Relays are employed in a power system network to ensure that the system operates safely, reliably, and conveniently. The Over-Current relay is commonly utilized in the power system to prevent against short circuits and incorrect system settings. In the power system, an incorrectly set Over-Current relay makes it harder to send the trip signal. As a result, it must be carefully linked in the power system. As a result, it is critical to certify the installation of power protection equipment. The operation of over-current relays, such as instantaneous over-current relays, definite time over-current relays, and inverted definite time over-current relays, is described in this work. A power system network was modelled using the Matlab/Simulink package to quantify the performance of over-current relays using the instantaneous over-current relay. A three-phase 132 kV at 50 Hz source, a 132/11 kV step down transformer, and a single parallel RLC load with active and reactive power of 50 MW and 25 Mvar respectively made up the power system network. The Matlab/Simulink package was used to create the relay block, which had a current setting of 125 percent, a CT of 400/5, a pickup current of 6.25 A, and a time multiplier setting of 0.6. A second RLC parallel load was connected to the network to quantify the relay's performance. The load's active and reactive power were set to 0.3 kW and 0.3 kVar, respectively, and the measured output current was 5.18 A, which was below the pickup current and the relay did not send a trip signal to the circuit breaker. Another parallel RLC load was connected to the network, with the active and reactive power of the first two loads set to 50 kW and 20 kVar, respectively, and the third load's active and reactive power set to 50 MW and 20 Mvar. The output current was measured at 69.5 kA, which is significantly higher than the pickup current, thus the relay detected the problem and sent a trip signal to the circuit breaker.

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

SCHOOL OF ELECTRICAL, ELECTRONIC AND COMPUTER ENGINEERING




Power Systems 2
(ENEL4WA)
Assignment 2 – Over Current Protection Using
Instantaneous Overcurrent Relay


NOTE// IF YOU NEED SIMULATION FILE EMAIL ME
AT:

,Abstract
Relays are employed in a power system network to ensure that the system operates safely, reliably,
and conveniently. The Over-Current relay is commonly utilized in the power system to prevent
against short circuits and incorrect system settings. In the power system, an incorrectly set Over-
Current relay makes it harder to send the trip signal. As a result, it must be carefully linked in the
power system. As a result, it is critical to certify the installation of power protection equipment. The
operation of over-current relays, such as instantaneous over-current relays, definite time over-current
relays, and inverted definite time over-current relays, is described in this work. A power system
network was modelled using the Matlab/Simulink package to quantify the performance of over-
current relays using the instantaneous over-current relay. A three-phase 132 kV at 50 Hz source, a
132/11 kV step down transformer, and a single parallel RLC load with active and reactive power of
50 MW and 25 Mvar respectively made up the power system network. The Matlab/Simulink package
was used to create the relay block, which had a current setting of 125 percent, a CT of 400/5, a pickup
current of 6.25 A, and a time multiplier setting of 0.6. A second RLC parallel load was connected to
the network to quantify the relay's performance. The load's active and reactive power were set to 0.3
kW and 0.3 kVar, respectively, and the measured output current was 5.18 A, which was below the
pickup current and the relay did not send a trip signal to the circuit breaker. Another parallel RLC
load was connected to the network, with the active and reactive power of the first two loads set to 50
kW and 20 kVar, respectively, and the third load's active and reactive power set to 50 MW and 20
Mvar. The output current was measured at 69.5 kA, which is significantly higher than the pickup
current, thus the relay detected the problem and sent a trip signal to the circuit breaker.




Page | i

, Table of Contents
Abstract..................................................................................................................................................i
Table of figures.....................................................................................................................................iii
Nomenclature........................................................................................................................................v
1. Introduction.......................................................................................................................................1
2. Theoretical Background.....................................................................................................................2
2.1. Fault and its clarification.............................................................................................................2
2.1.1. Symmetrical faults...............................................................................................................2
2.1.2. Unsymmetrical faults...........................................................................................................2
2.2. Requirements of a protection system.........................................................................................2
2.2.1. Reliability.............................................................................................................................2
2.2.2. Selectivity.............................................................................................................................2
2.2.3. Sensitivity.............................................................................................................................2
2.2.4. Speed...................................................................................................................................3
2.2.5. Simplicity..............................................................................................................................3
2.2.6. Economy..............................................................................................................................3
2.3. Protection using relay.................................................................................................................3
2.4. Overcurrent Relay.......................................................................................................................3
2.5. Types of overcurrent relays........................................................................................................4
2.5.1. Instantaneous Overcurrent Relay........................................................................................4
2.5.2. Definite Time Overcurrent Relay..........................................................................................4
2.5.3. Inverse Definite Minimum Time (IDMT) Overcurrent Relay.................................................5
3. Simulations........................................................................................................................................6
3.1. Part 1 – Source, transformer and load voltage and current measurements...............................6
3.1.1. Source..................................................................................................................................7
3.1.2. Transformer.........................................................................................................................8
3.1.3. Load...................................................................................................................................10
3.2. Part 2 - Instantaneous relay block diagram...............................................................................11
3.3. Part 3 – Connecting 2nd load with no over current condition....................................................14
3.4. Part 4- Connecting 3rd load with over-current condition...........................................................15
4. Results discussion and analysis........................................................................................................17
4.1. Part 1 - Source, transformer and load voltage and current measurements..............................17
4.1.1. Source................................................................................................................................17


Page | ii

Geschreven voor

Instelling
Vak

Documentinformatie

Geüpload op
29 augustus 2022
Aantal pagina's
25
Geschreven in
2021/2022
Type
OVERIG
Persoon
Onbekend

Onderwerpen

€7,99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kan je een ander document kiezen. Je kan het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
nkanyisontombela

Maak kennis met de verkoper

Seller avatar
nkanyisontombela UKZN
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
3 jaar
Aantal volgers
1
Documenten
13
Laatst verkocht
3 jaar geleden

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen