-conductor NPLFA cables? -
ANS150 volts

What is the voltage rating of PLFA cables? - ANSNot less than 300 volts
€11,93
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Ashley96 Howard Community College
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
590
Lid sinds
2 jaar
Aantal volgers
198
Documenten
5001
Laatst verkocht
1 week geleden

In my page you will find all latest Exams , with Questions and Answers, package deals, etc. I upload quality. Instant delivery. You will get solutions to all subjects in both assignments and major exams. Contact me for any assistance. Good Luck!!!

4,0

156 beoordelingen

5
88
4
21
3
25
2
6
1
16

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen